1H514 8536SCO3V03
SQUARE D
Motor Starter, NEMA Sz1, 240V, Solid State
Magnetic Motor Starter, Non Reversing, NEMA Size 1, Maximum Current 27 Amps, Number of Poles 3, Coil Voltage 240 VAC, Power Rating @ 230 VAC Three Phase 7.5 HP, Power Rating @ 460 VAC Three Phase 10 HP, Height 4.45 Inches, Length 6.90 Inches, Width 3.50 Inches, Open Type, Solid State Overload Relay
Артикул:
5F037
Каталог:
Grainger
Производитель:
SQUARE D
Номер модели:
8536SCO3V03H30
Страна производства:
Mexico
Вес (кг):
1.89
Спецификация:
Type: NEMA |
Starter Type: Nonreversing |
NEMA Size: 1 |
Coil Volts: 240VAC |
Number of Poles: 3 |
Amps AC: 27 |
HP @ 3 Phase - 208V: 7-1/2 |
HP @ 3 Phase - 230V: 7-1/2 |
HP @ 3 Phase - 460V: 10 |
Height (In.): 6.90 |
Width (In.): 4.50 |
Depth (In.): 3.50 |
NEMA Enclosure Type: Open |
Includes: Solid state overload relay |
Дополнительные аксессуары: | ||||
Артикул Каталог |
Наименование |
Описание | Производитель № модели |
|
---|---|---|---|---|
1H426 Grainger |
Magnetic Coil, Starter Size 00, 0, 1, For Use With Starter Type SA Series A, SB, SC, SM, 240 VAC, For Class 8502/8536 | SQUARE D 31041-400-51 |
||
1H577 Grainger |
Circuit Fuse Holder, Starter Size All, For NEMA 00-7 Starter/Contactor, Single Fuse Unit | SQUARE D 9999SF3 |
||
1H578 Grainger |
Circuit Fuse Holder, Starter Size All, For NEMA Starter/Contactor, Two Fuse Unit | SQUARE D 9999SF4 |
||
1H589 Grainger |
Auxiliary Contact, Starter Size 00-2, For Use With Starter Type SA, SD, M, With 1 Normally Open Contact, Internal Non Convertible | SQUARE D 9999SX11 |
||
5F585 Grainger |
Solid State Overload Relay, NEMA Size 1, Full Load Current Range 9-27 Amps, Retrofit Mounting for 8536 Motor Starter 5F594, Separate Mounting 5F595, Trip Class 20, Motor Logic | SQUARE D 9065SS120 |
Альтернативная продукция:
Magnetic Motor Starter, Non Reversing, NEMA Size 1, NEMA Type Open, Number Of Poles 3, Power Rating @ 208-230 VAC Three Phase 7.5 HP, Power Rating @ 460 VAC Three Phase 10 HP, Length 6.77 Inches, Height 4.22 Inches, Width 3.50 Inches, 240 VAC Coil, Three Thermal Units Required Sold Separately
Magnetic Motor Starter, Non Reversing, NEMA Size 2, Maximum Current 45 Amps, Number of Poles 3, Coil Voltage 240 VAC, Power Rating @ 230 VAC Three Phase 10/15 HP, Power Rating @ 460 VAC Three Phase 25 HP, Height 5.00 Inches, Length 7.85 Inches, Width 5.00 Inches, Open Type, Solid State Overload Relay
Motor Starter, NEMA, Non Reversing, NEMA Size 1, NEMA Enclosure Type Open, Coil Volts 240, 50/60 Hz, Number of Poles 3, 27 Amps AC, Aux. Contact Configuration 1NO, 2 HP @ 1 Phase - 120V, 3 HP @ 1 Phase - 230V, 7-1/2 HP @ 3 Phase - 208V, 7-1/2 HP @ 3 Phase - 230V, 10 HP @ 3 Phase - 460V, 10 HP @ 3 Phase - 575V, Height (In.) 5.00, Width (In.) 5.00, Depth (In.) 7.50, Standards UL/ CSA, Includes Class 20 Solid State Ambient-Compensated Overload Relay and Instantaneous Magnetic Trip Mechanism
Motor Starter, NEMA, Non Reversing, NEMA Size 1, NEMA Enclosure Type Open, Coil Volts 240, 50/60 Hz, Number of Poles 3, 27 Amps AC, Aux. Contact Configuration 1NO, 2 HP @ 1 Phase - 120V, 3 HP @ 1 Phase - 230V, 7-1/2 HP @ 3 Phase - 208V, 7-1/2 HP @ 3 Phase - 230V, 10 HP @ 3 Phase - 460V, 10 HP @ 3 Phase - 575V, Height (In.) 5.00, Width (In.) 5.00, Depth (In.) 7.50, Standards UL/ CSA, Includes Class 20 Solid State Ambient-Compensated Overload Relay and Instantaneous Magnetic Trip Mechanism