ТЕЛ:+7 (985) 487-07-35
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Артикул
Каталог
Наименование
Описание Производитель
№ модели
5GTJ5
Grainger
Подробнее... AC Current Logger, Current Range Probe Dependent, 1 Current Channels, Current Accuracy 0.50%, True RMS, Phase Single, Power Source (2) AA Batteries, Protection Rating IP50, 100 hrs. to 45 Days Recording Capacity, Special Features BNC Connection, Sampling Rate 64 Samples per Cycle, Safety Rating CAT III 50V, Interface USB, Includes Batteries, Software, USB Interface Cable and Instructions AEMC
L101
5GTJ6
Grainger
Подробнее... AC Current Logger, Current Range Probe Dependent, 2 Current Channels, Current Accuracy 0.50%, True RMS, Phase Single, Power Source (2) AA Batteries, Protection Rating IP50, 100 hrs. to 45 Days Recording Capacity, Special Features BNC Connection, Sampling Rate 64 Samples per Cycle, Safety Rating CAT III 50V, Interface USB, Includes Batteries, Software, USB Interface Cable and Instructions AEMC
L102
5GTJ7
Grainger
Подробнее... AC Current Logger, Current Range Probe Dependent, 1 Current Channels, Current Accuracy 0.50%, True RMS, Phase Single, Power Source (2) AA Batteries, Protection Rating IP50, 100 hrs. to 45 Days Recording Capacity, Special Features Banana Plug Connection, Sampling Rate 64 Samples per Cycle, Safety Rating CAT III 50V, Interface USB, Includes Batteries, Software, USB Interface Cable and Instructions AEMC
L111
5GTJ8
Grainger
Подробнее... Process Control Logger, Current Range 4 to 20mADC, 2 Current Channels, Current Accuracy 0.50%, Phase Single, Power Source (2) AA Batteries, Protection Rating IP50, 100 hrs. to 45 Days Recording Capacity, Sampling Rate 8 Samples per Storage Interval, Safety Rating CAT III 50V, Interface USB, Includes Batteries, Software, USB Interface Cable and Instructions AEMC
L322
5GTJ9
Grainger
Подробнее... DC Voltage Logger, Voltage Range -10 to 10VDC, Voltage Accuracy 0.50%, 2 Voltage Channels, Current Accuracy 0.50%, Phase Single, Power Source (2) AA Batteries, Protection Rating IP50, 100 hrs. to 45 Days Recording Capacity, Sampling Rate 8 Samples per Storage Interval, Safety Rating CAT III 50V, Interface USB, Includes Batteries, Software, USB Interface Cable and Instructions AEMC
L432
5GTK0
Grainger
Подробнее... Temperature Data Logger, J, K, T, N, E, R or S Thermocouple, Temp. Range (F) -346 to 3212 Depending Type Thermocouple Used, Accuracy +/-0.1 to 0.2% + 0.6 to 1 F Depending on Range and Type of Thermocouple, Battery Life 100 hrs to 45 Days, Remote Probe Order Separately, Waterproof IP50, Time Intervals 5 Seconds to 1 Day, Width 2.75 In., Depth 1.28 In., Height 4.98 In., Special Features Two External Inputs, Interface USB, Includes (2) AA Batteries, Software, USB Interface Cable and Instructions AEMC
L642
5GTK2
Grainger
Подробнее... AC Current Logger, Current Range Dual Range 0 to 100AAC or 0 to 1000AAC, 2 Current Channels, Current Accuracy 0.50%, Phase Single, Power Source (2) AA Batteries, Protection Rating IP50, 100 hrs. to 45 Days Recording Capacity, Sampling Rate 64 Samples per Cycle, Safety Rating CAT III 600V, CAT IV 300V, Interface USB, Includes (2) Integral Flexible Current Probes, Batteries, Software, USB Interface Cable and Instructions AEMC
ML912
5GTK3
Grainger
Подробнее... Phase Sequence Tester, Voltage Range 40 to 850VAC, Frequency Range 15 to 400Hz, Display LCD, Safety Rating CAT III 600VPhase Rotation Yes, Phase Voltage Present Indicator Yes, Includes Carrying Case, (3) 4 Ft.Test Leads, (3) Alligator Clips and User Manual, Manufacturers Warranty Length 1 Year AEMC
6608
5GTK4
Grainger
Подробнее... Event Logger, Voltage Range 0 to 3VDC Logic Level, 0 to 5VDC Logic Level or Contact Closure, 4 Voltage Channels, Power Source (2) AA Batteries, Protection Rating IP50, 100 hrs. to 45 Days Recording Capacity, Sampling Rate 8 Samples per Storage Interval, Safety Rating CAT III 50V, Interface USB, Includes Batteries, Software, USB Interface Cable and Instructions AEMC
L404
6KG56
Grainger
Подробнее... Battery Operated Megohmmeter, Output Test Voltage 250/500/1000VDC, Insulation Resistance Range 50K to 2000M Ohms, Live Circuit Detection 0 to 600VAC/DC, Resistance Range 0 to 400k OhmsDisplay Multiline LCD, Accuracy +/-3 Percent of Reading +/-1 DigitPower Source (6) AA Batteries, Includes Test Leads, Test Probe, Alligator Clips, Remote Test Probe, Batteries, Soft Carrying Case and Instructions AEMC
1045