5XHH5 ECX09H1CAA-R63/D
EATON
Mtr Starter, 480VAC, 9-45A, Start/Stop
Number of Poles 3, 32 Amps AC, Aux. Contact Configuration NO, Coil Volts 480VAC, 2 HP @ 1 Phase - 120V, 5 HP @ 1 Phase - 230V, 10 HP @ 3 Phase - 208V, 10 HP @ 3 Phase - 230V, 20 HP @ 3 Phase - 460V, 30 HP @ 3 Phase - 575V, Motor Starter, Non-Reversing, 50/60 Hz, NEMA Enclosure Type 1, IEC, Standards UL 508, Includes Start/Stop Push Button
Артикул:
5XHH6
Каталог:
Grainger
Производитель:
EATON
Номер модели:
ECX09H1CBA-R63/D
Страна производства:
USA
Вес (кг):
4.80

Спецификация:
Item: Motor Starter |
Type: Non-Reversing |
Starter Type: IEC |
Coil Volts: 480VAC |
Hz: 50/60 |
Number of Poles: 3 |
Amps AC: 32 |
Overload Relay Amp Setting: 9-45A |
HP @ 1 Phase - 120V: 2 |
HP @ 1 Phase - 230V: 5 |
HP @ 3 Phase - 208V: 10 |
HP @ 3 Phase - 230V: 10 |
HP @ 3 Phase - 460V: 20 |
HP @ 3 Phase - 575V: 30 |
Height (In.): 8.5 |
Width (In.): 14.9 |
Depth (In.): 10.1 |
Aux. Contact Configuration: NO |
NEMA Enclosure Type: 1 |
Standards: UL 508 |
Includes: Start/Stop Push Button |
Дополнительные аксессуары: | ||||
Артикул Каталог |
Наименование |
Описание | Производитель № модели |
|
---|---|---|---|---|
4TYZ7 Grainger |
Contactor, IEC, Full Load Amps-Inductive 32, Full Load Amps-Resistive 45, Number of Poles 3, Coil Volts 480VAC, 50/60 Hz, Non Reversing, Enclosure Type Open, Auxiliary Contact Form 1NO, 5 HP @ 1 Phase - 120V, 10 HP @ 1 Phase - 230V, 10 HP @ 3 Phase - 208V, 20 HP @ 3 Phase - 230V, 25 HP @ 3 Phase - 480V, 30 HP @ 3 Phase - 575V, Height 3.35", Width 1.77'', Depth 3.82", Series Frame C, Standards UL/CE/CSA/CCC/ATEX/IEC EN 60947 | EATON XTCE032C10C |
||
5XHL3 Grainger |
Overload Relay, Electronic, Depth (In.) 4.500, Height (In.) 3.500, Width (In.) 2.250, Standards UL, CSA, IEC | EATON XTOE045CCS |
Альтернативная продукция:
Number of Poles 3, 32 Amps AC, Aux. Contact Configuration NO, Coil Volts 480VAC, 2 HP @ 1 Phase - 120V, 5 HP @ 1 Phase - 230V, 10 HP @ 3 Phase - 208V, 10 HP @ 3 Phase - 230V, 20 HP @ 3 Phase - 460V, 30 HP @ 3 Phase - 575V, Motor Starter, Non-Reversing, 50/60 Hz, NEMA Enclosure Type 1, IEC, Standards UL 508
Number of Poles 3, 32 Amps AC, Aux. Contact Configuration NO, Coil Volts 480VAC, 2 HP @ 1 Phase - 120V, 5 HP @ 1 Phase - 230V, 10 HP @ 3 Phase - 208V, 10 HP @ 3 Phase - 230V, 20 HP @ 3 Phase - 460V, 30 HP @ 3 Phase - 575V, Motor Starter, Non-Reversing, 50/60 Hz, NEMA Enclosure Type 1, IEC, Standards UL 508, Includes Start/Stop Push Button and Red Run Pilot Light
Number of Poles 3, 32 Amps AC, Aux. Contact Configuration NO, Coil Volts 480VAC, 2 HP @ 1 Phase - 120V, 5 HP @ 1 Phase - 230V, 10 HP @ 3 Phase - 208V, 10 HP @ 3 Phase - 230V, 20 HP @ 3 Phase - 460V, 30 HP @ 3 Phase - 575V, Motor Starter, Non-Reversing, 50/60 Hz, NEMA Enclosure Type 1, IEC, Standards UL 508, Includes Hand/Off/Auto Selector Switch
Number of Poles 3, 32 Amps AC, Aux. Contact Configuration NO, Coil Volts 480VAC, 2 HP @ 1 Phase - 120V, 5 HP @ 1 Phase - 230V, 10 HP @ 3 Phase - 208V, 10 HP @ 3 Phase - 230V, 20 HP @ 3 Phase - 460V, 30 HP @ 3 Phase - 575V, Motor Starter, Non-Reversing, 50/60 Hz, NEMA Enclosure Type 1, IEC, Standards UL 508, Includes Hand/Off/Auto Selector Switch and Red Run Pilot Light