Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
3C590 Grainger |
|
Noninsulated Flexible DuctInside Dia. 3 In., Wall Thickness 1/8 In., Vapor Transmission 0.05, Material Aluminum, Length 15 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 500?F, Compressed Size 30 In.For Use With Heating and Cooling SystemsIncludes (2) Stainless Steel Screw Clamps |
WESTAFLEX 2501 |
3C591 Grainger |
|
Noninsulated Flexible DuctInside Dia. 4 In., Wall Thickness 1/8 In., Vapor Transmission 0.05, Material Aluminum, Length 15 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 500?F, Compressed Size 30 In.For Use With Heating and Cooling SystemsIncludes (2) Stainless Steel Screw Clamps |
WESTAFLEX 2505 |
3F322 Grainger |
|
Insulated Flexible Duct, Insulation Value R 4.2, UPC Number 30, Inside Dia. 4 In., Wall Thickness 1-1/4 In., Vapor Transmission 0.05, Material Polyester, Length 25 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 180 Degrees FLow Temp. Deg. -20 Degrees FFor Use With Heating and Cooling Systems, Features Air Tight Inner Core, Encapsulated Wire Helix, Smooth Inner Core, Thick Blanket of Fiberglass Insulation, Tough Reinforced Metallized Polyester Jacket, Light Weight Compact Carton |
ATCO 030254 |
3F323 Grainger |
|
Insulated Flexible Duct, Insulation Value R 4.2, UPC Number 30, Inside Dia. 6 In., Wall Thickness 1-1/4 In., Vapor Transmission 0.05, Material Polyester, Length 25 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 180 Degrees FLow Temp. Deg. -20 Degrees FFor Use With Heating and Cooling Systems, Features Air Tight Inner Core, Encapsulated Wire Helix, Smooth Inner Core, Thick Blanket of Fiberglass Insulation, Tough Reinforced Metallized Polyester Jacket, Light Weight Compact Carton |
ATCO 030256 |
3F324 Grainger |
|
Insulated Flexible Duct, Insulation Value R 4.2, UPC Number 30, Inside Dia. 8 In., Wall Thickness 1-1/4 In., Vapor Transmission 0.05, Material Polyester, Length 25 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 180 Degrees FLow Temp. Deg. -20 Degrees FFor Use With Heating and Cooling Systems, Features Air Tight Inner Core, Encapsulated Wire Helix, Smooth Inner Core, Thick Blanket of Fiberglass Insulation, Tough Reinforced Metallized Polyester Jacket, Light Weight Compact Carton |
ATCO 030258 |
3F325 Grainger |
|
Insulated Flexible Duct, Insulation Value R 4.2, UPC Number 30, Inside Dia. 10 In., Wall Thickness 1-1/4 In., Vapor Transmission 0.05, Material Polyester, Length 25 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 180 Degrees FLow Temp. Deg. -20 Degrees FFor Use With Heating and Cooling Systems, Features Air Tight Inner Core, Encapsulated Wire Helix, Smooth Inner Core, Thick Blanket of Fiberglass Insulation, Tough Reinforced Metallized Polyester Jacket, Light Weight Compact Carton |
ATCO 0302510 |
3F326 Grainger |
|
Insulated Flexible Duct, Insulation Value R 4.2, UPC Number 30, Inside Dia. 12 In., Wall Thickness 1-1/4 In., Vapor Transmission 0.05, Material Polyester, Length 25 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 180 Degrees FLow Temp. Deg. -20 Degrees FFor Use With Heating and Cooling Systems, Features Air Tight Inner Core, Encapsulated Wire Helix, Smooth Inner Core, Thick Blanket of Fiberglass Insulation, Tough Reinforced Metallized Polyester Jacket, Light Weight Compact Carton |
ATCO 0302512 |
3F327 Grainger |
|
Insulated Flexible Duct, Insulation Value R 4.2, UPC Number 70, Inside Dia. 4 In., Wall Thickness 1-1/4 In., Vapor Transmission 0.6, Material Polyester, Length 25 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 180 Degrees FLow Temp. Deg. -20 Degrees FFor Use With Heating and Cooling Systems, Features Air Tight Inner Core, Encapsulated Wire Helix, Smooth Inner Core, Thick Blanket of Fiberglass Insulation, Tough Reinforced Gray Polyester Jacket, Light Weight Compact Carton |
ATCO 070254 |
3F328 Grainger |
|
Insulated Flexible Duct, Insulation Value R 4.2, UPC Number 70, Inside Dia. 6 In., Wall Thickness 1-1/4 In., Vapor Transmission 0.6, Material Polyester, Length 25 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 180 Degrees FLow Temp. Deg. -20 Degrees FFor Use With Heating and Cooling Systems, Features Air Tight Inner Core, Encapsulated Wire Helix, Smooth Inner Core, Thick Blanket of Fiberglass Insulation, Tough Reinforced Gray Polyester Jacket, Light Weight Compact Carton |
ATCO 070256 |
3F329 Grainger |
|
Insulated Flexible Duct, Insulation Value R 4.2, UPC Number 70, Inside Dia. 8 In., Wall Thickness 1-1/4 In., Vapor Transmission 0.6, Material Polyester, Length 25 ft., Max. Air Flow 5000 fpm, Max. Pressure 6 In.WC, Max. Temp. 180 Degrees FLow Temp. Deg. -20 Degrees FFor Use With Heating and Cooling Systems, Features Air Tight Inner Core, Encapsulated Wire Helix, Smooth Inner Core, Thick Blanket of Fiberglass Insulation, Tough Reinforced Gray Polyester Jacket, Light Weight Compact Carton |
ATCO 070258 |