Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
13X132 Grainger |
 |
Earth Ground Tester, Earth Ground Resistance Range 0.002/0.02/0.2/2k Ohms, Resolution 0.001 to 1k Ohms, Operating Frequency 820 Hz, Accuracy +/-2 Percent of Reading +/-3 Digits, Measuring Current 2mAEarth Volts 0 to 300VACDisplay Dual Line LCD, Counts 20, 000, Power Source (8) 1.5V AA Batteries, Standards EN 61010-1, EN 61326-1, EN 61557-1, EN 61557-5, Pollution Degree 2, Safety Rating CAT IV 300VEarth Measurement Poles (4) Auxillary Earth Bars |
EXTECH GRT300 |
1FBK4 Grainger |
 |
Earth Ground Tester, Earth Ground Resistance Range 0.001 to 19.99k Ohms, Resolution 0.001 to 10 Ohms, Operating Frequency 128 Hz, Accuracy +/-2 Percent of Reading +/-3 Digits or +/-7 Percent of Reading +/-3 Digits, Measuring Current Greater Than 50mA, Measuring Voltage Less Than =48V, Earth Volts 250VAC, Soil Resistivity Yes, Display LCD, Counts 1999, Power Source (6) AA Batteries, Standards CE, CSAEarth Measurement Clamps (1) Selective, (2) Stakeless, Earth Measurement Poles 34 |
FLUKE FLUKE-1623 |
1FBK5 Grainger |
 |
Earth Ground Tester Kit, Earth Ground Resistance Range 0.001 to 19.99k Ohms, Resolution 0.001 to 10 Ohms, Operating Frequency 128 Hz, Accuracy +/-2 Percent of Reading +/-3 Digits or +/-7 Percent of Reading +/-3 Digits, Measuring Current Greater Than 50mA, Measuring Voltage Less Than =48V, Earth Volts 48VAC, Soil Resistivity Yes, Display LCD, Counts 1999, Power Source (6) AA Batteries, Standards CE, CSAEarth Measurement Clamps (1) Selective, (2) Stakeless, Earth Measurement Poles 34 |
FLUKE FLUKE-1623 KIT |
1FBK6 Grainger |
 |
Earth Ground Tester, Earth Ground Resistance Range 0.001 to 299.9k Ohms, Resolution 0.001 to 100 Ohms, Operating Frequency 94/105/111/128 Hz, Accuracy +/-2 Percent of Reading +/-2 Digits or +/-7 Percent of Reading +/-2 Digits, Measuring Current 250mA, Measuring Voltage 20/48V, Earth Volts 250VAC, Soil Resistivity Yes, Display LCD, Counts 2999, Power Source (6) AA Batteries, Standards CE, CSAEarth Measurement Clamps (1) Selective, (2) Stakeless, Earth Measurement Poles 2, 3, 4 (AC), 2 and 4 (DC) |
FLUKE FLUKE-1625 |
1FBK7 Grainger |
 |
Earth Ground Tester Kit, Earth Ground Resistance Range 0.001 to 299.9k Ohms, Resolution 0.001 to 100 Ohms, Operating Frequency 94/105/111/128 Hz, Accuracy +/-2 Percent of Reading +/-2 Digits or +/-7 Percent of Reading +/-2 Digits, Measuring Current 250mA, Measuring Voltage 20/48V, Earth Volts 48VAC, Soil Resistivity Yes, Display LCD, Counts 2999, Power Source (6) AA Batteries, Standards CE, CSAEarth Measurement Clamps (1) Selective, (2) Stakeless, Earth Measurement Poles 2, 3, 4 (AC), 2 and 4 (D |
FLUKE FLUKE-1625 KIT |
24K395 Grainger |
 |
Earth Ground Tester, Earth Ground Resistance Range 0.00001 to 0.019/0.1999/1.999/19.99/49.9k Ohms, Resolution 0.01 to 1 Ohms, Operating Frequency 77.5 Hz, Accuracy +/-2 Percent of Reading +/-2 LSD, Measuring Current 12mA, Measuring Voltage Less Than =25V, Earth Volts 460VAC, Soil Resistivity Yes, Display LCD, Counts 2000Standards IEC, EN 61010-1, EN 1557-1, EN 1557-5, EN 61557-1/-5, EN 61326, Safety Rating CAT III 240V, Interface PC, Earth Measurement Clamps No, Earth Measurement Poles 4 |
AMPROBE GP-2A |
2FTY7 Grainger |
 |
Earth Ground Tester, Earth Ground Resistance Range 0.15 to 2k Ohms, Resolution 0.01 to 1 Ohms, Operating Frequency 128 Hz, Accuracy +/-6 Percent of Reading +/-5 Digits or +/-18 Percent of Reading +/-5 Digits, Measuring Current Greater Than 50mA, Measuring Voltage Less Than =48V, Earth Volts 250VAC, Soil Resistivity No, Display LCD, Counts 1999, Power Source (1) 9V Battery, Standards IEC, EN 61010-1, Pollution Degree 2, Safety Rating CAT II 600VEarth Measurement Poles 23 |
FLUKE FLUKE-1621 |
2MY25 Grainger |
 |
Earth Ground Tester, Earth Ground Resistance Range 0.00001 to 2k OhmsOperating Frequency 128 Hz, Accuracy +/-2 Percent of Reading +/-3 Digits, Measuring Current 4.5mAEarth Volts 100VAC, Soil Resistivity Yes, Display Digital LCD, Counts 1999, Power Source (8) AA Batteries, Standards EN 61010-1, EN 61326-1, EN 61557-1, EN 61557-5, Safety Rating CAT IV 100VIncludes Carrying Case, Full Stake and Wire Test Kit, Batteries and Instructions, Manufacturers Warranty Length 3 yr. |
MEGGER DET3TC |
2MY35 Grainger |
 |
Earth Ground Tester, Earth Ground Resistance Range 0.01 to 99k OhmsOperating Frequency 40 to 513 Hz, Accuracy +/-2 Percent of Reading +/-1 Count, Measuring Current 250mAEarth Volts 16 to 32VAC, Soil Resistivity Yes, Display Digital LCD, Counts 1000, Power Source 9.6V Recharable Battery Pack, Standards EN 61010-1, Pollution Degree 2, Safety Rating CAT IV 50V, Interface USBIncludes Software, Battery Charger, AC Power Cord, NiMH Batteries, Interface Cable and Instructions |
AEMC 6470B |
2T597 Grainger |
 |
Earth Ground Tester, Earth Ground Resistance Range 0.0005 to 1k Ohms, Resolution 0.01 to 1 Ohms, Operating Frequency 128 Hz, Accuracy +/-5 Percent of Reading, Measuring Current 10mADisplay AnalogPower Source (8) AA Batteries, Standards CE, EN 61010-1, EN 50081-1, EN 50082-1, Pollution Degree 2, Safety Rating CAT III 24VIncludes (8) 1.5V AA Batteries |
AEMC 3620 |