Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
1VL50 Grainger |
|
Fixed Gas Detector, Gas Type CO, Number of Channels 1, Sensor Range 0 to 999 ppm, Resolution 1 ppm, Alarm Type Two Color High Intensity Visual, 85dB @ 3 ft. Built-in Audible, Display LED, Status Indicator YesNEMA Rating 4For Use With Any 4-20 mA Transmitter, Power Required 12 to 24VDC, Height 1-5/8 In., Width 7-1/4 In., Depth 5-5/8 In., Color Gray, Operating Temp. Range -4 to 104 Degrees F, Standards CSA Approved for Non-hazardous Locations, Includes Electrochemical Sensor |
INDUSTRIAL SCIENTIFIC Air-Aware-11300 |
1VL51 Grainger |
|
Fixed Gas Detector, Gas Type O2, Number of Channels 1, Sensor Range 0 to 30 Percent by Volume, Resolution 0.1 Percent, Alarm Type Two Color High Intensity Visual, 85dB @ 3 ft. Built-in Audible, Display LED, Status Indicator YesNEMA Rating 4For Use With Any 4-20 mA Transmitter, Power Required 12 to 24VDC, Height 1-5/8 In., Width 7-1/4 In., Depth 5-5/8 In., Color Gray, Operating Temp. Range -4 to 104 Degrees F, Standards CSA Approved for Non-hazardous Locations, Includes Electrochemical Sensor |
INDUSTRIAL SCIENTIFIC Air-Aware-A1300 |
1VL52 Grainger |
|
Fixed Gas Detector, Gas Type O2, Number of Channels 1, Sensor Range 0 to 30 Percent by Volume, Resolution 0.1 Percent, Alarm Type Two Color High Intensity Visual, 85dB @ 3 ft. Built-in Audible, Display LED, Status Indicator YesNEMA Rating 4Power Required 120VAC or 12 to 24VDC, Height 1-5/8 In., Width 7-1/4 In., Depth 5-5/8 In., Color Gray, Operating Temp. Range -4 to 104 Degrees F, Standards CSA Approved for Non-hazardous Locations, Includes Electrochemical Sensor, AC Adapter (Installed) |
INDUSTRIAL SCIENTIFIC Air-Aware-A1010 |
25K785 Grainger |
|
Fixed Gas Detector, Gas Type C3H8, CH4, Number of Channels 1, Sensor Range 0 to 99 Percent by Volume, Resolution 1 Percent, Alarm Type Audible/Visual, Display No, Status Indicator LED Lights, Features End of Life Signal, NEMA Rating Type 1, IP Rating IP32Power Required 120VAC, Height 3 In., Width 5-1/2 In., Depth 1-3/8 In., Color Gray, Operating Temp. Range -31 to 150 Degrees F, Standards UL Listed to UL 1484 and ULC, CGA Approved, Includes Locking Bracket |
SAFE-T-ALERT 40-411-P |
39H974 Grainger |
|
Fixed Gas Detector, Gas Type C3H8, CH4, Number of Channels 1, Sensor Range 0-99 Percent by Volume, Resolution 0.01, Alarm Type Audible and Visual, Display No, Status Indicator LED Lights, Features End of Life Signal, NEMA Rating Type 1, IP Rating IP32Power Required 120VAC, Height 2-1/4 In., Width 3-1/4 In., Depth 1-1/2 In., Color White, Operating Temp. Range -31 to 150 Degrees F, Standards UL Listed to UL 1484 and ULC, CGA Approved, Includes Locking Bracket |
SAFE-T-ALERT 20-411-P |
3UCH4 Grainger |
|
Carbon Monoxide Alarm, Gas Type COSensor Range 0 to 999 ppm, Resolution 1 ppm, Alarm Type Audible and Visual, Display LEDNEMA Rating 4Power Required 12-24 VDC (110 VAC Adapter Option), Height 7.2 In., Width 5.6 In., Depth 1.6 In., Color White, Operating Temp. Range -4 to 122 Degrees F, Standards CSA, Includes Electrochemical Sensor, Two Ultra-bright LEDs - Yellow for Low-Alarm and Red for High-Alarm, AC Power Adapter, Vanity Plate |
INDUSTRIAL SCIENTIFIC 3UCH4 |
5HP91 Grainger |
|
Fixed Gas Detector, Gas Type CO, Number of Channels 1, Sensor Range 0 to 1999 ppm, Resolution 1 ppm, Alarm Type Red Strobe, Display 4 Digit LED, Status Indicator No, Features 16 ga. Steel Housing, Internal Lamp When Cover is OpenedPower Required 105 to 130VAC, Height 10 In., Width 8 In., Depth 4 In., Color Gray, Operating Temp. Range -4 to 122 Degrees F, Standards CSA, Indoor Use, Includes 16 Gauge Steel, Red Alarm Strobe |
INDUSTRIAL SCIENTIFIC RS5100-2313 |
5HR72 Grainger |
|
Fixed Gas Detector, Gas Type CO, Number of Channels 1, Sensor Range 0 to 999 ppm, Resolution 1 ppm, Alarm Type Two Color Visual, Display 3-1/2 Digit High Resolution LED, Status Indicator YesNEMA Rating 4Power Required 120VAC or 12 to 24VDC, Height 1-5/8 In., Width 7-1/4 In., Depth 5-5/8 In., Color Gray, Operating Temp. Range -4 to 104 Degrees F, Standards CSA Approved for Non-hazardous Locations, Includes Electrochemical Sensor, AC Adapter (Installed) |
INDUSTRIAL SCIENTIFIC Air-Aware-11010 |
8CKE7 Grainger |
|
Fixed Gas Detector, Gas Type C3H8, CH4, Number of Channels 1Alarm Type 85dB @ 3 ft. Built-in AudibleStatus Indicator No, Features Test/Reset ButtonPower Required 120 VAC, Height 3 In., Width 5-1/2 In., Depth 1-3/8 In., Color Gray, Operating Temp. Range -31 to 150 Degrees F, Standards UL Listed to UL 1484 and ULC, CGA Approved |
SAFE-T-ALERT 40-411B |
8CKW7 Grainger |
|
Fixed Gas Detector, Gas Type NH3, Number of Channels 1, Sensor Range 0.2 to 50 ppm, Resolution 0.1 ppm, Alarm Type Two Color High Intensity Visual, 85dB @ 3 ft. Built-in Audible, Display LED, Status Indicator Yes, Features On-Board Relays, NEMA Rating 4Power Required 120VAC or 12 to 24VDC, Height 1-5/8 In., Width 5-5/8 In., Depth 7-1/4 In., Color Gray, Operating Temp. Range -4 to 122 Degrees F, Standards CSA Approved for Non-hazardous Locations, Includes AC Adapter (Installed) |
INDUSTRIAL SCIENTIFIC 68100056-31110 |