Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
18C850 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 2, Lamp Type T8, Lamp Length 48 In., Voltage 120-277, Height 1 In., Width 1-5/32 In., Length 14-1/8 In., Input Watts 66.5/67.2/68.4Number of F32T8 Lamps 2, Number of F32T8U Lamps 2Amps AC 0.24/0.28/0.57, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1, Power Factor Greater Than 0.95 |
LUTRON EHDT832MU210 |
18C851 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 1, Lamp Type T8, Lamp Length 48 In., Voltage 120-277, Height 1 In., Width 1-5/32 In., Length 14-1/8 In., Input Watts 40.8/40.8/41.6Number of F32T8 Lamps 1, Number of F32T8U Lamps 1Amps AC 0.15/0.17/0.34, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1.17, Power Factor Greater Than 0.95 |
LUTRON EHDT832MU117 |
18C852 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 2, Lamp Type T8, Lamp Length 48 In., Voltage 120-277, Height 1 In., Width 1-5/32 In., Length 14-1/8 In., Input Watts 76.8/77.6/78Number of F32T8 Lamps 2, Number of F32T8U Lamps 2Amps AC 0.28/0.32/0.65, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1.17, Power Factor Greater Than 0.95 |
LUTRON EHDT832MU217 |
18C853 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 3, Lamp Type T8, Lamp Length 48 In., Voltage 120/220 to 240/277, Height 1 In., Width 2-3/8 In., Length 9-1/2 In., Input Watts 96/99.6/102.5Number of F32T8 Lamps 3, Number of F32T8U Lamps 3Amps AC 0.37/0.40/0.83, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1, Power Factor Greater Than 0.95 |
LUTRON EHDT832GU310 |
18C854 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 3, Lamp Type T8, Lamp Length 48 In., Voltage 120/220 to 240/277, Height 1 In., Width 2-3/8 In., Length 9-1/2 In., Input Watts 112.8/113.6/114Number of F32T8 Lamps 3, Number of F32T8U Lamps 3Amps AC 0.41/0.47/0.95, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1.17, Power Factor Greater Than 0.95 |
LUTRON EHDT832GU317 |
18C855 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 1, Lamp Type T8, Lamp Length 36 In., Voltage 120-277, Height 1 In., Width 1-5/32 In., Length 14-1/8 In., Input Watts 26.4/30.5/31.2Number of F25T8 Lamps 1Amps AC 0.11/0.11/0.26, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1, Power Factor Greater Than 0.95, Total Harmonic Distortion Less Than 10 Percent |
LUTRON EHDT825MU110 |
18C856 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 2, Lamp Type T8, Lamp Length 36 In., Voltage 120-277, Height 1 In., Width 1-5/32 In., Length 14-1/8 In., Input Watts 55.2/55.4/56.4Number of F25T8 Lamps 2Amps AC 0.20/0.23/0.47, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1, Power Factor Greater Than 0.95, Total Harmonic Distortion Less Than 10 Percent |
LUTRON EHDT825MU210 |
18C857 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 1, Lamp Type T8, Lamp Length 24 In., Voltage 120-277, Height 1 In., Width 1-5/32 In., Length 14-1/8 In., Input Watts 21.6/21.6/22.2, Number of F17T8 Lamps 1Amps AC 0.08/0.09/0.18, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1, Power Factor Greater Than 0.95, Total Harmonic Distortion Less Than 10 Percent |
LUTRON EHDT817MU110 |
18C858 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 2, Lamp Type T8, Lamp Length 24 In., Voltage 120-277, Height 1 In., Width 1-5/32 In., Length 14-1/8 In., Input Watts 41.6/42/43.2, Number of F17T8 Lamps 2Amps AC 0.15/0.18/0.35, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1, Power Factor Greater Than 0.95, Total Harmonic Distortion Less Than 10 Percent |
LUTRON EHDT817MU210 |
18C859 Grainger |
|
Dimming Ballast, Ballast Type Electronic Dimming, Ballast Family EcoSystem(r) H-Series, Number of Lamps 1, Lamp Type T5HO, Lamp Length 45-3/16 In., Voltage 120-277, Height 1 In., Width 1-5/32 In., Length 14-1/8 In., Input Watts 62.4/63.7/64.8Amps AC 0.23/0.26/0.54, Start Type Programmed Rapid, Min. Starting Temp. 50 Degrees F, Dimming Range 100 Percent to 0.7 Percent Measured RLO, Ballast Factor 1, Power Factor Greater Than 0.95, Total Harmonic Distortion Less Than 10 Percent |
LUTRON EHDT554MU110 |