1LYP9 Grainger |
|
Infrared Thermometer, Temp. Range (F) -58 Degrees to 1100 Degrees F, Temp. Range (C) -50 Degrees to 600 Degrees C, Focus Spot Size and Distance 1 In. @ 8 In., Accuracy +/-4 Degrees F or +/-2 Percent, Emissivity Fixed 0.95, Laser Sighting Single Dot, Battery Type 9VData Hold Yes, Display Backlit LCD, Resolution 0.1 Degrees Up to 200 Degrees , Spectral Response 6 to 14 uM, Response Time 500 msec.Operating Temp. Range 32 Degrees to 122 Degrees F, Standards Class II Laser, Trigger Push Button |
EXTECH EZ20 |
1LYR2 Grainger |
|
Process Calibrator, Current, Source Current 0 to 24mADC, Current Measurement Range 0 to 50mADC, Accuracy +/-0.075% +/-1 Digit, Loop Supply Voltage 24VDC, Display 2000 Count LCD, Powered By 9V Battery, Includes Battery, Calibration Cable with Spade Lugs, Instructions |
EXTECH 412300A |
1LYR3 Grainger |
|
Process Calibrator, Current and Voltage, Source Voltage 0 to 10VDC, Voltage Measurement Range 0 to 20VDC, Source Current 0 to 24mADC, Current Measurement Range 0 to 50mADC, Accuracy +/-0.075% +/-1 Digit, Display 2000 Count LCD, Powered By 9V Battery, Includes Battery, Calibration Cable with Spade Lugs, Instructions |
EXTECH 412355A |
1LYR4 Grainger |
|
Process Calibrator, Current, Voltage, and Temp Calibrator/Meter, Source Voltage 0 to 10.00VDC, Voltage Measurement Range 0 to 19.99VDC, Source Current 0 to 24.00mADC, Current Measurement Range 0 to 50.0 mADC, Accuracy +/-0.075% +/-1 Digit, Thermocouple Type J, K and T, Thermocouple Temperature Range -184 to 3182 F (-120 to 1800 C), Loop Supply Voltage 24VDC, Display 2000 Count LCD, Powered By 6 AA Batteries or AC Adaptor, Includes Batteries, Calibration Cable with Spade Lugs, Instructions |
EXTECH 412400 |
1LYR5 Grainger |
|
Thermocouple Thermometer, Thermocouple Type Type K, Number of Inputs 1, Probe Connector Mini-Type, Temp. Range (F) -58 Degrees to 1999 Degrees F, Temp. Range (C) -50 Degrees to 1300 Degrees C, Accuracy 0.3 Percent of Reading, Display Backlit 3 Line LCD, Resolution 0.1 Degrees , 1 Degrees Sampling Rate -, Data Logging 150 Points, Battery Type (6) AAA, Auto Power Off Yes, Data Hold Yes, Memory Min/Max/Avg/DifStandards CE, Includes Protective Holster and Instructions |
EXTECH EA11A |
1LYR6 Grainger |
|
Thermocouple Thermometer, Thermocouple Type Type K, Number of Inputs 1, Probe Connector Mini-Type, Temp. Range (F) -58 Degrees to 1999 Degrees F, Temp. Range (C) -50 Degrees to 1300 Degrees C, Accuracy 0.3 Percent of Reading, Display Backlit 3 Line LCD, Resolution 0.1 Degrees , 1 Degrees Sampling Rate -, Data Logging 150 Points, Battery Type (6) AAA, Auto Power Off Yes, Data Hold Yes, Memory Min/Max, NIST Calibration Certificate, Standards CE, Includes Protective Holster and Instructions |
EXTECH EA11A-NIST |
1LZN7 Grainger |
|
Electrician Kit, Includes Mfr. No. EX530 CAT IV 600V Digital Multimeter, DV20 Non Contact AC Voltage Detector (100 to 600VAC) with Built In Flashlight, (8) Piece CAT III-1000V Electrical Test Lead Kit, Protective Storage Case and Instructions |
EXTECH EX530-KIT |
1LZN8 Grainger |
|
Digital Multimeter, Max. AC Volts 1000, Max. DC Volts 1000, Max. AC Amps 20, Max. DC Amps 20, Max. Ohms 60 M Ohms, Basic DC Accuracy 0.0009, Counts 6000, Battery Type 9V Alkaline, Safety Rating CAT IV 600V, Audible Continuity Yes, AC Response True RMS, Capacitance Range 1000uF, Frequency Counter Range 40 MHz, NIST Calibration Certificate, Includes (8) Pc. Electrical Test Lead Kit, Protective Storage Case |
EXTECH EX520-S |
1M928 Grainger |
|
Process Calibrator, Thermocouple Temperature, Source Voltage -5mV to 55mV, Voltage Measurement Range -5 to 55mVDC, Source Current -, Current Measurement Range -, Accuracy +/-0.15 Percent of Reading +/-1 Degree, Thermocouple Type J, K, T, E, C, R, S, N, Thermocouple Temperature Range -184 to 2498 F (-270 to 1370 C), RTD Type -, RTD Temperature Range -, Frequency Source Range -, Frequency Measurement Range -, Resistance Source -, Resistance Measurements -, Supply Pressure (PSI) - |
EXTECH 433201-NIST |
1M930 Grainger |
|
Process Calibrator, Thermocouple Temperature, Source Voltage -5mV to 55mV, Voltage Measurement Range -5 to 55mVDC, Source Current -, Current Measurement Range -, Accuracy +/-0.15 Percent of Reading +/-1 Degree, Thermocouple Type J, K, T, E, C, R, S, N, Thermocouple Temperature Range -184 to 2498 F (-270 to 1370 C), RTD Type -, RTD Temperature Range -, Frequency Source Range -, Frequency Measurement Range -, Resistance Source -, Resistance Measurements -, Supply Pressure (PSI) - |