Circuit Breaker, D Curve, 3 Pole, 50A

Miniature Multi9 Circuit Breaker, Current Rating 50 Amps, Number of Poles 3, Maximum Voltage 480 Volts, High Tripping Current 700 Amps, Low Current Trip Setting 500 Amps, DIN Mounted
Артикул:
6B142
Каталог:
Grainger
Производитель:
SCHNEIDER ELECTRIC
Номер модели:
MG24545
Страна производства:
France
Вес (кг):
0.39
6B142 Circuit Breaker, D Curve, 3 Pole, 50A
Спецификация:
Item: Circuit Protector
Type: Din Rail Mount
Circuit Breaker Type: Miniature UL 1077
Curve Type: D
Number of Poles: 3
Amps: 50
Voltage: 480Y/277 VAC
AIR Rating: 5k
AIR @ 120VAC: 10k
AIR @ 125VDC: 10k
AIR @ 240VAC: 10k
AIR @ 277VAC: 5k
AIR @ 480VAC: 5k
AIR @ 48VDC: 10k
AIR @ 65VDC: 10k
Phase: 3
Terminal Connection: Lug
Min. Wire Size (AWG): 14
Max. Wire Size (AWG): 2
Length (In.): 3.19
Width (In.): 2.13
Depth (In.): 3.00
Instantaneous Trip: Fixed
High Amp Trip Setting: 700
Low Amp Trip Setting: 500
Frame Size: 63A/C100N
Standards: UL 1077, CE, CSA
Альтернативная продукция:
10K623  EP63ULD50
GENERAL ELECTRIC
Circuit Breaker, Din Rail Mount, Miniature UL 1077 Circuit Breaker Type, Toggle Switch Type, D Curve Type, Number of Poles 3, 50 Amps, 480VAC, Max. DC Voltage (V) 110, AIR Rating 6kA, 6kA, 6kA, 6kA, 6kA, 6kA, 6kA, 6kA, 3 Phase, Any Phase Connection, Screw Clamp Terminal Connection, Min. Wire Size (AWG) 14, Max. Wire Size (AWG) 4, Length (In.) 4.625, Width (In.) 2.81, Depth (In.) 2.062, Fixed Instantaneous Trip, High Amp Trip Setting 700, Low Amp Trip Setting 700, Standards UL, CSA, DIN

10K729  EP103ULD50
GENERAL ELECTRIC
Circuit Breaker, Din Rail Mount, Miniature UL 1077 Circuit Breaker Type, Toggle Switch Type, D Curve Type, Number of Poles 3, 50 Amps, 480VAC, Max. DC Voltage (V) 110, AIR Rating 10kA, 10kA, 10kA, 10kA, 10kA, 10kA, 10kA, 10kA, 3 Phase, Any Phase Connection, Screw Clamp Terminal Connection, Min. Wire Size (AWG) 14, Max. Wire Size (AWG) 4, Length (In.) 4.625, Width (In.) 2.81, Depth (In.) 2.062, Fixed Instantaneous Trip, High Amp Trip Setting 700, Low Amp Trip Setting 700, Standards UL, CSA, DIN

5ZVG4  5ZVG4
DAYTON
Miniature Circuit Breaker, DIN Rail Mounted, High Interrupting Capacity Circuit Breaker Type, Lever Switch Type, D Curve Type, Number of Poles 3, 50 Amps, 480, Max. DC Voltage (V) N/A, AIR Rating 7.5kA@480VAC, 3 Phase, Screw Clamp Terminal Connection, Min. Wire Size (AWG) 14, Max. Wire Size (AWG) 2, Length (In.) 3.21, Width (In.) 2.13, Depth (In.) 2.91, Fixed Instantaneous Trip, Frame Size 63, Standards UL, CSA, TUV, CE