ТЕЛ:+7 (985) 487-07-35
WhatsApp / Telegram: +7 (916) 211-71-00
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Blower, Inline Duct

Inline Belt Drive Duct Blower, Wheel Diameter 12-7/8 Inches, Height 23 Inches, Width 27 Inches, Depth 27 1/2 Inches, Without Motor And Drives, Recommended Motor Power Range 1/3 Thru 1 HP, Maximum Ambient Temperature 40 Degrees C, Uses Optional 3F540 Filter Rack
Артикул:
3F534
Каталог:
Grainger
Производитель:
DELHI
Номер модели:
212 INSL
Страна производства:
Canada
Вес (кг):
40.45
3F534 Blower, Inline Duct
Спецификация:
Item: Blower
Type: Less Drive Package
Wheel Dia. (In.): 12-7/8
CFM Range: 2192 to 3490 @ 0.0" SP
Max. Ambient Temp. (F): 140
Max. Inlet Temp. (Deg. F): 140
Motor HP Range: 1/3 to 1
RPM Range: 544 to 795
Bearing Type: Ball
Height (In.): 23
Width (In.): 27
Max. Depth (In.): 27-1/2
Discharge Height (In.): 13-7/16
Discharge Width (In.): 15-5/8
Number of Mounting Points: 4
Bolt Hole Dia. (In.): 7/8
Mounting Position: All With Shaft Horizontal
Wheel Type: Forward Curve
Wheel Material: Steel
Shaft Dia. (In.): 3/4
Housing Material: Steel
Housing Finish: Green Baked Enamel
Filter Height (In.): 21 3/4
Filter Width (In.): 25 7/8
Filter Factor: 0.020
Filter Rack Stock No.: 3F540

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
3F540
Grainger
Подробнее... Filter Rack, Overall Height 23 Inches, Overall Width 27 Inches, Overall Depth Including Flanges 4 Inches, Filter Factor 0.020, Filter Height 21 3/4 Inches, Filter Width 25 7/8 Inches, Drawer Type, For Use With 3F534 Inline Duct Blower DELHI
F212A
4PU53
Grainger
Подробнее... Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 125/52 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU53
4PU54
Grainger
Подробнее... Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 165/74 F/C, Temp Differential 25 F, Full Load Amps @120V 9.8, @240V 4.9, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU54
4PU55
Grainger
Подробнее... Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 200/93 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU55
Обратите внимание:
3F533
Blower, Inline Duct
7H716
Blower, Inline Duct
7H720
Blower, Inline Duct
7H743
Blower, Inline Duct