Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
2TE33 Grainger |
 |
Make-Up Air Heater, Direct Fired, Natural Gas, BtuH Input 200, 000, CFM @ 0.250-In SP 2198, @ 0.375-In SP 1995, Sones @ 0.250-In SP @ 5 Ft 16.5, Burner Control Circuit 24 Volt, Turn Down Ratio 25:1 With Electronic Modulating, Motor HP 1, Volts 115/208-230, 60 Hz, 1 Phase, Full Load Amps 12.8/6.4-6.4, Housing Height 29 3/4 In, Housing Width 33 1/3 In, Housing Length 107 1/8 In, Discharge Length 12 1/4 In, Discharge Width 10 3/4 In, Requires Roof Curb For New Installation |
DAYTON 2TE33 |
2TE34 Grainger |
 |
Make-Up Air Heater, Direct Fired, Natural Gas, BtuH Input 300, 000, CFM @ 0.250-In SP 3026, @ 0.375-In SP 2863, Sones @ 0.250-In SP @ 5 Ft 19.1, Burner Control Circuit 24 Volt, Turn Down Ratio 25:1 With Electronic Modulating, Motor HP 1 1/2, Volts 115/208-230, 60 Hz, 1 Phase, Full Load Amps 13.2/7.2-6.6, Housing Height 29 3/4 In, Housing Width 33 1/3 In, Housing Length 107 1/8 In, Discharge Length 13 5/8 In, Discharge Width 11 7/8 In, Requires Roof Curb For New Installation |
DAYTON 2TE34 |
2TE35 Grainger |
 |
Make-Up Air Heater, Direct Fired, Natural Gas, BtuH Input 400, 000, CFM @ 0.250-In SP 4500, @ 0.375-In SP 4295, Sones @ 0.250-In SP @ 5 Ft 20, Burner Control Circuit 24 Volt, Turn Down Ratio 25:1 With Electronic Modulating, Motor HP 3, Volts 208-230/460, 60 Hz, 3 Phase, Full Load Amps 8.7-8.0/4.0, Housing Height 29 3/4 In, Housing Width 31 1/2 In, Housing Length 107 1/8 In, Discharge Length 16 In, Discharge Width 13 7/8 In, Requires Roof Curb For New Installation |
DAYTON 2TE35 |
3CCR7 Grainger |
 |
Make-Up Air Heater, Direct Fired, Natural Gas, BtuH Input 400, 000, CFM @ 0.250-In SP 4500, @ 0.375-In SP 4295, Sones @ 0.250-In SP @ 5 Ft 20, Burner Control Circuit 24 Volt, Turn Down Ratio 25:1 With Electronic Modulating, Motor HP 3, Volts 115/208-230, 60 Hz, 1 Phase, Full Load Amps 33.0/16.5, Housing Height 29 3/4 In, Housing Width 31 1/2 In, Housing Length 107 1/8 In, Discharge Length 18 In, Discharge Width 16 In, Requires Roof Curb For New Installation |
DAYTON 3CCR7 |
3CCR8 Grainger |
 |
Make-Up Air Heater, Direct Fired, Natural Gas, BtuH Input 800, 000, CFM @ 0.250-In SP 6780, @ 0.375-In SP 6470, Sones @ 0.250-In SP @ 5 Ft 33.7, Burner Control Circuit 24 Volt, Turn Down Ratio 25:1 With Electronic Modulating, Motor HP 5, Volts 208-230/460, 60 Hz, 3 Phase, Full Load Amps 14.6-13.2/6.6, Housing Height 39 In, Housing Width 49 1/2 In, Housing Length 136 1/4 In, Discharge Length 22 In, Discharge Width 18 In, Requires Roof Curb For New Installation |
DAYTON 3CCR8 |
3CCR9 Grainger |
 |
Make-Up Air Heater, Direct Fired, Natural Gas, BtuH Input 800, 000, CFM @ 0.250-In SP 8790, @ 0.375-In SP 8400, Sones @ 0.250-In SP @ 5 Ft 26.8, Burner Control Circuit 24 Volt, Turn Down Ratio 25:1 With Electronic Modulating, Motor HP 5, Volts 208-230/460, 60 Hz, 3 Phase, Full Load Amps 14.6-13.2/6.6, Housing Height 39 In, Housing Width 49 1/2 In, Housing Length 136 1/4 In, Discharge Length 24 In, Discharge Width 22 In, Requires Roof Curb For New Installation |
DAYTON 3CCR9 |