Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
46E328 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 12-1/4, CFM @ 1.000-In. SP 2527, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 3.53, Motor HP 3, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 28-5/16, Housing Width (In.) 22-13/16, Housing Length (In.) 24-3/4, Discharge Height (In.) 8-9/16, Discharge Width (In.) 13-3/4, Inlet Dia. (In.) 12-7/8, Wheel Width (In.) 4-3/4 |
CHICAGO BLOWER 122-3HP |
46E329 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 15, CFM @ 1.000-In. SP 3784, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 5.72, Motor HP 5, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 29-5/16, Housing Width (In.) 27-7/16, Housing Length (In.) 29-11/16, Discharge Height (In.) 9-3/8, Discharge Width (In.) 16-11/16, Inlet Dia. (In.) 15-3/4, Wheel Width (In.) 5-1/4 |
CHICAGO BLOWER 150-5HP |
46E330 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 16-1/2, CFM @ 1.000-In. SP 4645, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 8.67, Motor HP 7-1/2, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 32, Housing Width (In.) 29-7/8, Housing Length (In.) 32-1/2, Discharge Height (In.) 10, Discharge Width (In.) 18-7/16, Inlet Dia. (In.) 17-5/8, Wheel Width (In.) 5-7/8 |
CHICAGO BLOWER 165-7.5HP |
46E331 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 16-1/2, CFM @ 1.000-In. SP 6330, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 11.5, Motor HP 10, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 33, Housing Width (In.) 29-7/8, Housing Length (In.) 32-1/2, Discharge Height (In.) 11-1/4, Discharge Width (In.) 18-7/16, Inlet Dia. (In.) 17-5/8, Wheel Width (In.) 5-7/8 |
CHICAGO BLOWER 165-10HP |
46E332 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 18-1/4, CFM @ 1.000-In. SP 7610, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 16.6, Motor HP 15, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 37-5/16, Housing Width (In.) 32-3/4, Housing Length (In.) 35-15/16, Discharge Height (In.) 11-3/4, Discharge Width (In.) 20-3/8, Inlet Dia. (In.) 19-5/8, Wheel Width (In.) 7-1/8 |
CHICAGO BLOWER 182-15HP |
46E333 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 18-1/4, CFM @ 1.000-In. SP 9960, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 21.9, Motor HP 20, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 38-5/16, Housing Width (In.) 32-3/4, Housing Length (In.) 35-15/16, Discharge Height (In.) 13-7/32, Discharge Width (In.) 20-3/8, Inlet Dia. (In.) 19-5/8, Wheel Width (In.) 7-1/8 |
CHICAGO BLOWER 182-20HP |
46E334 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 18-1/4, CFM @ 1.000-In. SP 11, 710, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 27.8, Motor HP 25, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 43-1/8, Housing Width (In.) 32-3/4, Housing Length (In.) 35-15/16, Discharge Height (In.) 14-1/4, Discharge Width (In.) 20-3/8, Inlet Dia. (In.) 19-5/8, Wheel Width (In.) 7-1/8 |
CHICAGO BLOWER 182-25HP |
46E335 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 20, CFM @ 1.000-In. SP 13, 169, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 33.2, Motor HP 30, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 43-5/16, Housing Width (In.) 35-11/16, Housing Length (In.) 39-1/4, Discharge Height (In.) 14-11/32, Discharge Width (In.) 22-3/8, Inlet Dia. (In.) 21-5/8, Wheel Width (In.) 7-3/4 |
CHICAGO BLOWER 200-30HP |
46E336 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 20, CFM @ 1.000-In. SP 15, 480, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 44.2, Motor HP 40, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 46-3/8, Housing Width (In.) 35-11/16, Housing Length (In.) 39-1/4, Discharge Height (In.) 15-5/8, Discharge Width (In.) 22-3/8, Inlet Dia. (In.) 21-5/8, Wheel Width (In.) 7-3/4 |
CHICAGO BLOWER 200-40HP |
46E337 Grainger |
|
High Pressure Blower, Backward Incline, Wheel Dia. (In.) 22-1/4, CFM @ 1.000-In. SP 18, 230, Max. Inlet Temp. (Deg. F) 150, Max. Ambient Temp. (F) 120, Voltage 230/460, Phase 3, Hz 60, Full Load Amps 54.7, Motor HP 50, Motor RPM 3600, Motor Enclosure Totally Enclosed Fan Cooled, Blower RPM 3500, Housing Height (In.) 46-11/16, Housing Width (In.) 39-3/8, Housing Length (In.) 43-1/2, Discharge Height (In.) 15-13/16, Discharge Width (In.) 24-7/8, Inlet Dia. (In.) 24-1/4, Wheel Width (In.) 8-13/16 |
CHICAGO BLOWER 222-50HP |