Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
5KPX1 Grainger |
|
Fan Blower Control, OEM Replacement, Input Voltage 24/120 VAC, 24 Control Volts, For Use With Residential, Commercial HVAC Equipment, Replaces Carrier Control Center Part Numbers: HH84AA021, HH84AA001, HH84AA003, HH84AA005, HH84AA009, HH84AA014, HH84AA015, or CESO110019. |
ICM ICM275 |
5KPX2 Grainger |
|
Furnace Control Module, OEM Replacement, 24 Control Volts, For Use With Residential, Commercial HVAC Equipment, Replaces Goodman/Janitrol: B18099-06, B18099-08, B18099-10, B18099-13, B18099-13S, UTEC: 1012-933D, Texas Instruments: 41F-5, White-Rodgers: 50T35-730, 50T35-743 |
ICM ICM280 |
5KPX3 Grainger |
|
Furnace Control Module, OEM Replacement, 24 Control Volts, For Use With Residential, Commercial HVAC Equipment, Replaces Carrier: CESO11005700, CESO11005701, CESO11005702 |
ICM ICM281 |
5KPX4 Grainger |
|
Furnace Control Module, OEM Replacement, 24 Control Volts, For Use With Residential, Commercial HVAC Equipment, Replaces Carrier: HK42FZ004, HK42FZ007, HK42FZ008, HK42FZ009, HK42FZ011, HK42FZ013, HK42FZ016 |
ICM ICM282A |
5KPX5 Grainger |
|
Ignition Module, Hot Surface Ignition, Electrical Connections 1/4 In Quick Connect, 24 Control Volts, Gas Type LP/NG, Prepurge Time 32 Sec., Lockout Time 4 or 7 Sec., Field Replacement Of A Wide Range Of Hot Surface Ignition Modules Manufactured By Honeywell, Robertshaw And White-Rodgers, For Use With Residential, Commercial Heating Equipment |
ICM ICM283 |
5KPX6 Grainger |
|
Ignition Module, Intermittent Pilot, Electrical Connections 1/4 In Quick Connect, 24 Control Volts, Gas Type LP/NG, Prepurge Time 0 or 30 Sec., Lockout Time 300 Sec., One Or Two Rod Intermittent Pilot Control With Continuous Retry Trial Time With Configurable Lockout Timing Of 15 Or 90 Seconds And Configurable Prepurge Of 30 seconds or no prepurge, For Use With Residential, Commercial Heating Equipment, Includes Spark Cable Adapters |
ICM ICM290A |
5KPX7 Grainger |
|
Defrost Control Board, Heat Pump, Switch Type SPST, Width 2 7/8 In., Depth 3 In., Voltage 18-30 VAC, For Use With Heat Pump |
ICM ICM300 |
5KPX8 Grainger |
|
Head Pressure Control, Hard Start Timing .1 - 5 Sec, Triac Output Amps 10, 120-600 Input Volts AC @ 60/50 Hz, Control Volts 18 to 30, Controls Head Pressure By Varying the Amount of Air Through the Condenser to Help Prevent Evaporator Freeze Up, Ambient Temp Range -40 to 75 C, Status Indicator LED |
ICM ICM333 |
5KPX9 Grainger |
|
Line Voltage Monitor, Manual or Automatic Reset, Control Volts 24-240, NC Output 10 Amps, NO Output 10 Amps, Contact Rating 10 Amps, Voltage 80-300, Single Phase, Time Delay Adj. 0-720 Sec., Temp Rating -40 To 167 F, Programmable 25-Fault Memory Storage, Monitors Voltage Unbalance, High/Low Voltage, For Use With 1 Phase Equipment, Includes LCD Display |
ICM ICM492 |
6JYL2 Grainger |
|
Plug-In Line Voltage Monitor, 3-Phase, Voltage 190-480 VAC, 50/60 Hz, Percent Volts Unbalance 2-8 User Select, Monitors Low Voltage, High Voltage, Phase Loss, Power interruptions, Phase Reversal, Unblanced Voltage, Depth 2-1/2 In., Height 4 In., Width 1-3/4 In., Application Protects 3 Phase Motors And Equipment From Voltage Faults, Includes Status LED |
ICM ICM408 |