Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
3PCK4 Grainger |
 |
Ultrasonic Flow Detector, Adjustable Small Diameter, Flow Velocity Range 0 to 32.8 FPS, Flow Velocity Range 0 to 10 MPS, Pipe Size 0.51 to 3.94 In, Pipe Size 13 to 100 mm, Fluid Temp Range -40 to 212 Deg F, Fluid Temp Range -40 to 100 Deg C, Accuracy 1.5 %, Enclosure Rating IP52, Ambient Temp Range 140 F, Electrical Connections Terminal Screws, For Use With 3PCJ7 & 3PCJ8, Includes (2) 5 M Cables, Plastic Belt and Silicone Grease Couplant |
DWYER INSTRUMENTS PSX2-B |
3PCK5 Grainger |
 |
Ultrasonic Flow Detector, Adjustable Large Diameter, Flow Velocity Range 0 to 32.8 FPS, Flow Velocity Range 0 to 10 MPS, Pipe Size 7.87 to 236.22 In, Pipe Size 20 to 6000 mm, Fluid Temp Range -40 to 176 Deg F, Fluid Temp Range -40 to 80 Deg C, Accuracy 1 %, Enclosure Rating IP67, Ambient Temp Range 140 F, Electrical Connections Terminal Screws, For Use With 3PCJ7 & 3PCJ8, Includes (2) 5 M Cables, (2) Stainless Steel Wires, (2) Springs and Silicone Grease Couplant |
DWYER INSTRUMENTS PSX2-D |
3PCK7 Grainger |
 |
Ultrasonic Flow Detector, Adjustable Small Sensor (2 MHz), Flow Velocity Range 0 to 32.8 FPS, Flow Velocity Range 0 to 10 MPS, Pipe Size 1.97 to 15.75 In, Pipe Size 50 to 400 mm, Fluid Temp Range -40 to 176 Deg F, Fluid Temp Range -40 to 80 Deg C, Accuracy 1 %, Enclosure Rating IP52, Ambient Temp Range 140 F, Electrical Connections Terminal Screws, For Use With 3PCJ7 & 3PCJ8, Includes (2) 5 M Cables, Plastic Belt and Silicone Grease Couplant |
DWYER INSTRUMENTS PSX2-A |
3PCL3 Grainger |
 |
Ultrasonic Flow Detector, Adjustable Small Diameter Sensor, Flow Velocity Range 0 to 105 FPS, Flow Velocity Range 0 to 32 MPS, Pipe Size 1.97 to 15.75 In, Pipe Size 50 to 400 mm, Fluid Temp Range -40 to 176 Deg F, Fluid Temp Range -40 to 80 Deg C, Accuracy Equal To or Less than 1.5 %, Enclosure Rating IP67, Ambient Temp Range 176 F, Electrical Connections Terminal Screws, For Use With 3PCK8, 3PCK9, 3PCL1 & 3PCL2, Includes Mounting Chain |
DWYER INSTRUMENTS SX1-A |
3PCL4 Grainger |
 |
Ultrasonic Flow Detector, Adjustable Medium Diameter Sensor, Flow Velocity Range 0 to 105 FPS, Flow Velocity Range 0 to 32 MPS, Pipe Size 1.97 to 47.24 In, Pipe Size 50 to 1200 mm, Fluid Temp Range -40 to 176 Deg F, Fluid Temp Range -40 to 80 Deg C, Accuracy Equal To or Less than 1.5 %, Enclosure Rating IP67, Ambient Temp Range 176 F, Electrical Connections Terminal Screws, For Use With 3PCK8, 3PCK9, 3PCL1 & 3PCL2, Includes Cable and Springs |
DWYER INSTRUMENTS SX1-B |
3PCL5 Grainger |
 |
Ultrasonic Flow Detector, Adjustable Large Diameter Sensor, Flow Velocity Range 0 to 105 FPS, Flow Velocity Range 0 to 32 MPS, Pipe Size 7.87 to 236.2 In, Pipe Size 200 to 6000 mm, Fluid Temp Range -40 to 176 Deg F, Fluid Temp Range -40 to 80 Deg C, Accuracy Equal To or Less than 1.5 %, Enclosure Rating IP67, Ambient Temp Range 176 F, Electrical Connections Terminal Screws, For Use With 3PCK8, 3PCK9, 3PCL1 & 3PCL2, Includes Cable and Springs |
DWYER INSTRUMENTS SX1-C |
3PCL8 Grainger |
 |
Ultrasonic Flow Detector, Portable Small Diameter Sensor, Accuracy Equal To or Less than 1.5 Percent, Material of Construction Plastic, Aluminum, Plastic Guide, Mounting Method Stainless Steel Band, Electrical Connections Terminal Screws, For Use With 3PCK8, 3PCK9, 3PCL1 & 3PCL2, Ambient Temp. Range 176 F, Enclosure Rating NEMA 3, IP52, Includes Stainless Steel Band , Manufacturers Warranty Length 1 Year |
DWYER INSTRUMENTS SX2-A |
3PCL9 Grainger |
 |
Ultrasonic Flow Detector, Fixed High Temperature Sensor, Flow Velocity Range 0 to 105 FPS, Flow Velocity Range 0 to 32 MPS, Pipe Size 1.97 to 15.75 In, Pipe Size 50 to 400 mm, Fluid Temp Range -40 to 392 Deg F, Fluid Temp Range -40 to 200 Deg C, Accuracy Equal To or Less than 1.5 %, Enclosure Rating NEMA 3, IP52, Ambient Temp Range 176 F, Electrical Connections Terminal Screws, For Use With 3PCK8, 3PCK9, 3PCL1 & 3PCL2, Includes Stainless Steel Band |
DWYER INSTRUMENTS SX2-B |
3PCR4 Grainger |
 |
Ultrasonic Flow Detector, Adjustable Small Standard Sensor, Flow Velocity Range 0 to 32.8 FPS, Flow Velocity Range 0 to 10 MPS, Pipe Size Plastic Pipe 0.98 to 3.94, Metal pipe 1.97 to 3.94 In, Pipe Size Plastic pipe 25 to 100, Metal pipe 50 to 100 mm, Fluid Temp Range -4 to 212 Deg F, Fluid Temp Range -20 to 80 Deg C, Accuracy 2 %, Enclosure Rating IP65, Ambient Temp Range -4 to 140 F, Electrical Connections Coaxial cable, For Use With 3PCN1 to 2PCR3 |
DWYER INSTRUMENTS SX3-A0 |
3PCR5 Grainger |
 |
Ultrasonic Flow Detector, Adjustable Small Sensor, Flow Velocity Range 0 to 32.8 FPS, Flow Velocity Range 0 to 10 MPS, Pipe Size 1.97 to 8.86 In, Pipe Size 50 to 225 mm, Fluid Temp Range -4 to 212 Deg F, Fluid Temp Range -20 to 80 Deg C, Accuracy 2 %, Enclosure Rating IP65, Ambient Temp Range -4 to 140 F, Electrical Connections Coaxial cable, For Use With 3PCN1 to 2PCR3 |
DWYER INSTRUMENTS SX3-B0 |