7HY61 7HY61
DAYTON
Exh Vent, Hzd Loc, 18-1/2 In, 115/208-230 V
Exhaust Ventilator, Wheel Dia. 18-1/2 In., CFM @ 0.000-In. SP 3098, @ 0.125-In. SP 2916, Sones @ 0.125-In. SP @ 5 Ft. 10.4, Max. Inlet Temp. 300 Deg. F, Voltage 115/208-230, 60 Hz, 1 Phase, Roof Mounting Location, Base Width 30 In., Base Length 30 In., Requires Roof Curb for New Installations, Includes Hazardous Location Motor that meets Class I, Groups C & D AND Class II, Groups E, F & G
Артикул:
7HY62
Каталог:
Grainger
Производитель:
DAYTON
Номер модели:
7HY62
Страна производства:
Not Available
Вес (кг):
61.36

Спецификация:
Item: Centrifugal Upblast Exhaust Ventilator |
Type: Hazardous Location |
Style: Unassembled With Drive Package |
Wheel Dia. (In.): 18-1/2 |
Wheel Type: Backward Incline |
CFM @ 0.000-In. SP: 3098 |
CFM @ 0.125-In. SP: 2916 |
CFM @ 0.250-In. SP: 2759 |
CFM @ 0.375-In. SP: 2525 |
CFM @ 0.500-In. SP: 2257 |
CFM @ 0.675-In. SP: 1867 |
Sones @ 0.125-In. SP @ 5 Ft.: 10.4 |
Sones @ 0.250-In. SP @ 5 Ft.: 10.0 |
Sones @ 0.500-In. SP @ 5 Ft.: 9.0 |
Max. Inlet Temp. (Deg. F): 300 |
Motor Voltage: 115/208-230 |
Motor Hz: 60 |
Phase: 1 |
Max. Operating Amps: 6.6/3.1-3.3 |
Bearing Type: Sealed Pillow Block |
Motor HP: 1/3 |
Max. BHP: 0.35 |
RPM: 820 |
Speed Controllable: No |
Mounting Location: Roof |
Base Width (In.): 30 |
Base Length (In.): 30 |
Base Height (In.): 1-3/4 |
Overall Height (In.): 36-1/2 |
Overall Dia. (In.): 35-3/8 |
Shaft Dia. Wheel End (In.): 3/4 |
Shaft Dia. Sheave End (In.): 3/4 |
Housing Material: Spun Aluminum |
Wheel Material: Aluminum |
Agency Compliance: AMCA Sound & Air |
Requires: Roof Curb for New Installations |
Includes: Hazardous Location Motor that meets Class I, Groups C & D AND Class II, Groups E, F & G |
Adj. 12 3/8"H Roof Curb Stock No.: 2ZV83 |
Adj. 6 3/8"H Roof Curb Stock No.: 4C454 |
Recommended 12 In. Fixed Curb Item No.: 2RB79 |
Recommended 8 In. Fixed Curb Item No.: 4HX41 |
Recommended Damper Size (In.): 23 x 23 |
Recommended Damper Stock No.: 4HX67 |
Альтернативная продукция:
Exhaust Ventilator, Wheel Dia. 18-1/2 In., CFM @ 0.000-In. SP 2815, @ 0.125-In. SP 2617, Sones @ 0.125-In. SP @ 5 Ft. 8.6, Max. Inlet Temp. 300 Deg. F, Voltage 115/208-230, 60 Hz, 1 Phase, Roof Mounting Location, Base Width 30 In., Base Length 30 In., Requires Roof Curb for New Installations, Includes Hazardous Location Motor that meets Class I, Groups C & D AND Class II, Groups E, F & G
Exhaust Ventilator, Wheel Dia. 18-1/2 In., CFM @ 0.000-In. SP 3551, @ 0.125-In. SP 3389, Sones @ 0.125-In. SP @ 5 Ft. 13.5, Max. Inlet Temp. 300 Deg. F, Voltage 115/208-230, 60 Hz, 1 Phase, Roof Mounting Location, Base Width 30 In., Base Length 30 In., Requires Roof Curb for New Installations, Includes Hazardous Location Motor that meets Class I, Groups C & D AND Class II, Groups E, F & G
Exhaust Ventilator, Wheel Dia. 18-1/2 In., CFM @ 0.000-In. SP 4061, @ 0.125-In. SP 3919, Sones @ 0.125-In. SP @ 5 Ft. 16.2, Max. Inlet Temp. 300 Deg. F, Voltage 115/208-230, 60 Hz, 1 Phase, Roof Mounting Location, Base Width 30 In., Base Length 30 In., Requires Roof Curb for New Installations, Includes Hazardous Location Motor that meets Class I, Groups C & D AND Class II, Groups E, F & G
Exhaust Ventilator, Wheel Dia. 18-1/2 In., CFM @ 0.000-In. SP 4477, @ 0.125-In. SP 4348, Sones @ 0.125-In. SP @ 5 Ft. 17.9, Max. Inlet Temp. 300 Deg. F, Voltage 115/208-230, 60 Hz, 1 Phase, Roof Mounting Location, Base Width 30 In., Base Length 30 In., Requires Roof Curb for New Installations, Includes Hazardous Location Motor that meets Class I, Groups C & D AND Class II, Groups E, F & G