Exhaust Vent, 24 1/2 In

Exhaust Ventilator, Centrifugal Downblast With Drive Package, CFM @ 0.000-In SP 6060, @ 0.250-In SP 5449, Sones @ 0.250-In SP 11.8, Roof Mounting Location, Base Width 34 In, Base Length 34 In, Overall Height 40 1/8 In., Max. Inlet Temp. 180 Deg. F, Motor Voltage 115/230, 1 Phase, Motor 3/4 HP, 660 RPM, Wheel Dia 24 1/2 In, Application General Clean Air, Includes NEMA 1 Junction Box
Артикул:
7A575
Каталог:
Grainger
Производитель:
DAYTON
Номер модели:
7A575
Страна производства:
USA
Вес (кг):
71.92
7A575 Exhaust Vent, 24 1/2 In
Спецификация:
Item: Centrifugal Downblast Exhaust Ventilator
Type: Standard Duty
Style: Unassembled With Drive Package
Wheel Dia. (In.): 24-1/2
Wheel Type: Backward Incline
CFM @ 0.000-In. SP: 6060
CFM @ 0.125-In. SP: 5757
CFM @ 0.250-In. SP: 5449
CFM @ 0.375-In. SP: 5094
CFM @ 0.500-In. SP: 4636
CFM @ 0.675-In. SP: 4073
CFM @ 0.750-In. SP: 3217
CFM Range: 4223 to 8355 @0.0" SP
Sones @ 0.125-In. SP @ 5 Ft.: 12.4
Sones @ 0.250-In. SP @ 5 Ft.: 11.8
Max. Inlet Temp. (Deg. F): 180
Motor Voltage: 115/230
Motor Hz: 60
Phase: 1
Bearing Type: Sealed Pillow Block
Motor HP: 3/4
Max. BHP: 0.79
RPM: 660
RPM Range: 460 to 910
Speed Controllable: No
Mounting Location: Roof
Base Width (In.): 34
Base Length (In.): 34
Base Height (In.): 1 3/4
Overall Height (In.): 40 1/8
Overall Dia. (In.): 42 3/4
Shaft Dia. Wheel End (In.): 1
Shaft Dia. Sheave End (In.): 1
Housing Material: Spun Aluminum
Wheel Material: Aluminum
Agency Compliance: UL/cUL 705
Requires: Roof Curb For New Installations
Includes: NEMA 1 Junction Box
Adj. 12 3/8"H Roof Curb Stock No.: 3C438
Adj. 6 3/8"H Roof Curb Stock No.: 4c455
Recommended 12 In. Fixed Curb Item No.: 4HX50
Recommended 8 In. Fixed Curb Item No.: 4HX42
Recommended Damper Size (In.): 27 x 27
Recommended Damper Stock No.: 4HX68

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
2RB80
Grainger
Подробнее... Roof Curb, Fixed, Nonventilated, Curb Height 12 In, Curb Square O D 32 1/2 In, Curb Square I D 29 1/2 In, 18 Gauge Galvanized Steel Construction, Use w/Dayton Ventilators Having a 34 In Square Base, For Use With Flat Roofs Only, Includes Damper Tray DAYTON
2RB80
4HX68
Grainger
Подробнее... Backdraft Damper, Roof Mount, Exhaust, Damper Size 27 x 27 In, Overall Size 29 x 29 In, Flange Width 1 In, Max Velocity 2250 FPM, Construction Material G-90 Galvanized Steel Frame, Aluminum Blades, Stainless Steel Pivot Pins, Nylon Bushings and Galvanized Steel Tie Rods., Includes Pre-punched Conduit Hole Knock-out and Felted Edges For Quiet Operation DAYTON
4HX68
4PU53
Grainger
Подробнее... Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 125/52 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU53
4PU54
Grainger
Подробнее... Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 165/74 F/C, Temp Differential 25 F, Full Load Amps @120V 9.8, @240V 4.9, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU54
4PU55
Grainger
Подробнее... Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 200/93 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU55
Альтернативная продукция:
7A574  7A574
DAYTON
Exhaust Ventilator, Centrifugal Downblast With Drive Package, CFM @ 0.000-In SP 5371, @ 0.250-In SP 4666, Sones @ 0.250-In SP 9.1, Roof Mounting Location, Base Width 34 In, Base Length 34 In, Overall Height 40 1/8 In., Max. Inlet Temp. 180 Deg. F, Motor Voltage 115/230, 1 Phase, Motor 1/2 HP, 585 RPM, Wheel Dia 24 1/2 In, Application General Clean Air, Includes NEMA 1 Junction Box

7A576  7A576
DAYTON
Exhaust Ventilator, Centrifugal Downblast With Drive Package, CFM @ 0.000-In SP 6702, @ 0.250-In SP 6158, Sones @ 0.250-In SP 14.3, Roof Mounting Location, Base Width 34 In, Base Length 34 In, Overall Height 40 1/8 In., Max. Inlet Temp. 180 Deg. F, Motor Voltage 115/230, 1 Phase, Motor 1 HP, 730 RPM, Wheel Dia 24 1/2 In, Application General Clean Air, Includes NEMA 1 Junction Box

7A639  7A639
DAYTON
Exhaust Ventilator, Centrifugal Upblast With Drive Package, CFM @ 0.000-In SP 6074, @ 0.250-In SP 5461, 12.8 Sones @ 0.250-In SP, Roof Mounting Location, Base Width 34 In, Base Length 34 In, Overall Height 41 1/4 In, Max. Inlet Temp. 300 Deg. F, Motor Voltage 115/230, 1 Phase, Motor 3/4 HP, 670 RPM, Wheel Dia 24 1/2 In, Application General/Kitchen, Includes NEMA 1 Junction Box