ТЕЛ:+7 (985) 487-07-35
WhatsApp / Telegram: +7 (916) 211-71-00
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

AC Drive, 7 1/2 HP

AC Drive, Motor Power Rating 7 1/2 HP, Output Current 22.0 Amps, Height 10.3 Inches, Width 8.7 Inches, Depth 7.7 Inches, 200 to 230 VAC, 50/60 hz, NEMA 4, Three Phase Input
Артикул:
5HV41
Каталог:
Grainger
Производитель:
FUJI
Номер модели:
FRN007P11W-2UX
Страна производства:
Not Available
Вес (кг):
7.09
5HV41 AC Drive, 7 1/2 HP
Спецификация:
Item: AC Drive
Drive Type: Adjustable Frequency Variable Torque
Max. HP: 7-1/2
Max. Output Amps: 22.0
Voltage: 200-230
Input Phase AC: 3
Height (In.): 10.3
Width (In.): 8.7
Depth (In.): 7.70
Functions: Operating Method/Frequency Setting, Base and Top Frequency, Maximum Output Frequency, Torque Boost, Fault Memory, DC Braking, Acceleration/Deceleration, Motor Sound Adjustment, Maximum Output Voltage, Slip Compensation, Torque Limit Control, Sensorless Torque Vector, Jump Frequency, Automatic Deceleration Time, Automatic Pattern Operation
Protection: Overcurrent, Overvoltage, Undervoltage, Inverter Heatsink and Brake Resistor Overheating
Displays: Input Volts, Output Amps, RPM, Frequency or Conveyor Speed

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
4XJJ1
Grainger
Подробнее... Output Filter, dV/dT, Voltage 600V & Below, Amps 25, HP 15, Phase Three, Enclosure Type Open, Watts Loss 110, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is 100 Ft. to 1000 Ft., Height 9 In., Width 5.5 In., Depth 8.25 In., Standards UL Listed, CE certified V1K FILTERS
V1K25A00
4XJL9
Grainger
Подробнее... Output Filter, dV/dT, Voltage 600V & Below, Amps 25, HP 15, Phase Three, Enclosure Type UL Type 1, Watts Loss 110, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is 100 Ft. to 1000 Ft., Height 9 In., Width 5.5 In., Depth 10 In., Standards UL Listed, CE certified V1K FILTERS
V1K25A01
4XJR6
Grainger
Подробнее... Input Line Reactor, Low Z, Voltage 208/240, Amps 24.2, 7.5 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 48, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULB23LE01
4XRL5
Grainger
Подробнее... Input Line Reactor, Low Z, Voltage 208/240, Amps 24.2, HP 7.5, Phase Three, Enclosure Type Open, Watts Loss 48, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 5 In., Width 6 In., Depth 4 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULB23L
4XRP8
Grainger
Подробнее... Input Line Reactor, High Z, Voltage 208/240, Amps 24.2, HP 7.5, Phase Three, Enclosure Type Open, Watts Loss 66.5, Impedance 5%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 5 In., Width 6 In., Depth 4 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULB26H
Обратите внимание:
3XA43
Drive, AC, 3 HP
4LRJ8
AC Drive, Var.Freq., 1HP, 3A, 480VAC
4UAG4
ACDrive, Var.Freq, 15HP, 24A, 380-480V, 3PH
5HV28
AC Drive, 30 HP