Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
13G591 Grainger |
|
Battery Power Source, For Use With Fluke 190 Series II ScopeMEter Test Tools, Includes Battery Pack, Manufacturers Warranty Length 1 Year |
FLUKE BP290/WWG |
13G592 Grainger |
|
Hanging Hook, For Use With Fluke 190 Series II ScopeMeter Test Tools, Includes Hanging Hook, Manufacturers Warranty Length 1 Year |
FLUKE HH290/WWG |
13T379 Grainger |
|
Thermal Imager, Temp. Range -4 Degrees to +482 Degrees F (-20 Degrees to + 250 Degrees C), IR Detector Resolution 160 x 120 (19, 200) Pixels, Thermal Sensitivity Less Than or Equal To 0.10 Degrees C at 30 Degrees C Target Temp (100 mK), Picture In Picture Yes, Laser Sighting Yes, Temp. Accuracy +/- 2 Degrees C or 2 Percent (at 25 Degrees C Nominal, Whichever Is Greater)Visual Light Resolution 2 Megapixels, Industrial Grade, Display 3.5 In. (Diagonal) Color 640 x 480 LCD |
FLUKE FLK-TI100 9HZ/WWG |
13T380 Grainger |
|
Thermal Imager, Temp. Range -4 Degrees to +482 Degrees F (-20 Degrees to + 250 Degrees C), IR Detector Resolution 160 x 120 (19, 200) Pixels, Thermal Sensitivity Less Than or Equal To 0.10 Degrees C at 30 Degrees C Target Temp (100 mK), Picture In Picture Yes, Laser Sighting Yes, Temp. Accuracy +/- 2 Degrees C or 2 Percent (at 25 Degrees C Nominal, Whichever Is Greater)Alarm High Temperature Color Alarm, Visual Light Resolution 2 Megapixels, Industrial Grade, Display 3.5 In. (Diagonal) Color 64 |
FLUKE FLK-TI110 30HZ/WWG |
13T381 Grainger |
|
Thermal Imager, Temp. Range -4 Degrees to +302 Degrees F (-20 Degrees to +150 Degrees C), IR Detector Resolution 160 x 120 (19, 200) Pixels, Thermal Sensitivity Less Than or Equal To 0.08 Degrees C at 30 Degrees C Target Temp (80 mK), Picture In Picture Yes, Laser Sighting Yes, Temp. Accuracy +/- 2 Degrees C or 2 Percent (at 25 Degrees C Nominal, Whichever Is Greater)Alarm Low Temperature (Dewpoint) Color Alarm, Visual Light Resolution 2 Megapixels, Industrial Grade, Display 3.5 In. (Diagonal) |
FLUKE FLK-TIR110 9HZ/WWG |
13T382 Grainger |
|
Thermal Imager, 30 Hz, Temp. Range -4 Degrees to +662 Degrees F (-20 Degrees to +350 Degrees C), IR Detector Resolution 160 x 120 (19, 200) Pixels, Thermal Sensitivity Less Than or Equal To 0.10 Degrees C at 30 Degrees C Target Temp (100 mK), Picture In Picture Yes, Laser Sighting Yes, Temp. Accuracy +/- 2 Degrees C or 2 Percent (at 25 Degrees C Nominal, Whichever Is Greater)Alarm High Temperature, Low Temperature, Isotherm Alarm, Visual Light Resolution 2 Megapixels, Industrial Grade |
FLUKE FLK-TI125 30HZ/WWG |
13T383 Grainger |
|
Thermal Imager, Temp. Range -4 Degrees to +302 Degrees F (-20 Degrees to +150 Degrees C), IR Detector Resolution 160 x 120 (19, 200) Pixels, Thermal Sensitivity Less Than or Equal To 0.08 Degrees C at 30 Degrees C Target Temp (80 mK), Picture In Picture Yes, Laser Sighting Yes, Temp. Accuracy +/- 2 Degrees C or 2 Percent (at 25 Degrees C Nominal, Whichever Is Greater)Alarm High Temperature, Low Temperature, Isotherm Alarm, Visual Light Resolution 2 Megapixels, Industrial Grade |
FLUKE FLK-TIR125 9HZ/WWG |
13T384 Grainger |
|
Tripod Holder, For Use With FLUKE Ti100, Ti110, Ti125, TiR110, TiR125 |
FLUKE FLK-TI-TRIPOD2/WWG |
13T385 Grainger |
|
Sun Visor, For Use With FLUKE Ti100, Ti110, Ti125, TiR110, TiR125 |
FLUKE FLK-TI-VISOR2/WWG |
16L006 Grainger |
|
Pressure Calibrator, Multifunction, Source Voltage 24V Loop Power Supply, Voltage Measurement Range No, Source Current No, Current Measurement Range 0 to 24 mA, Accuracy 0.015 Percent, Thermocouple Type No, Thermocouple Temperature Range No, RTD Type No, RTD Temperature Range No, Frequency Source Range No, Frequency Measurement Range No, Resistance Source No, Resistance Measurements No, Supply Pressure (PSI) No, External Pressure Range 29 ranges 0 to 10, 000 psi |
FLUKE FLUKE-717 15G |