Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
12N578 Grainger |
|
A/C Compressor, BtuH 90, 500, Voltage 208/230, 3 Phase, Line Connection Suction I.D. 1-3/4 In., Line Connection Discharge I.D. 1-1/4 In., Refrigerant Type R-22, Nominal HP 7-1/2, 50/60 Hz, 24.1 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 9-1/2 In., Base Mount Width 9-1/2 In.Length 12-23/64 In. |
BRISTOL H22G094DBDE-R |
12N579 Grainger |
|
A/C Compressor, BtuH 90, 500, Voltage 208/230, 3 Phase, Line Connection Suction I.D. 1-1/8 In., Line Connection Discharge I.D. 7/8 In., Refrigerant Type R-22, Nominal HP 7-1/2, 50/60 Hz, 24.1 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 9-1/2 In., Base Mount Width 9-1/2 In.Length 12-23/64 In. |
BRISTOL H22G094DBDE-S |
12N580 Grainger |
|
A/C Compressor, BtuH 90, 500, Voltage 460, 3 Phase, Line Connection Suction I.D. 1-1/8 In., Line Connection Discharge I.D. 7/8 In., Refrigerant Type R-22, Nominal HP 7-1/2, 50/60 Hz, 12.3 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 9-1/2 In., Base Mount Width 9-1/2 In.Length 12-23/64 In. |
BRISTOL H22G094DBEE-S |
12N581 Grainger |
|
A/C Compressor, BtuH 92, 000, Voltage 208/230, 3 Phase, Line Connection Suction I.D. 1-1/8 In., Line Connection Discharge I.D. 3/4 In., Refrigerant Type R-22, Nominal HP 7-1/2, 50/60 Hz, 25.2 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 22-1/2 In., Base Mount Width 7-1/2 In.Length 12-23/64 In. |
BRISTOL H2DA923DBLL |
12N583 Grainger |
|
A/C Compressor, BtuH 102, 000, Voltage 208/230, 3 Phase, Line Connection Suction I.D. 1-1/8 In., Line Connection Discharge I.D. 7/8 In., Refrigerant Type R-22, Nominal HP 8, 50/60 Hz, 29.2 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 9-1/2 In., Base Mount Width 9-1/2 In.Length 12-23/64 In. |
BRISTOL H22G104DBDE-S |
12N584 Grainger |
|
A/C Compressor, BtuH 102, 000, Voltage 208/230, 3 Phase, Line Connection Suction I.D. 1-3/4 In., Line Connection Discharge I.D. 1-1/4 In., Refrigerant Type R-22, Nominal HP 8, 50/60 Hz, 29.2 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 9-1/2 In., Base Mount Width 9-1/2 In.Length 12-23/64 In. |
BRISTOL H22G104DBDE-R |
12N585 Grainger |
|
A/C Compressor, BtuH 102, 000, Voltage 460, 3 Phase, Line Connection Suction I.D. 1-1/8 In., Line Connection Discharge I.D. 7/8 In., Refrigerant Type R-22, Nominal HP 8, 50/60 Hz, 14.6 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 9-1/2 In., Base Mount Width 9-1/2 In.Length 12-23/64 In. |
BRISTOL H22G104DBEE-S |
12N586 Grainger |
|
A/C Compressor, BtuH 110, 000, Voltage 460, 3 Phase, Line Connection Suction I.D. 1-1/8 In., Line Connection Discharge I.D. 3/4 In., Refrigerant Type R-22, Nominal HP 10, 50/60 Hz, 15.2 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 22-1/2 In., Base Mount Width 7-1/2 In.Length 12-23/64 In. |
BRISTOL H2DA114DBEL |
12N587 Grainger |
|
A/C Compressor, BtuH 118, 000, Voltage 460, 3 Phase, Line Connection Suction I.D. 1-3/4 In., Line Connection Discharge I.D. 1-1/4 In., Refrigerant Type R-22, Nominal HP 10, 50/60 Hz, 16.8 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 9-1/2 In., Base Mount Width 9-1/2 In.Length 12-23/64 In. |
BRISTOL H22G124DBEE-R |
12N588 Grainger |
|
A/C Compressor, BtuH 118, 000, Voltage 460, 3 Phase, Line Connection Suction I.D. 1-1/8 In., Line Connection Discharge I.D. 7/8 In., Refrigerant Type R-22, Nominal HP 10, 50/60 Hz, 16.8 Amps, Evaporating Temp @ ARI Standards 45 Degrees F, Condensing Temp @ ARI Standards 130 Degrees F, Return Gas Temp @ ARI Standards 65 Degrees F, Ambient Temp @ ARI Standards 95 Degrees F, Liquid Temp @ ARI Standards 115 Degrees F, Base Mount Length 9-1/2 In., Base Mount Width 9-1/2 In.Length 12-23/64 In. |
BRISTOL H22G124DBEE-S |