ТЕЛ:+7 (985) 487-07-35
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Exhaust Vent, 13 3/4 In

Centrifugal Exhaust Ventilator, Direct Drive Downblast, CFM @ 0.000-In SP 2448, @ 0.250-In SP 2338, 16.7 Sones @ 0.250-In SP, Roof Mounting Location, Base Width 22 In, Base Length 22 In, Max Inlet Temp 130 F, Motor Voltage 115/230, 1 Phase, Motor 1/2 HP, Wheel Dia 13 3/4 In, Housing Material Spun Aluminum, Speed Controllable, General Purpose Application, Includes NEMA 1 Junction Box
Артикул:
4YC71
Каталог:
Grainger
Производитель:
DAYTON
Номер модели:
4YC71
Страна производства:
USA
Вес (кг):
24.09
4YC71 Exhaust Vent, 13 3/4 In
Спецификация:
Item: Downblast Exhaust Ventilator
Number of Speeds: 1
Wheel Dia. (In.): 13-3/4
CFM @ 0.000-In. SP: 2448
CFM @ 0.125-In. SP: 2393
CFM @ 0.250-In. SP: 2338
CFM @ 0.375-In. SP: 2281
CFM @ 0.500-In. SP: 2220
CFM @ 0.625-In. SP: 2159
CFM @ 0.750-In. SP: 2089
CFM @ 0.875-In. SP: 2018
CFM @ 1.000-In. SP: 1935
CFM @ 1.250-In. SP: 1746
CFM @ 1.500-In. SP: 1474
Sones @ 0.125-In. SP @ 5 Ft.: 17.0
Sones @ 0.250-In. SP @ 5 Ft.: 16.7
Motor Voltage: 115/230
Phase: 1
Hz: 60
Max. Operating Amps: 6.0/3.0
Motor HP: 1/2
Max. BHP: 0.60
RPM: 1725
Base Width (In.): 22
Base Length (In.): 22
Base Height (In.): 1-3/4
Overall Dia. (In.): 28-3/8
Overall Height (In.): 23-3/4
Shaft Dia. Wheel End (In.): 1/2
Mounting Location: Roof
Max. Inlet Temp. (Deg. F): 130
Housing Material: Spun Aluminum
Wheel Material: Aluminum
Wheel Type: Backward Incline
Speed Control: 1DGV3
Speed Controllable: Yes
Agency Compliance: UL/cUL 705
Requires: Curb For New Installations
Includes: NEMA 1 Junction Box
Adj. 12 3/8"H Roof Curb Stock No.: 2ZV82
Adj. 6 3/8"H Roof Curb Stock No.: 4C453
Recommended 12 In. Fixed Curb Item No.: 2RB76
Recommended 8 In. Fixed Curb Item No.: 4HX39
Recommended Damper Size (In.): 15 x 15
Recommended Damper Stock No.: 4HX65

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
1H400
Grainger
Подробнее... Manual Switch, Number of Poles 2, Amps 30, Resistive Amps 30, Enclosure Size Standard, Enclosure Type NEMA 1, HP @1 Phase 115V 2, @1 Phase 230V 2, @Max HP at 90VDC 1, @115VDC 2, @230VDC 1.5, Sheet Metal Surface Mounting Enclosure, Thermoplastic Wrap Around Cover, Small Machine Tools, Pumps, Fans, Conveyors, Resistance Heaters, Height 4 1/4 In, Width 2 7/16 In, Depth 2 3/4 In SQUARE D
2510KG1
1H408
Grainger
Подробнее... Non Reversing Manual Switch, Number of Poles 2, Maximum Current Rating 30 Amps, NEMA Class 4, Enclosure Size Standard, Enclosure NEMA 4, Resisitve Current 30 Amps, Maximum Power 2 HP, Power Rating @ 115 VAC Single Phase 2 HP, Maximum Power @ 90 VDC 1 HP, Power Rating @ 115 VDC 2 HP, Power Rating @ 230 VDC 1.5 HP, Power Rating @ 230 VAC Three Phase 2 HP, Power Rating @ 460-575 VAC Three Phase 3 HP, AC Voltage 115/230 Volts, Phase Single, Length 4 1/4 Inches, Height 4 1/4 Inches, Toggle SQUARE D
2510KW1
4HX65
Grainger
Подробнее... Backdraft Damper, Roof Mount, Exhaust, Damper Size 15 x 15 In, Overall Size 17 x 17 In, Flange Width 1 In, Max Velocity 2000 FPM, Construction Material G-90 Galvanized Steel Frame, Aluminum Blades, Stainless Steel Pivot Pins, Nylon Bushings and Galvanized Steel Tie Rods., Includes Pre-punched Conduit Hole Knock-out and Felted Edges For Quiet Operation DAYTON
4HX65
4PU53
Grainger
Подробнее... Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 125/52 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU53
4PU54
Grainger
Подробнее... Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 165/74 F/C, Temp Differential 25 F, Full Load Amps @120V 9.8, @240V 4.9, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU54
Альтернативная продукция:
4YC73  4YC73
DAYTON
Centrifugal Exhaust Ventilator, Direct Drive Downblast, CFM @ 0.000-In SP 2540, @ 0.250-In SP 2145, 9.6 Sones @ 0.250-In SP, Roof Mounting Location, Base Width 26 In, Base Length 26 In, Max Inlet Temp 130 F, Motor Voltage 115, 1 Phase, Motor 1/4 HP, Wheel Dia 16 3/4 In, Housing Material Spun Aluminum, Speed Controllable, General Purpose Application, Includes NEMA 1 Junction Box

4YC90  4YC90
DAYTON
Exhaust Ventilator, Axial Direct Drive Downblast, CFM @ 0.000-In SP 2457, @ 0.125-In SP 2298, @ 0.250-In SP 2093, 16.2 Sones @ 0.250-In SP, Roof Mounting Location, Base Width 22 In, Base Length 22 In, Overall Height 18 1/4 In, Max Inlet Temp 120 F, Motor Voltage 115, 1 Phase, Max Operating Amps 4.4, Motor HP 1/2, 1140 RPM, Propeller Dia 14 In, Propeller Material Aluminum, Speed Controllable, Application General Purpose, Includes NEMA 1 Junction Box

5DVT1  5DVT1
DAYTON
Exhaust Ventilator, Centrifugal Direct Drive Downblast, Wheel Dia 13 3/4 In, CFM @ 0.000-In. SP 1618, Motor Voltage 115, 1 Phase, 60 Hz, Max Operating Amps 2.2, Motor HP 1/6, Base Width 22 In, Base Length 22 In, Mounting Location Roof, Max Inlet Temp 130 Deg F, Speed Control 1DGV1, Requires Roof Curb for New Installations, Includes NEMA 1 Junction Box

5DVT4  5DVT4
DAYTON
Downblast Exhaust Ventilator, Number of Speeds Variable, Wheel Dia. (In.) 14-3/4, CFM @ 0.000-In. SP 1948/2412/2875, Sones @ 0.125-In. SP @ 5 Ft. 9.4/13.2/18, Sones @ 0.250-In. SP @ 5 Ft. 9/12.9/17.4, Motor Voltage 115, 1 Phase, 60 Hz, Max. Operating Amps 10.1, Motor HP 3/4, Max. BHP 0.24/0.46/0.78, RPM 1050/1300/1550, Base Width (In.) 26, Base Length (In.) 26, Base Height (In.) 1-3/4, Overall Dia. (In.) 28-3/8, Overall Height (In.) 23-3/4, Shaft Dia. Wheel End (In.) 1/2, Mounting Location Roof