ТЕЛ:+7 (985) 487-07-35
WhatsApp / Telegram: +7 (916) 211-71-00
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

AC Drive, 1 HP

AC Drive, Motor Power Rating 1 HP, Output Current 5.0 Amps, Height 10.3 Inches, Width 4.3 Inches, Depth 5.7 Inches, 200 to 230 VAC, 50/60 hz, NEMA 4, Three Phase Input
Артикул:
5HV37
Каталог:
Grainger
Производитель:
FUJI
Номер модели:
FRN001G11W-2UX
Страна производства:
Not Available
Вес (кг):
3.32
5HV37 AC Drive, 1 HP
Спецификация:
Item: AC Drive
Drive Type: Adjustable Frequency Variable Torque
Max. HP: 1
Max. Output Amps: 5.0
Voltage: 200-240
Voltage Output: 200-240
Input Phase AC: 3
Output Phase AC: 3
Enclosure: NEMA 4
Height (In.): 10.3
Width (In.): 4.3
Depth (In.): 5.70
Functions: Operating Method/Frequency Setting, Base and Top Frequency, Maximum Output Frequency, Torque Boost, Fault Memory, DC Braking, Acceleration/Deceleration, Motor Sound Adjustment, Maximum Output Voltage, Slip Compensation, Torque Limit Control, Sensorless Torque Vector, Jump Frequency, Automatic Deceleration Time, Automatic Pattern Operation
Protection: Overcurrent, Overvoltage, Undervoltage, Inverter Heatsink and Brake Resistor Overheating
Displays: Input Volts, Output Amps, RPM, Frequency or Conveyor Speed

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
4XJL3
Grainger
Подробнее... Output Filter, dV/dT, Voltage 600V & Below, Amps 6, HP 3, Phase Three, Enclosure Type UL Type 1, Watts Loss 80, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is 100 Ft. to 1000 Ft., Height 9 In., Width 5.5 In., Depth 10 In., Standards UL Listed, CE certified V1K FILTERS
V1K6A01
4XJR1
Grainger
Подробнее... Input Line Reactor, Low Z, Voltage 208/240, Amps 4.6, 1 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 11, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA25LE01
4XRK9
Grainger
Подробнее... Input Line Reactor, Low Z, Voltage 208/240, Amps 4.6, HP 1, Phase Three, Enclosure Type Open, Watts Loss 11, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 4 In., Width 4.18 In., Depth 3.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA25L
4XRP3
Grainger
Подробнее... Input Line Reactor, High Z, Voltage 208/240, Amps 4.6, HP 1, Phase Three, Enclosure Type Open, Watts Loss 23.6, Impedance 5%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 4 In., Width 4.18 In., Depth 3.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA25H
Обратите внимание:
13E652
AC Drive, 3 HP, NEMA 4X, 9.0A, 230V 3 Ph
14H080
Enclosed Drive w/By-pass, Amps 11
33M544
460V, 3-Phase, 700HP, 840A, FRENIC-ECO
4LRK6
AC Drive, Var.Freq., 20HP, 27A, 480VAC