Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
5KPE1 Grainger |
|
Single Piece Air Handler, Upflow/Horizontal, Nominal Capacity 2 Tons, Rated CFM @ 05 (in WC) High 1208, Voltage 230, 60 Hz, 1 Phase, Overall Dimensions H 48 x, W 21 x, D 21 In, Supply Opening W 12 1/2 x, D 19 x, Return Air Opening W 19 x, D 19 In, Use with Heater sizes 0 to 10 KW, Liquid Line 3/8 In, Suction Line 3/4 In, Max Fuse Size 10 Amp Without Heater Kit, Min Circuit Amps 5.4 Without Heater Kit, Filter Size 16 x 20, Includes Evaporator Coil And R410A TXV Metering Device |
COMFORT-AIRE HAGV24-00-1A |
5KPE2 Grainger |
|
Single Piece Air Handler, Upflow/Horizontal, Nominal Capacity 3 Tons, Rated CFM @ 05 (in WC) High 1208, Voltage 230, 60 Hz, 1 Phase, Overall Dimensions H 48 x, W 21 x, D 21 In, Supply Opening W 12 1/2 x, D 19 x, Return Air Opening W 19 x, D 19 In, Use with Heater sizes 0 to 15 KW, Liquid Line 3/8 In, Suction Line 3/4 In, Max Fuse Size 10 AMP Without Heater Kit, Min Circuit Amps 5.4 Without Heater Kit, Filter Size 16 x 20, Includes Evaporator Coil And R410A TXV Metering Device |
COMFORT-AIRE HAGV36-00-1A |
5KPE3 Grainger |
|
Single Piece Air Handler, Upflow/Horizontal, Nominal Capacity 4 Tons, Rated CFM @ 05 (in WC) High 1761, Voltage 230, 60 Hz, 1 Phase, Overall Dimensions H 58 3/4 x, W 24 1/2 x, D 21 3/4 In, Supply Opening W 21 1/4 x, D 23 3/8 In, Return Air Opening W 22 1/2 x, D 19 3/4 In, Heater sizes 0 to 20 KW, Liquid Line 3/8 In, Suction Line 7/8 In, Max Fuse Size 15 AMP Without Heater Kit, Min Circuit Amps 8.5 Without Heater Kit, Filter Size 16 x 20, Includes Evaporator Coil And R410A TXV Metering Device |
COMFORT-AIRE HAGV48-00-1A |
5KPE4 Grainger |
|
Single Piece Air Handler, Upflow/Horizontal, Nominal Capacity 5 Tons, Rated CFM @ 05 (in WC) High 1761, Voltage 230, 60 Hz, 1 Phase, Overall Dimensions H 58 3/4 x, W 24 1/2 x, D 21 3/4 In, Supply Opening W 21 1/4 x, D 23 3/8 In, Return Air Opening W 22 1/2 x, D 19 3/4 In, Heater sizes 0 to 20 KW, Liquid Line 3/8 In, Suction Line 7/8 In, Max Fuse Size 15 AMP Without Heater Kit, Min Circuit Amps 8.5 Without Heater Kit, Filter Size 16 x 20, Includes Evaporator Coil And R410A TXV Metering Device |
COMFORT-AIRE HAGV60-00-1A |
6ELE6 Grainger |
|
Single Piece Air Handler, 3-Position, Nominal Capacity 1.5 Tons, Rated CFM @ 0.5 (in WC) High 767, Voltage 230, Height 46 In., Width 17 1/2 In., Depth 21 1/2 In., Supply Opening Width 10 3/8 In., Supply Opening Depth 14 5/8 In., Return Air Opening Width 13 7/8 In., Return Air Opening Depth 18 7/8 In., Use with Heater Models S1-4HK, Liquid Line Size 3/8 ODS In., Suction Line Size 3/4 ODS In. |
DAYTON 6ELE6 |
6ELE7 Grainger |
|
Single Piece Air Handler, 3-Position, Nominal Capacity 2.0 Tons, Rated CFM @ 0.5 (in WC) High 691, Voltage 230, Height 46 In., Width 17 1/2 In., Depth 21 1/2 In., Supply Opening Width 10 3/8 In., Supply Opening Depth 14 5/8 In., Return Air Opening Width 13 7/8 In., Return Air Opening Depth 18 7/8 In., Use with Heater Models S1-4HK, Liquid Line Size 3/8 ODS In., Suction Line Size 3/4 ODS In. |
DAYTON 6ELE7 |
6ELE8 Grainger |
|
Single Piece Air Handler, 3-Position, Nominal Capacity 2.5 Tons, Rated CFM @ 0.5 (in WC) High 941, Voltage 230, Height 46 In., Width 17 1/2 In., Depth 21 1/2 In., Supply Opening Width 10 3/8 In., Supply Opening Depth 14 5/8 In., Return Air Opening Width 13 7/8 In., Return Air Opening Depth 18 7/8 In., Use with Heater Models S1-4HK, Liquid Line Size 3/8 ODS In., Suction Line Size 3/4 ODS In. |
DAYTON 6ELE8 |
6ELE9 Grainger |
|
Single Piece Air Handler, 3-Position, Nominal Capacity 3.0 Tons, Rated CFM @ 0.5 (in WC) High 1106, Voltage 230, Height 52 In., Width 21 In., Depth 21 1/2 In., Supply Opening Width 10 3/8 In., Supply Opening Depth 18 3/8 In., Return Air Opening Width 17 5/8 In., Return Air Opening Depth 18 7/8 In., Use with Heater Models S1-4HK, Liquid Line Size 3/8 ODS In., Suction Line Size 7/8 ODS In. |
DAYTON 6ELE9 |
6ELF1 Grainger |
|
Single Piece Air Handler, 3-Position, Nominal Capacity 4.0 Tons, Rated CFM @ 0.5 (in WC) High 1527, Voltage 230, Height 57 In., Width 24 1/2 In., Depth 21 1/2 In., Supply Opening Width 10 3/8 In., Supply Opening Depth 21 5/8 In., Return Air Opening Width 20 7/8 In., Return Air Opening Depth 18 7/8 In., Use with Heater Models S1-4HK, Liquid Line Size 3/8 ODS In., Suction Line Size 7/8 ODS In. |
DAYTON 6ELF1 |
6ELF2 Grainger |
|
Single Piece Air Handler, 3-Position, Nominal Capacity 5.0 Tons, Rated CFM @ 0.5 (in WC) High 1783, Voltage 230, Height 61 In., Width 24 1/2 In., Depth 21 1/2 In., Supply Opening Width 10 3/8 In., Supply Opening Depth 21 5/8 In., Return Air Opening Width 20 7/8 In., Return Air Opening Depth 18 7/8 In., Use with Heater Models S1-4HK, Liquid Line Size 3/8 ODS In., Suction Line Size 7/8 ODS In. |
DAYTON 6ELF2 |