Blower, Inline Duct
Inline Belt Drive Duct Blower, Wheel Diameter 12-7/8 Inches, Height 23 Inches, Width 27 Inches, Depth 27 1/2 Inches, Without Motor And Drives, Recommended Motor Power Range 1/3 Thru 1 HP, Maximum Ambient Temperature 40 Degrees C, Uses Optional 3F540 Filter Rack
Артикул:
3F534
Каталог:
Grainger
Производитель:
DELHI
Номер модели:
212 INSL
Страна производства:
Canada
Вес (кг):
40.45
Спецификация:
Item: Blower |
Type: Less Drive Package |
Wheel Dia. (In.): 12-7/8 |
CFM Range: 2192 to 3490 @ 0.0" SP |
Max. Ambient Temp. (F): 140 |
Max. Inlet Temp. (Deg. F): 140 |
Motor HP Range: 1/3 to 1 |
RPM Range: 544 to 795 |
Bearing Type: Ball |
Height (In.): 23 |
Width (In.): 27 |
Max. Depth (In.): 27-1/2 |
Discharge Height (In.): 13-7/16 |
Discharge Width (In.): 15-5/8 |
Number of Mounting Points: 4 |
Bolt Hole Dia. (In.): 7/8 |
Mounting Position: All With Shaft Horizontal |
Wheel Type: Forward Curve |
Wheel Material: Steel |
Shaft Dia. (In.): 3/4 |
Housing Material: Steel |
Housing Finish: Green Baked Enamel |
Filter Height (In.): 21 3/4 |
Filter Width (In.): 25 7/8 |
Filter Factor: 0.020 |
Filter Rack Stock No.: 3F540 |
Дополнительные аксессуары: |
Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
3F540 Grainger |
 |
Filter Rack, Overall Height 23 Inches, Overall Width 27 Inches, Overall Depth Including Flanges 4 Inches, Filter Factor 0.020, Filter Height 21 3/4 Inches, Filter Width 25 7/8 Inches, Drawer Type, For Use With 3F534 Inline Duct Blower |
DELHI F212A |
4PU53 Grainger |
 |
Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 125/52 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire |
DAYTON 4PU53 |
4PU54 Grainger |
 |
Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 165/74 F/C, Temp Differential 25 F, Full Load Amps @120V 9.8, @240V 4.9, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire |
DAYTON 4PU54 |
4PU55 Grainger |
 |
Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 200/93 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire |
DAYTON 4PU55 |