Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
1LYV6 Grainger |
|
Anemometer, Rotating Vane, Velocity 50 to 6000 FPM, Velocity 0.25 to 30 MPS, Air Volume 1 to 9999000 CFM, Temp Range 32 TO 140 F (0 to 60 C), Accuracy +/-1% of Reading + 4 FPM, Probe Size 4 In, Display 4 Digit LCD, Auto Power Off, Calibration Certificate NIST, Battery Type 9 V, Includes Battery, Carrying Case and Instructions |
ALNOR RVA801 |
1UCY4 Grainger |
|
Anemometer, Hot Wire, Velocity 0 to 4000 FPM, Temp Range 0 To 200 F, Accuracy +/-5% of Reading or +/- 5 FPM Whichever is Greater, Probe Size 40 In Telescoping, 0.28 In Diameter, Cord Length 39 In, Display LCD, Auto Power Off, NIST Calibration Certificate, Battery Type AA, Includes Batteries, Carrying Case and Instructions |
ALNOR AVM410 |
1UCY6 Grainger |
|
Anemometer, Hot Wire, Velocity 0 to 6000 FPM, Temp Range 0 To 200 F, Accuracy +/-3% of Reading or +/-3 FPM Whichever is Greater, Probe Size 42 In Articulated, 0.28 In Diameter, Cord Length 39 In, Display LCD, Data Hold, Auto Power Off, Storage Capacity 12, 700 Samples, NIST Calibration Certificate, Battery Type AA, Special Features Data Storage, Includes Batteries, Carrying Case, USB Cable, Software and Instructions |
ALNOR AVM430-A |
1UCY7 Grainger |
|
Anemometer, Hot Wire, Velocity 0 to 6000 FPM, Relative Humidity Range 0 - 95%, Dew Point Range 14 To 140 F, Temp Range 14 To 140 F, Accuracy +/-3% of Reading or +/-3 FPM Whichever is Greater, Probe Size 42 In Articulated, 0.28 In Diameter, Cord Length 39 In, Display LCD, Data Hold, Auto Power Off, Storage Capacity 12, 700 Samples, NIST Calibration Certificate, Battery Type AA, Special Features Relative Humidity, Data Storage, Includes Batteries, Carrying Case, USB Cable, Software and Instructions |
ALNOR AVM440-A |
3ATR7 Grainger |
|
Air Flow Capture Hood, Digital, Hoods Included 2 x 2, 25 to 2500 CFM Range, Accuracy +/-3 Percent of Reading, Multi Line LCD Display, Base Dimension (In.) 18 In. x 18, Height (In.) 42, Velocity Range (FPM) 25 to 15, 500, Absolute Pressure Range 15 To 40 In. Hg, 26, 500 Readings Data Storage, Differential Pressure Range +/-15 In. WC, Relative Humidity Range 0 To 95 Percent, Temp. Range -40 to 140 F, Battery Type AA Size NiMH Batteries, Minimum 10 Hours Battery Life |
ALNOR EBT731 |
3ATR8 Grainger |
|
Air Flow Capture Hood, Analog, Hoods Included 2 x 2, 0 to 1000 CFM Range, Accuracy +/-3% of Full Scale, Analog Meter Display, Base Dimension 18 In x 18 In, Height 42 In, Minimum 12 Hours Battery Life, Includes Base, Meter, 2 x 2 hood, Case, Batteries and Instructions |
ALNOR ABT701 |
3ATR9 Grainger |
|
Velocity Matrix Probe, Range 25 to 8000 FPM, Accuracy +/-3% of Reading +/- 7 FPM, For Use With 3ATR7, Includes (2) 8 Ft Hoses, Telescopic Handle and Stand Offs |
ALNOR 801090 |
3ATT1 Grainger |
|
Air Flow Probe, Range 25 to 8000 FPM, Accuracy +/-3% of Reading +/- 7 FPM, For Use With 3ATR7 |
ALNOR 800187 |
3ATT2 Grainger |
|
Temperature And Humidity Probe, Range Temp -40 to 250 F, RH 0 to 95%, Accuracy Temp +/-0.5 F, RH +/-3%, For Use With 3ATR7, Includes NIST Certificate |
ALNOR 800219 |
3DTD9 Grainger |
|
Temperature Probe, Range -40 to 250 F, Accuracy +/-0.5 F, For Use With 3ATR7, Includes NIST Certificate |
ALNOR 800188 |