Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
3MNG4 Grainger |
|
Thermometer Calibrator, Temp. Range 40 Degrees F, 4.5 Degrees C, Temp. Accuracy +/-0.2 Degrees F, Temp. Stability +/-0.09 Degrees F, Stem Hole Dia. 0.25 In., 0.125 In., 0.187 In., 0.375 In., Well Depth 8 In. (204mm), Removable Inserts No, Power Required 90 to 130VAC, 50/60 Hz, 25W, Height 3-1/16 In., Width 6-5/8 In., Depth 10-7/8 In.Calibration Certificate NIST, Includes Certificate Of Calibration Traceable To NIST, Tip Sensitive Probe Adapter, Operating Instructions, and Two Cleaning Brushes |
TEL-TRU 3MNG4 |
3MNG6 Grainger |
|
Thermometer Calibrator, Temp. Range 160 Degrees F, 71 Degrees C, Temp. Accuracy +/-0.2 Degrees F, Temp. Stability +/-0.06 Degrees F, Stem Hole Dia. 0.15 In., Well Depth 8 In. (204mm), Removable Inserts No, Power Required 90 to 130VAC, 50/60 Hz, 45W, Height 3-1/16 In., Width 6-5/8 In., Depth 10-7/8 In.Calibration Certificate NIST, Includes Certificate Of Calibration Traceable To NIST, Dial Adjustment Tool, Operating Instructions, and Cleaning Brush |
GRAINGER APPROVED VENDOR 3MNG6 |
4LGZ9 Grainger |
|
Dry Well Calibrator, Temp. Range 95 Degrees to 707 Degrees F, 35 Degrees to 375 Degrees C, Temp. Accuracy +/-0.45 Degrees F at 122 Degrees F, +/-0.9 Degrees F at 707 Degrees F, +/- 0.25 Degrees C at 50 Degrees C; +/- 0.25 Degrees C at 100 Degrees C; +/- 0.5 Degrees C at 375 Degrees C, Temp. Stability +/- 0.07 Degrees C at 50 Degrees C; +/- 0.1 Degrees C at 100 Degrees C; +/- 0.3 Degrees C at 375 Degrees C, Stem Hole Dia. 0.0625 In., 0.125 In., 0.15625 In., 0.1875 In. and 0.25 In. Probes |
HART 9100S-A-156 |
4LHA1 Grainger |
|
Dry Well Calibrator, Temp. Range 95 Degrees to 707 Degrees F, 36 Degrees to 375 Degrees C, Temp. Accuracy +/-0.45 Degrees F at 122 Degrees F, +/-0.9 Degrees F at 707 Degrees F, +/- 0.25 Degrees C at 50 Degrees C; +/- 0.25 Degrees C at 100 Degrees C; +/- 0.5 Degrees C at 375 Degrees C, Temp. Stability +/- 0.07 Degrees C at 50 Degrees C; +/- 0.1 Degrees C at 100 Degrees C; +/- 0.3 Degrees C at 375 Degrees C, Stem Hole Dia. 0.125 In., 0.1875 In., 0.25 In. and 0.375 In. Probes |
HART 9100S-B-156 |
4LHA2 Grainger |
|
Dry Well Calibrator, Temp. Range 14 Degrees to 252 Degrees F, -10 Degrees to 122 Degrees C, Temp. Accuracy +/-0.45 Degrees F, +/-0.25 Degrees C, Temp. Stability +/- 0.05 Degrees C, Stem Hole Dia. 0.0625 In., 0.125 In., 0.1875 In., 0.25 In., 0.3125 In., 0.375 In., 0.4375 In. or 0.15625 In. Probes (Dependent on Inserts Used), Well Depth 4 In. (102mm), Removable Inserts Yes, Power Required 94 to 234VAC (+/-10 Percent), 50/60 Hz, Height 3.9 In., Width 5.5 In., Depth 6.9 In., Interface RS-232 |
HART 9102S-156 |
4LHA6 Grainger |
|
Dry Well Calibrator, Temp. Range Cold Block: 5 Degrees to 230 Degrees F, -15 Degrees to 110 Degrees C, Hot Block: 122 Degrees to 662 Degrees F, 50 Degrees to 350 Degrees C, Temp. Accuracy Cold Block: +/-0.36 Degrees F, +/-0.2 Degrees C, Hot Block: +/-1.08 Degrees F, +/-0.6 Degrees C, Temp. Stability +/- 0.05 Degrees C, Stem Hole Dia. 0.0625 In., 0.125 In., 0.1875 In., 0.25 In., 0.3125 In., 0.375 In., 0.4375 In. or 0.15625 In. Probes (Dependent on Inserts Used), Well Depth 4 In. (102mm) |
HART 9009-B-156 |
4LNK5 Grainger |
|
Thermometer Calibrator, Temp. Range 40 Degrees F, 4.5 Degrees C and 160 Degrees F, 71 Degrees C, Temp. Accuracy +/-0.2 Degrees F, Temp. Stability +/-0.07 Degrees F, Stem Hole Dia. 0.25 In., 0.125 In., 0.187 In., 0.375 In., Well Depth 8 In. (204mm), Removable Inserts No, Power Required 90 to 130VAC, 50/60 Hz, 25W, Height 3-1/16 In., Width 6-5/8 In., Depth 10-7/8 In.Calibration Certificate NIST |
GRAINGER APPROVED VENDOR 4LNK5 |