Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
1TUE6 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 3/4 HP, 1725 Nameplate RPM, 56 NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 230/460, Full Load Amps 3.0/1.5, Phase 3, 60/50 Hz, Base Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 13-61/64 In., Lead Length 6 In. |
MARATHON MOTORS 56T17G15551 |
1TUE7 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1 HP, 1725 Nameplate RPM, 56H NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 3.4-3.6/1.8, Phase 3, 60 Hz, Base Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 13-9/16 In., Lead Length 6 In. |
MARATHON MOTORS 56T17G15552 |
1TUE8 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1-1/2 HP, 1725 Nameplate RPM, 56H NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 208-230/460, Full Load Amps 4.8-4.8/2.4, Phase 3, 60 Hz, Base Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.15, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 14-3/32 In., Lead Length 6 In. |
MARATHON MOTORS 56T17G15540 |
1TUE9 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Nonventilated, 1/3 HP, 1725 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 230/460, Full Load Amps 1.2/0.6, Phase 3, 60/50 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 10-7/8 In., Lead Length 6 In. |
MARATHON MOTORS 56T17E15515 |
1TUG1 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1/2 HP, 1725 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 230/460, Full Load Amps 2.4/1.2, Phase 3, 60/50 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 13-61/64 In., Lead Length 6 In. |
MARATHON MOTORS 56T17G15536 |
1TUG2 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 3/4 HP, 1725 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 230/460, Full Load Amps 3.0/1.5, Phase 3, 60/50 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 13-61/64 In., Lead Length 6 In. |
MARATHON MOTORS 56T17G15537 |
1TUG3 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1 HP, 1725 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 230/460, Full Load Amps 3.6/1.8, Phase 3, 60 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 13-3/4 In., Lead Length 6 In. |
MARATHON MOTORS 56T17G15542 |
1TUG4 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1-1/2 HP, 1725 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 230/460, Full Load Amps 4.8/2.4, Phase 3, 60 Hz, Face Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 14-1/4 In., Lead Length 6 In. |
MARATHON MOTORS 56T17G15543 |
1TUG6 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Nonventilated, 1/3 HP, 1725 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 230/460, Full Load Amps 1.2/0.6, Phase 3, 60/50 Hz, Face/Base Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 11-7/8 In., Lead Length 6 In. |
MARATHON MOTORS 56T17E15514 |
1TUG7 Grainger |
|
Hazardous Location Motor, 3-Phase, Totally Enclosed Fan-Cooled, 1/2 HP, 1725 Nameplate RPM, 56C NEMA/IEC Frame, NEMA Design B, CW/CCW Rotation, Voltage 230/460, Full Load Amps 2.4/1.2, Phase 3, 60/50 Hz, Face/Base Mounting, Ball Bearings, Frame Material Rolled Steel, Thermal Protection Auto, Service Factor 1.0, Hazardous Location Class 1 C, D / 2 E, F, G, Max. Ambient Temp. 40 Degrees C, Temp. Code T3B, Shaft Dia. 5/8 In., Shaft Length 1-7/8 In., Overall Length 13-3/4 In., Lead Length 6 In. |
MARATHON MOTORS 56T17G15559 |