Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
15E589 Grainger |
|
Moisture Content Meter/Datalogger, SD card, Moisture Content 10 to 95 Percent, Moisture Content Accuracy 3 Percent, Temp. Range (F) 32 to 122, Display Dual backlit LCD, Cable Length (Ft.) 4.9, Data Hold Yes, Dew Point Range (F) -13 to 120, 2G Memory, Interface SD Card and RS-232, Min./Max. Memory Yes, Battery Type 9V, Includes Moisture Content Probe W 4.9ft (1.5m) Cable, Sensor Cap, SD Card, 9V Battery, Carrying Case, and Instructions, Manufacturers Warranty Length 3 Years |
EXTECH SDL550 |
15E590 Grainger |
|
Light Meter, All Visible Light Lighting Types, Measuring Range 10, 000 Foot Candles, Resolution 0.1Fc/1Lux, Accuracy +/-4 Percent reading, Display 9, 999 Count Backlit LCD, Data Hold Yes, Min./Max. Memory Yes, Data Logging 20M Readings, Interface SD Card and RS-232, 2G SD Card Memory, Auto Power Off Yes, AA Battery Type, Photo Diode and Color Correction Filter, Spectrum Designed to Meet CIE Sensor, Cord Length 39 In. (1m), NIST Certificate included Calibration Certificate |
EXTECH SDL400-NIST |
15E591 Grainger |
|
Temperature Humidity Meter10 to 95 Percent Relative Humidity Range, 0.04 Humidity Accuracy, Thermistor 32 Degrees to 122 Degrees F, Type K -148 Degrees to 2372 Degrees F Temp. Range (F), 1 Percent, 2 Degrees F Temp. Accuracy (F)Type K: -148 Degrees to 2372 Degrees F Surface Temp. (F), 0.1 Percent Humidity Resolution, Sensor Type Thermistor, Display Dual LCDMemory Min/Max, Battery Type (6) 1.5V AAA, Auto Power Off Yes |
EXTECH EN300 |
15E593 Grainger |
|
Indoor Air Quality Monitor, Carbon Dioxide, Temp. Range (F) 14 to 140, Relative Humidity Range 0.1 to 99.9, Sample Point Storage 5333 points, Digital Readout Multifunction LCD, AC Adapter Included, Time Intervals 1 second to 4hr:59min:59sec, Alarm High and Low Audible Alarms, Width (In.) 4.6, Depth (In.) 4, Height (In.) 4, Software Required Included, Special Features Maintenance Free NDIR Sensor, Interface RS-232, Includes Universal AC Adaptor, Software, Cable and Instructions |
EXTECH CO210 |
15E594 Grainger |
|
Fruit Hardness Tester, Digital Penetrometer, Range 44.10lbs, 20kg, 196.10 Newtons, Accuracy (0.5 Percent + 2 digits), Resolution 0.01lbs, 0.01kg, 0.05 Newtons, Function Fast/Slow Update Rate; Peak Hold, Features Tension or Compression, Peak Hold, Zero Function, Backlit LCD, Length 8.5, Width 3.5, Height 1.8, Dia. 3mm. 5mm, 8mm, and 11mm tips, Includes Four (3mm, 5mm, 8mm, 11mm) Penetrometer Tips, (6) AA 1.5V batteries, Carrying Case and Instructions, Manufacturers Warranty Length 1 Year |
EXTECH FHT200 |
15E599 Grainger |
|
Temperature PID Controller, 1/16 DIN, Thermocouple and RTD Sensor Type, Input Voltage 1 to 5VDC, Length (In.) 1.77, Width (In.) 1.77, Depth (In.) 3.94, 5A Amps, Control Mode Fuzzy Logic Enhanced Three-term PID with Auto Tune; Proportional Band; Derivative Time; Hysteresis; Cycle Time, Control Period Proportional Band 0 to 300.0 Percent; Integral time 0 to 3600 seconds; Derivative time 0 to 900 seconds; Hysteresis 0.0 to 200.0 or 0.0 to 2000; Cycle time 1 to 100 second, One-touch Auto Tuning |
EXTECH 48VFL11 |
15E601 Grainger |
|
Temperature PID Controller, 1/16 DIN, Thermocouple and RTD Sensor Type, Input Voltage 1 to 5VDC, Length (In.) 1.77, Width (In.) 1.77, Depth (In.) 3.94, 4-20mA Amps, Control Mode Fuzzy Logic Enhanced Three-term PID with Auto Tune; Proportional Band; Derivative Time; Hysteresis; Cycle Time, Control Period Proportional Band 0 to 300.0 Percent; Integral time 0 to 3600 seconds; Derivative time 0 to 900 seconds; Hysteresis 0.0 to 200.0 or 0.0 to 2000; Cycle time 1 to 100 second, One-touch Auto Tuning |
EXTECH 48VFL13 |
15E602 Grainger |
|
Temperature PID Controller, 1/4 DIN, Thermocouple and RTD Sensor Type, Input Voltage 1 to 5VDC, Length (In.) 3.62, Width (In.) 3.62, Depth (In.) 3.15, 5A Amps, Control Mode Fuzzy Logic Enhanced Three-term PID with Auto Tune; Proportional Band; Derivative Time; Hysteresis; Cycle Time, Control Period Proportional Band 0 to 300.0 Percent; Integral time 0 to 3600 seconds; Derivative time 0 to 900 seconds; Hysteresis 0.0 to 200.0 or 0.0 to 2000; Cycle time 1 to 100 second, One-touch Auto Tuning |
EXTECH 96VFL11 |
15E603 Grainger |
|
Temperature PID Controller, 1/4 DIN, Thermocouple and RTD Sensor Type, Input Voltage 1 to 5VDC, Length (In.) 3.62, Width (In.) 3.62, Depth (In.) 3.15, 4-20mA Amps, Control Mode Fuzzy Logic Enhanced Three-term PID with Auto Tune; Proportional Band; Derivative Time; Hysteresis; Cycle Time, Control Period Proportional Band 0 to 300.0 Percent; Integral time 0 to 3600 seconds; Derivative time 0 to 900 seconds; Hysteresis 0.0 to 200.0 or 0.0 to 2000; Cycle time 1 to 100 second, One-touch Auto Tuning |
EXTECH 96VFL13 |
15X977 Grainger |
|
Energy Audit Kit, Includes Mfr. No. MO290 Pinless Moisture Psychrometer Plus InfraRed Thermometer, Patented InfraRed Thermometer with Laser Pointer for Non Contact Surface Temperature Measurement, Pin Probe, AN200 CFM, CMM Mini Thermo Anemometer Plus Infrared Thermometer, CO250 Portable Indoor Air Quality CO2 Meter, Datalogger, Cable to Analyze Data On Your PC, BR200 Video Borescope, Wireless Inspection Camera, MicroSD Memory Card, Heavy Duty Hard Carrying Case |
EXTECH MO290-EK |