ТЕЛ:+7 (985) 487-07-35
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Circuit Breaker, D Curve, 1 Pole, 6A

Miniature Multi9 Circuit Breaker, Current Rating 6 Amps, Number of Poles 1, Maximum Voltage 277 Volts, High Tripping Current 84 Amps, Low Current Trip Setting 60 Amps, DIN Mounted
Артикул:
6B107
Каталог:
Grainger
Производитель:
SCHNEIDER ELECTRIC
Номер модели:
MG24504
Страна производства:
France
Вес (кг):
0.11
6B107 Circuit Breaker, D Curve, 1 Pole, 6A
Спецификация:
Item: Circuit Protector
Type: Din Rail Mount
Circuit Breaker Type: Miniature UL 1077
Curve Type: D
Number of Poles: 1
Amps: 6
Voltage: 277VAC
Max. DC Voltage (V): 65
AIR Rating: 5k
AIR @ 120VAC: 10k
AIR @ 125VDC: 10k
AIR @ 240VAC: 10k
AIR @ 277VAC: 5k
AIR @ 480VAC: 5k
AIR @ 48VDC: 10k
AIR @ 65VDC: 10k
Phase: 1
Terminal Connection: Screw Clamp
Min. Wire Size (AWG): 14
Max. Wire Size (AWG): 4
Length (In.): 3.19
Width (In.): 0.71
Depth (In.): 3.00
Instantaneous Trip: Fixed
High Amp Trip Setting: 84
Low Amp Trip Setting: 60
Frame Size: 63A/C100N
Standards: UL 1077, CE, CSA
Альтернативная продукция:
10K589  EP61ULD06
GENERAL ELECTRIC
Circuit Breaker, Din Rail Mount, Miniature UL 1077 Circuit Breaker Type, Toggle Switch Type, D Curve Type, Number of Poles 1, 6 Amps, 277VAC, Max. DC Voltage (V) 50, AIR Rating 6kA, 6kA, 6kA, 6kA, 6kA, 6kA, 6kA, 6kA, 1 Phase, Any Phase Connection, Screw Clamp Terminal Connection, Min. Wire Size (AWG) 14, Max. Wire Size (AWG) 4, Length (In.) 4.625, Width (In.) 2.81, Depth (In.) 0.687, Fixed Instantaneous Trip, High Amp Trip Setting 84, Low Amp Trip Setting 84, Standards UL, CSA, DIN

10K695  EP101ULD06
GENERAL ELECTRIC
Circuit Breaker, Din Rail Mount, Miniature UL 1077 Circuit Breaker Type, Toggle Switch Type, D Curve Type, Number of Poles 1, 6 Amps, 277VAC, Max. DC Voltage (V) 50, AIR Rating 10kA, 10kA, 10kA, 10kA, 10kA, 10kA, 10kA, 10kA, 1 Phase, Any Phase Connection, Screw Clamp Terminal Connection, Min. Wire Size (AWG) 14, Max. Wire Size (AWG) 4, Length (In.) 4.625, Width (In.) 2.81, Depth (In.) 0.687, Fixed Instantaneous Trip, High Amp Trip Setting 84, Low Amp Trip Setting 84, Standards UL, CSA, DIN

5ZVD6  5ZVD6
DAYTON
Miniature Circuit Breaker, DIN Rail Mounted, High Interrupting Capacity Circuit Breaker Type, Lever Switch Type, D Curve Type, Number of Poles 1, 6 Amps, 277, Max. DC Voltage (V) N/A, AIR Rating 7.5kA@240V, 5kA@277V, 1 Phase, Screw Clamp Terminal Connection, Min. Wire Size (AWG) 14, Max. Wire Size (AWG) 4, Length (In.) 3.21, Width (In.) 0.71, Depth (In.) 2.91, Fixed Instantaneous Trip, High Amp Trip Setting 86.4, Low Amp Trip Setting 57.6, Frame Size 63, Standards UL, CSA, TUV, CE