12N826
Grainger
Подробнее... Control Measurement Relay, Voltage Sensing, Contact Form DPDT, 12 Pins, Base Type DIN Mount, Number of Contacts 2, Contact Amp Rating (Resistive) 1A @ 24 VDC, 3A @ 250 VAC, 5 A @ 24 VAC, Input Voltage 220 to 480 VAC, 3 Phase, Power Rating (VA) 1250, Trip Delay (Sec.) 0.1 to 10.0 (0 + 10 Percent), Pick Up Range 194 to 528 Vac, Drop-Out Range 2 to 20 Percent, Voltage Unbalance (Percent) 2 SCHNEIDER ELECTRIC
RM35TF30
12N827
Grainger
Подробнее... Control Measurement Relay, Voltage Sensing, Contact Form SPDT, 6 Pins, Base Type DIN Mount, Number of Contacts 1, Contact Amp Rating (Resistive) 1A @ 24 VDC, 3A @ 250 VAC, 5 A @ 24 VAC, Input Voltage 220 to 480 VAC, 3 Phase, Power Rating (VA) 1250, Trip Delay (Sec.) 0.1 to 10.0 (0 + 10 Percent), Pick Up Range 183 to 528 Vac, Drop-Out Range 2 to 20 Percent, Voltage Unbalance (Percent) Less Than 1 SCHNEIDER ELECTRIC
RM17TA00
12N828
Grainger
Подробнее... Control Measurement Relay, Voltage Sensing, w/Overvoltage or Undervoltage, Contact Form SPDT, 6 Pins, Base Type DIN Mount, Number of Contacts 1, Contact Amp Rating (Resistive) 1A @ 24 VDC, 3A @ 250 VAC, 5 A @ 24 VAC, Input Voltage 220 to 480 VAC, 3 Phase, Power Rating (VA) 1250, Trip Delay (Sec.) 0.1 to 10.0 (0 + 10 Percent), Pick Up Range 183 to 528 Vac, Drop-Out Range 2 to 20 Percent, Voltage Unbalance (Percent) Less Than 1 SCHNEIDER ELECTRIC
RM17TE00
1EJF1
Grainger
Подробнее... Relay, Voltage Sensing, Contact Form SPDT, Base Type DIN-Mount, Number of Contacts 1, Contact Amp Rating 15 R, Input Voltage 120VAC, Power Rating 1.2 VA, Trip Delay 0.1s-10s Sec., Pick Up Range 80-150VAC, Drop-Out Range 30-99, Voltage Unbalance 99 % DAYTON
1EJF1
1EJF2
Grainger
Подробнее... Relay, Voltage Sensing, Contact Form SPDT, Base Type DIN-Mount, Number of Contacts 1, Contact Amp Rating 15 R, Input Voltage 240VAC, Power Rating 1.2 VA, Trip Delay 0.1s-10s Sec., Pick Up Range 160-276VAC, Drop-Out Range 30-99, Voltage Unbalance 99 % DAYTON
1EJF2
5JJ49
Grainger
Подробнее... 3 Phase Line Monitor, Contact Form SPDT, Input Line Voltage 200 to 480 VAC, Trip Delay Time Range 0.25 to 30 Seconds, Automatic Voltage Range Selection, 2 to 10% Unbalanced Voltage SSAC
PLMU11
5WMJ3
Grainger
Подробнее... 3-Phase Line Monitor, Voltage Sensing, Contact Form SPDT, Pins 8, Base Type Octal, Number of Contacts 1, Contact Amp Rating (Resistive) 10, Input Voltage 208-480VAC, Phase Wye or Delta 3-wire, Power Rating (VA) 3, Trip Delay (Sec.) Power Up 1-300 Sec, Phase Loss & Reversal 100ms, Phase Unbalance 2 Sec, Undervoltage 0.1-20 Sec, Pick Up Range -, Drop-Out Range 80-95 Percent of Nominal Voltage, Voltage Unbalance ( Percent) 2 to 10 MACROMATIC
PMPU
5WMJ4
Grainger
Подробнее... 3-Phase Line Monitor, Voltage Sensing, Contact Form SPDT, Pins 8, Base Type Octal, Socket 5X852, Number of Contacts 1, Contact Amp Rating 10 R, Input Voltage 208VAC, Phase Wye or Delta 3-wire, Power Rating 3 VA, Drop-Out Range 75-95% of Nominal Voltage MACROMATIC
PAP208
5WMJ5
Grainger
Подробнее... 3-Phase Line Monitor, Voltage Sensing, Contact Form SPDT, Pins 8, Base Type Octal, Socket 5X852, Number of Contacts 1, Contact Amp Rating 10 R, Input Voltage 240VAC, Phase Wye or Delta 3-wire, Power Rating 3 VA, Drop-Out Range 75-95% of Nominal Voltage MACROMATIC
PAP240
5WMJ6
Grainger
Подробнее... 3-Phase Line Monitor, Voltage Sensing, Contact Form SPDT, Pins 8, Base Type Octal, Number of Contacts 1, Contact Amp Rating 10 R, Input Voltage 480VAC, Phase Wye or Delta 3-wire, Power Rating 3 VA, Drop-Out Range 75-95% of Nominal Voltage MACROMATIC
PAP480