4HZ45 4HZ45
DAYTON
Exhaust Vent, 14 3/4 In
Exhaust Ventilator, Centrifugal Upblast Direct Drive, CFM @ 0.000-In SP 2065, @ 0.250-In SP 1864, @ 0.500-In SP 1605, 11.0 Sones @ 0.250-In SP, Roof Mounting Location, Base Width 26 In, Base Length 26 In, Max Inlet Temp 300 F, Motor Voltage 115, 1 Phase, Motor HP 1/4, 1140 RPM, Wheel Dia 14 3/4 In, Speed Controllable Except For Kitchen Applications, Requires Roof Curb For New Installation, Includes NEMA 1 Junction Box
Артикул:
4HZ49
Каталог:
Grainger
Производитель:
DAYTON
Номер модели:
4HZ49
Страна производства:
USA
Вес (кг):
27.27
![](/img/ajax.gif)
Спецификация:
Item: Upblast Exhaust Ventilator |
Number of Speeds: 1 |
Wheel Dia. (In.): 14-3/4 |
CFM @ 0.000-In. SP: 2065 |
CFM @ 0.125-In. SP: 1973 |
CFM @ 0.250-In. SP: 1864 |
CFM @ 0.375-In. SP: 1745 |
CFM @ 0.500-In. SP: 1605 |
CFM @ 0.625-In. SP: 1430 |
CFM @ 0.750-In. SP: 1167 |
Sones @ 0.250-In. SP @ 5 Ft.: 11.0 |
Motor Voltage: 115 |
Phase: 1 |
Hz: 60 |
Max. Operating Amps: 3.2 |
Motor HP: 1/4 |
Max. BHP: 0.29 |
RPM: 1140 |
Base Width (In.): 26 |
Base Length (In.): 26 |
Base Height (In.): 1-3/4 |
Overall Dia. (In.): 28-3/8 |
Overall Height (In.): 30-1/2 |
Shaft Dia. Wheel End (In.): 1/2 |
Mounting Location: Roof |
Max. Inlet Temp. (Deg. F): 300 |
Housing Material: Spun Aluminum |
Wheel Material: Aluminum |
Wheel Type: Backward Incline |
Speed Control: 1DGV2 |
Speed Controllable: at 115 Volt Only |
Agency Compliance: UL/cUL 705/762 |
Requires: Roof Curb For New Installation |
Includes: NEMA 1 Junction Box |
Adj. 12 3/8"H Roof Curb Stock No.: 2ZV83 |
Adj. 6 3/8"H Roof Curb Stock No.: 4C454 |
Recommended 12 In. Fixed Curb Item No.: 4HX48 |
Recommended 8 In. Fixed Curb Item No.: 4HX40 |
Fixed UL 762 Kitchen Roof Curb Stock No.: 4HX56 |
Adj. UL 762 Kitchen Roof Curb Stock No.: 4HX62 |
Recommended Damper Size (In.): 19 x 19 |
Recommended Damper Stock No.: 4HX66 |
Альтернативная продукция:
Exhaust Ventilator, Centrifugal Upblast Direct Drive, CFM @ 0.000-In SP 2366, @ 0.250-In SP 2244, @ 0.500-In SP 2122, 18.4 Sones @ 0.250-In SP, Roof Mounting Location, Base Width 22 In, Base Length 22 In, Max Inlet Temp 300 F, Motor Voltage 115/230, 1 Phase, Motor HP 3/4, 1725 RPM, Wheel Dia 13 1/4 In, Speed Controllable Except For Kitchen Applications, Requires Roof Curb For New Installation, Includes NEMA 1 Junction Box
Exhaust Ventilator, Centrifugal Upblast Direct Drive, CFM @ 0.000-In SP 1558, @ 0.250-In SP 1264, 7.1 Sones @ 0.250-In SP, Roof Mounting Location, Base Width 26 In, Base Length 26 In, Max Inlet Temp 300 F, Motor Voltage 115, 1 Phase, Motor HP 1/8, 860 RPM, Wheel Dia 14 3/4 In, Speed Controllable Except For Kitchen Applications, Requires Roof Curb For New Installation, Includes NEMA 1 Junction Box
Exhaust Ventilator, Centrifugal Sidewall Direct Drive, CFM @ 0.000-In SP 2065, @ 0.250-In SP 1864, @ 0.500-In SP 1605, 10.9 Sones @ 0.250-In SP, Wall Mounting Location, Base Width 22 1/8 Dia In, Base Length 22 1/8 Dia In, Max Inlet Temp 300 F, Motor Voltage 115, 1 Phase, Motor HP 1/4, 1140 RPM, Wheel Dia 14 3/4 In, Speed Controllable Except For Kitchen Applications, Includes NEMA 1 Junction Box
Exhaust Ventilator, Centrifugal Upblast Direct Drive, CFM @ 0.000-In SP 2472, @ 0.250-In SP 2126, @ 0.500-In SP 1680, 9.9 Sones @ 0.250-In SP, Roof Mounting Location, Base Width 26 In, Base Length 26 In, Max Inlet Temp 300 F, Motor Voltage 115, 1 Phase, Motor HP 1/4, 860 RPM, Wheel Dia 16 1/2 In, Speed Controllable Except For Kitchen Applications, Requires Roof Curb For New Installation, Includes NEMA 1 Junction Box