7M7U5 7M7U5
DAYTON
Roof Vent, 14 3/4 In, w/ 3/4 HP Drive Pkg
Exhaust Ventilator, High Presure, Centrifugal Upblast, With Drive Package, Wheel Dia 14 3/4 In, CFM @ 0.500-In SP 1592, @ 0.750-In SP 1536, @ 1.000-In SP 1473, @ 1.250-In SP 1409, @ 1.500-In SP 1341, Sones @ 0.500-In SP @ 5 Ft 19.8, Max Inlet Temp 300 Deg F, Motor Voltage 208/230-460, 3 Phase, Max Operating Amps 2.8-2.7/1.4, Motor 3/4 HP, RPM 2110, Roof Mounting Location, Base Width 26 In, Base Length 26 In, Requires Roof Curb For New Installation, Includes NEMA 1 Junction Box
Артикул:
7M7U6
Каталог:
Grainger
Производитель:
DAYTON
Номер модели:
7M7U6
Страна производства:
Not Available
Вес (кг):
37.60

Спецификация:
| Item: Centrifugal Upblast Exhaust Ventilator |
| Type: Standard Duty, High Pressure |
| Style: Unassembled With Drive Package |
| Wheel Dia. (In.): 14-3/4 |
| Wheel Type: Backward Incline |
| CFM @ 0.500-In. SP: 1592 |
| CFM @ 0.750-In. SP: 1536 |
| CFM @ 1.000-In. SP: 1473 |
| CFM @ 1.250-In. SP: 1409 |
| CFM @ 1.500-In. SP: 1341 |
| CFM @ 1.75-In. SP: 1262 |
| CFM @ 2.000-In. SP: 1178 |
| CFM @ 2.250-In. SP: 1073 |
| CFM @ 2.500-In. SP: 965 |
| CFM @ 2.75-In. SP: 804 |
| Sones @ 0.500-In. SP @ 5 Ft.: 19.8 |
| Max. Inlet Temp. (Deg. F): 300 |
| Motor Voltage: 208-230/460 |
| Motor Hz: 60 |
| Phase: 3 |
| Max. Operating Amps: 2.8-2.7/1.4 |
| Bearing Type: Regreasable Pillow Block |
| Motor HP: 3/4 |
| Max. BHP: 0.78 |
| RPM: 2110 |
| Speed Controllable: No |
| Mounting Location: Roof |
| Base Width (In.): 26 |
| Base Length (In.): 26 |
| Base Height (In.): 1-3/4 |
| Overall Height (In.): 28-1/8 |
| Overall Dia. (In.): 28-7/8 |
| Shaft Dia. Wheel End (In.): 3/4 |
| Shaft Dia. Sheave End (In.): 3/4 |
| Housing Material: Spun Aluminum |
| Wheel Material: Aluminum |
| Agency Compliance: UL/cUL 705/762 |
| Requires: Roof Curb For New Installation |
| Includes: NEMA 1 Junction Box |
| Adj. 12 3/8"H Roof Curb Stock No.: 2ZV83 |
| Adj. 6 3/8"H Roof Curb Stock No.: 3C437 |
| Recommended 12 In. Fixed Curb Item No.: 2RB77 |
| Recommended 8 In. Fixed Curb Item No.: 4HX40 |
| Fixed UL 762 Kitchen Roof Curb Stock No.: 4HX56 |
| Adj. UL 762 Kitchen Roof Curb Stock No.: 4HX62 |
| Recommended Damper Size (In.): 19 x 19 |
| Recommended Damper Stock No.: 4HX66 |
Альтернативная продукция:
Exhaust Ventilator, High Presure, Centrifugal Upblast, With Drive Package, Wheel Dia 14 3/4 In, CFM @ 0.500-In SP 1363, @ 0.750-In SP 1292, @ 1.000-In SP 1219, @ 1.250-In SP 1137, @ 1.500-In SP 1042, Sones @ 0.500-In SP @ 5 Ft 17, Max Inlet Temp 300 Deg F, Motor Voltage 208/230-460, 3 Phase, Max Operating Amps 2.0-2.0/1.0, Motor 1/2 HP, RPM 1845, Roof Mounting Location, Base Width 26 In, Base Length 26 In, Requires Roof Curb For New Installation, Includes NEMA 1 Junction Box