Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
13A868 Grainger |
|
SoftwareHeight 1 In., Width 7-1/2 In., Depth 1 In. |
COOPER ATKINS 10400 |
13A869 Grainger |
|
Base Station Buffer, 900 MHz RF Communication Method, Temp. Range (F) 32 Degrees to 140 Degrees , Temp. Range (C) 0 Degrees to 60 Degrees , Power Source 11-14VDC, 60 Hz, 80mA, External Transformer, Battery Life 2-5 yr., Height 9 In., Width 4 In., Depth 6 In., Wireless Range 2500 ft. (762m), Manufacturers Warranty Length 1 yr. |
COOPER ATKINS 10000-5-P-US |
13A870 Grainger |
|
Repeater, 900 MHz RF Communication Method, Temp. Range (F) 32 Degrees to 140 Degrees , Temp. Range (C) 0 Degrees to 60 Degrees Power Source 120VAC, Battery Life 2-5 yr.Height 4 In., Width 7 In., Depth 4 In., Wireless Range 2500 ft. (762m)Manufacturers Warranty Length 1 yr. |
COOPER ATKINS 10050-US |
13A871 Grainger |
|
Steam Trap Transmitter, 900 MHz RF Communication Method, Temp. Range (F) -40 Degrees to 392 Degrees , Temp. Range (C) -40 Degrees to 200 Degrees , Accuracy +/-5 Degrees F / +/-2.8 Degrees C, Power Source Battery, (2) 2/3A 3V Lithium, Battery Life 2-5 yr., Features Dual Probe, Height 4 In., Width 10 In., Depth 4 In., Wireless Range 2500 ft. (762m), Calibration Certificate NIST, Manufacturers Warranty Length 1 yr. |
COOPER ATKINS 10098 |
13A872 Grainger |
|
Temperature/Humidity Transmitter, 900 MHz RF Communication Method, Temp. Range (F) -40 Degrees to 140 Degrees , Temp. Range (C) -40 Degrees to 60 Degrees , Relative Humidity Range 0 to 95 Percent, Accuracy +/-0.5 Degrees F (+/-0.3 Degrees C) at 77 Degrees F (25 Degrees C), Power Source 2/3 A Size LiMn02, Battery Life 2-5 yr., Features Internal Sensor, Height 3.5 In., Width 1.5 In., Depth 1 In., Wireless Range 2500 ft. (762m), Manufacturers Warranty Length 1 yr. |
COOPER ATKINS 10071 |
13A873 Grainger |
|
Contact Transmitter, 900 MHz RF Communication Method, Temp. Range (F) -4 Degrees to 140 Degrees , Temp. Range (C) -20 Degrees to 60 Degrees , Power Source 2/3 A Size LiMn02, Battery Life 2-5 yr., Features Door Open/Close, Height 3.5 In., Width 1.5 In., Depth 1 In., Wireless Range 2500 ft. (762m), Manufacturers Warranty Length 1 yr. |
COOPER ATKINS 10100-DT |
13A874 Grainger |
|
Air Probe, -25 to 180 Degrees Temp. Range (F), -32 to 82 Degrees Temp. Range (C), Features .5 In. Probe, Height 1 In., Width 3 In., Depth 1 In. |
COOPER ATKINS 2033 |
13A875 Grainger |
|
Glycol Probe, -25 to 180 Degrees Temp. Range (F), -32 to 82 Degrees Temp. Range (C), Features 6 In. Probe, Height 1 In., Width 6 In., Depth 1 In. |
COOPER ATKINS 10112 |
13A876 Grainger |
|
Solid Probe, -25 to 180 Degrees Temp. Range (F), -32 to 82 Degrees Temp. Range (C), Features 1.5 In. Probe Dia., Height 4 In., Width 5 In., Depth 1 In. |
COOPER ATKINS 10113 |
13A877 Grainger |
|
Temperature Transmitter, 900 MHz RF Communication Method, Temp. Range (F) -22 Degrees to 212 Degrees , Temp. Range (C) -30 Degrees to 100 Degrees , Accuracy 0.8F (0.5C) Internal, +/-1F external, Power Source 2/3 A Size LiMn02, Battery Life 2-5 yr., Features Internal/External Sensor, Height 1 In., Width 4 In., Depth 2.5 In., Wireless Range 2500 ft. (762m), Calibration Certificate NIST, Includes (1) 6 foot air probe, Manufacturers Warranty Length 1 yr. |
COOPER ATKINS 10080-DTG |