Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
1TAE1 Grainger |
![Подробнее...](http://img.ros-master.ru/1/tnail/1TAE1.JPG) |
Heat Sequencer, Universal, Number of Switches 1, Main Switch On Time 1 to 20 Sec, Main Switch Off Time 4 to 110 Sec, Number of Timings 1, Height 2 In, Width 3 In, Depth 3 In, Off Time 4 to 110 Seconds, On Time 1 to 20 Seconds, Control Volts 24, Pilot Duty 120/480V 125 VA, Includes 1/4 In Spade Terminal Connections |
HONEYWELL R24AA1008 |
1TAE4 Grainger |
![Подробнее...](http://img.ros-master.ru/1/tnail/1TAE1.JPG) |
Heat Sequencer, Universal, Number of Switches 2, Main Switch On Time 1 to 20 Sec, Main Switch Off Time 40 to 110 Sec, Number of Timings 1, Height 2 In, Width 2 In, Depth 3 In, Off Time 40 to 110 Seconds, On Time 1 to 20 Seconds, Control Volts 24, Pilot Duty 120/480V 125 VA, Includes 1/4 In Spade Terminal Connections |
HONEYWELL R24BA1006 |
2E607 Grainger |
![Подробнее...](http://img.ros-master.ru/2/tnail/2E608.JPG) |
Fan/Heat Sequencer, Off Time 1-110 Seconds, On Time 1-110 Seconds, Number of Timings 2, Number of Switches 3, Inductive Full Load Current @ 480 VAC 3 Amps, Inductive Full Load Current @ 120 VAC 10 Amps, Inductive Full Load Current @ 240 VAC 5 Amps, Locked Rotor Current @ 120 VAC 60 Amps, Locked Rotor Current @ 240 VAC 30 Amps, Locked Rotor Current @ 480 VAC 18 Amps, Contact Current Rating Resistive @ 120VAC 25 Amps, Contact Current Rating Resistive @ 240VAC 25 Amps |
WHITE-RODGERS 24A34-5 |
2FBV7 Grainger |
![Подробнее...](/img/s_noimage.gif) |
Sequencer, Heating Elements/Blower Motor, Number of Switches 1, Main Switch On Time 30-90 Sec, Main Switch Off Time 1-30 Sec, Number of Timings 1, Height 2 1/2 In, Width 3 In, Depth 3 3/4 In, Control Volts 24, Includes Double Quick-Connect Terminals For Combination Loads |
SUPCO Q102 |
2FBV8 Grainger |
![Подробнее...](http://img.ros-master.ru/2/tnail/2FBV6.JPG) |
Sequencer, Heating Elements/Blower Motor, Number of Switches 2, Main Switch On Time 1-20 Sec, Main Switch Off Time 40-110 Sec, Number of Timings 1, Height 2 1/2 In, Width 3 In, Depth 3 3/4 In, Aux Switch Off Time 40-110 Sec, Aux Switch On Time 1-20 Sec, Control Volts 24, Includes Double Quick-Connect Terminals For Combination Loads |
SUPCO Q103 |
2FBW1 Grainger |
![Подробнее...](http://img.ros-master.ru/2/tnail/2FBV6.JPG) |
Sequencer, Heating Elements/Blower Motor, Number of Switches 3, Main Switch On Time 1-110 Sec, Main Switch Off Time 1-110 Sec, Number of Timings 2, Height 2 1/2 In, Width 3 In, Depth 3 3/4 In, Aux Switch Off Time 1-110 Sec, Aux Switch On Time 1-110 Sec, Control Volts 24, Includes Double Quick-Connect Terminals For Combination Loads |
SUPCO Q105 |
2FBW3 Grainger |
![Подробнее...](http://img.ros-master.ru/2/tnail/2FBV6.JPG) |
Sequencer, Heating Elements/Blower Motor, Number of Switches 1, Main Switch On Time 1-25 Sec, Main Switch Off Time 65-115 Sec, Number of Timings 1, Height 2 1/2 In, Width 3 In, Depth 3 3/4 In, Aux Switch Off Time 65-115 Sec, Aux Switch On Time 1-25 Sec, Control Volts 24, Includes Double Quick-Connect Terminals For Combination Loads |
SUPCO Q108 |
6UEE4 Grainger |
![Подробнее...](http://img.ros-master.ru/6/tnail/6UEE4.JPG) |
Electric Sequencer, Strip Heat And/Or Blower Fan In Heat Pumps And Electric Furnaces, Number of Switches 1, Main Switch On Time (Sec.) 1 to 25, Main Switch Off Time (Sec.) 65 to 115, Number of Timings 1, Height (In.) 2-1/2, Width (In.) 1-3/4, Depth (In.) 1-1/2307Aux. Switch Off Time (Sec.) 1 to 25, Aux. Switch On Time (Sec.) 65 to 11542Off Time (Seconds) 65 to 115, On Time (Seconds) 1 to 25, Control Volts 24 |
GRAINGER APPROVED VENDOR 6UEE4 |
6UEE5 Grainger |
![Подробнее...](http://img.ros-master.ru/6/tnail/6UEE5.JPG) |
Electric Sequencer, Number of Switches 1, Number of Timings 1, Height (In.) 1-1/2, Width (In.) 1-5/8, Depth (In.) 1-5/8, Resistive Amps @ 240V 30, Full Load Amps @ 240VAC 7, Off Time (Seconds) 1 to 30, On Time (Seconds) 30 to 90, Control Volts 24, Pilot Duty 120/480V (VA) 125, Includes Double Quick Connect Terminals for Combination Load |
GRAINGER APPROVED VENDOR 6UEE5 |
6UEE6 Grainger |
![Подробнее...](http://img.ros-master.ru/6/tnail/6UEE6.JPG) |
Electric Sequencer, Number of Switches 1, Number of Timings 1, Height (In.) 1-1/2, Width (In.) 1-5/8, Depth (In.) 1-5/8, Resistive Amps @ 240V 30, Full Load Amps @ 240VAC 7, Off Time (Seconds) 40 to 110, On Time (Seconds) 1 to 20, Control Volts 24, Pilot Duty 120/480V (VA) 125, Includes Double Quick Connect Terminals for Combination Load |
GRAINGER APPROVED VENDOR 6UEE6 |