Blower, Inline Duct
Inline Belt Drive Duct Blower, Wheel Diameter 11-1/8 Inches, Height 20 Inches, Width 22 1/4 Inches, Depth 24 3/4 Inches, Without Motor And Drives, Recommended Motor Power Range 1/4 Thru 3/4 HP, Maximum Ambient Temperature 40 Degrees C, Uses Optional 3F539 Filter Rack
Артикул:
3F533
Каталог:
Grainger
Производитель:
DELHI
Номер модели:
210 INSL
Страна производства:
Canada
Вес (кг):
31.36
Спецификация:
Item: Blower |
Type: Less Drive Package |
Wheel Dia. (In.): 11-1/8 |
CFM Range: 1725 to 2515 @ 0.0" SP |
Max. Ambient Temp. (F): 140 |
Max. Inlet Temp. (Deg. F): 140 |
Motor HP Range: 1/4 to 3/4 |
RPM Range: 625 to 863 |
Bearing Type: Ball |
Height (In.): 20 |
Width (In.): 22-1/4 |
Max. Depth (In.): 24-3/4 |
Discharge Height (In.): 11-3/8 |
Discharge Width (In.): 13-1/8 |
Number of Mounting Points: 4 |
Bolt Hole Dia. (In.): 7/8 |
Mounting Position: All With Shaft Horizontal |
Wheel Type: Forward Curve |
Wheel Material: Steel |
Shaft Dia. (In.): 3/4 |
Housing Material: Steel |
Housing Finish: Green Baked Enamel |
Filter Height (In.): 18 3/4 |
Filter Width (In.): 21 1/8 |
Filter Factor: 0.038 |
Filter Rack Stock No.: 3F539 |
Дополнительные аксессуары: |
Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
3F539 Grainger |
 |
Filter Rack, Overall Height 20 Inches, Overall Width 22 1/4 Inches, Overall Depth Including Flanges 4 Inches, Filter Factor 0.038, Filter Height 18 3/4 Inches, Filter Width 21 1/8 Inches, Drawer Type, For Use With 3F533 Inline Duct Blower |
DELHI F210A |
4PU53 Grainger |
 |
Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 125/52 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire |
DAYTON 4PU53 |
4PU54 Grainger |
 |
Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 165/74 F/C, Temp Differential 25 F, Full Load Amps @120V 9.8, @240V 4.9, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire |
DAYTON 4PU54 |
4PU55 Grainger |
 |
Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 200/93 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire |
DAYTON 4PU55 |