AC Adj Frequency Drive, 1/4 HP, 3 Ph, 230V

AC Drive, Adjustable Frequency, Max HP 1/4, Max Output Amps 3.0, 200-230 Voltage Input, 200-230 Voltage Output, Input Phase AC 3, Output Phase AC 3, Starting Torque 200 %, Torque @ 1 Hz 200 %, Frequency Setting 50/60 Hertz, Output Frequency 0-400 Hertz, Acceleration Adjust 0.1-3000 Sec, Deceleration Adjust 0.1-3000 Sec, Dynamic Braking, Open Enclosure, Height 4 1/2 In, Width 5 1/8 In, Depth 5 3/8 In, Agency Compliance cULus, CE
Артикул:
1KBP9
Каталог:
Grainger
Производитель:
DAYTON
Номер модели:
1KBP9
Страна производства:
South Korea
Вес (кг):
1.61
1KBP9 AC Adj Frequency Drive, 1/4 HP, 3 Ph, 230V
Спецификация:
Item: AC Drive
Drive Type: Adjustable Frequency
Max. HP: 0.25
Max. Output Amps: 1.6
Voltage: 200-230
Voltage Output: 200-230
Input Phase AC: 3
Output Phase AC: 3
Frequency Setting (Hertz): 50/60
Output Frequency (Hertz): 0 to 400
Acceleration Adjust (Sec.): 0.1 - 3000
Deceleration Adjust (Sec.): 0.1 - 3000
Dynamic Braking: Yes
Enclosure: Open
Functions: Multispeed Operation, Operation Mode Selection (V/F Control or Sensorless Vector Control Method Selection Programmable), DC Braking, Dynamic Braking, Upper/Lower Frequency Setting, Frequency Jump Operation, PID Control, Automatic Voltage Regulation, Forward/Reverse/Run, Acceleration/Deceleration (Linear, S-Curve or U-Curve Pattern Selectable), Instantaneous Power Failure Restart Operation, Electronic Thermal Level Adjustment, Retry Function, Trip History Monitor, Auto Tuning, Torque Boost, Overload Advance Notice Signal, Software Lock, Carrier Frequency Adjustment, RS485 Link Operation, Starting Frequency Adjustment, Jogging Operation
Control Type: Keypad/Potentiometer
Key Pad Lockout: Yes
Start/Stop Control: Programmable
Protection: Overcurrent, Overvoltage, Undervoltage, Output Short Circuit, Temperature Abnormality, Overload Shut-Off (Electronic Thermal), Ground Fault Protection, External Trip, Communication Error, Unattended Start Prevention Error, EEPROM Error
Control Method: Space Vector PWM Control
Displays: LED
Digital Readout: RPM, Output Frequency, Output Current, Output Voltage, Operation Direction, PID Feedback, Terminal Input, Terminal Output, Transition Frequency Monitor, Power Consumption and Operating Time Accumulation
For Use With: 3-Phase Inverter Duty Motors
Agency Compliance: cULus, CE
Green Environmental Attribute: Product Contributes To Reducing Energy Consumption

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
4XJL1
Grainger
Подробнее... Output Filter, dV/dT, Voltage 600V & Below, Amps 3, HP 1.5, Phase Three, Enclosure Type UL Type 1, Watts Loss 75, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is 100 Ft. to 1000 Ft., Height 9 In., Width 5.5 In., Depth 10 In., Standards UL Listed, CE certified V1K FILTERS
V1K3A01
4XJP8
Grainger
Подробнее... Input Line Reactor, Low Z, Voltage 208/240, Amps 2.4, 0.5 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 7, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA54LE01
4XRK7
Grainger
Подробнее... Input Line Reactor, Low Z, Voltage 208/240, Amps 2.4, HP 0.5, Phase Three, Enclosure Type Open, Watts Loss 7, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 4 In., Width 4.18 In., Depth 3.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA54L
4XRP1
Grainger
Подробнее... Input Line Reactor, High Z, Voltage 208/240, Amps 2.4, HP 0.5, Phase Three, Enclosure Type Open, Watts Loss 14, Impedance 5%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 4 In., Width 4.18 In., Depth 3.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA54H
4XTU9
Grainger
Подробнее... Output Filter, dV/dT, Voltage 600V & Below, Amps 3, HP 1.5, Phase Three, Enclosure Type Open, Watts Loss 75, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is 100 Ft. to 1000 Ft., Height 9 In., Width 5.5 In., Depth 7.25 In., Standards UL Listed, CE certified V1K FILTERS
V1K3A00
Обратите внимание:
12T617
VFD, 2HP, 3A, 460V, 3 Ph In, 3 Ph Out
14H054
Enclosed Drive, By-pass/Contactor, Amp 4.8
33M567
460V, 3-Phase, 5HP, 9A, FRENIC-MEGA
6MVC2
Variable Frequency Drive, 400-480VAC, 5HP