Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
1TTZ9 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1/2 HP, 3450 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 2.1-2.4/1.2, Phase 3, 60 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 12-25/64 In., Lead Length 6 In. |
MARATHON MOTORS 56T34G15545 |
1TUA1 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1/2 HP, 1140 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 2.4-2.7/1.4, Phase 3, 60 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.15, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 13-61/64 In., Lead Length 6 In. |
MARATHON MOTORS 56T11G15512 |
1TUA2 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 3/4 HP, 3450 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 3.0-3.2/1.6, Phase 3, 60 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.15, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 12-31/32 In., Lead Length 6 In. |
MARATHON MOTORS 56T34G15541 |
1TUA3 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 3/4 HP, 1140 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 3.2-3.2/1.6, Phase 3, 60 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.15, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 13-61/64 In., Lead Length 6 In. |
MARATHON MOTORS 56T11G15513 |
1TUA4 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1 HP, 3450 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 3.9-3.6/1.8, Phase 3, 60 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.15, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 12-31/32 In., Lead Length 6 In. |
MARATHON MOTORS 56T34G15530 |
1TUA5 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1 HP, 1140 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 3.6-3.4/1.7, Phase 3, 60 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.15, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 15-29/64 In., Lead Length 6 In. |
MARATHON MOTORS 56T11G15514 |
1TUA8 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 2 HP, 3450 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 6.0-6.0/3.0, Phase 3, 60 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.15, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 14-15/32 In., Lead Length 6 In. |
MARATHON MOTORS 56T34G15532 |
1TUC2 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1/2 HP, 3450 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 2.1-2.4/1.2, Phase 3, 60 Hz, Face/Base Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 15-1/4 In., Lead Length 6 In. |
MARATHON MOTORS 56T34G15544 |
1TUC3 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 3/4 HP, 3450 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 3.0-3.2/1.6, Phase 3, 60 Hz, Face/Base Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.15, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 12-31/32 In., Lead Length 6 In. |
MARATHON MOTORS 56T34G15534 |
1TUC4 Grainger |
 |
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 3/4 HP, 1725 Nameplate RPM, 145TC NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 2.9-3.0/1.5, Phase 3, 60/50 Hz, Face/Base Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection T Stat, Service Factor 1.15, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 7/8 In., Shaft Length 2-1/8 In., Overall Length 14 In. |
MARATHON MOTORS 145TTGR14041 |