Roof Vent, 3 Spd, 115 V, CFM 253/314/374

Exhaust Ventilator, Centrifugal, Direct Drive Downblast, 3 Speed, Wheel Dia 8 1/4 In, CFM @ 0.000-In SP 253/314/374, @ 0.250-In SP /171/274, /2.6/4.7 Sones @ 0.250-In SP, Motor Voltage 115, 1 Phase, Motor 1/30 HP, Base Width 19 In, Base Length 19 In, Roof Mounting Location, Max Inlet Temp 130 Deg F, Housing Material Spun Aluminum, Speed Controllable, Includes NEMA 1 Junction Box
Артикул:
4YC64
Каталог:
Grainger
Производитель:
DAYTON
Номер модели:
4YC64
Страна производства:
USA
Вес (кг):
8.64
4YC64 Roof Vent, 3 Spd, 115 V, CFM 253/314/374
Спецификация:
Item: Downblast Exhaust Ventilator
Number of Speeds: 3
Wheel Dia. (In.): 8-1/4
CFM @ 0.000-In. SP: 253/314/374
CFM @ 0.125-In. SP: 179/257/327
CFM @ 0.250-In. SP: -/171/274
CFM @ 0.375-In. SP: -/-/190
Sones @ 0.125-In. SP @ 5 Ft.: 5.2/3.3/1.5
Sones @ 0.250-In. SP @ 5 Ft.: -/2.6/4.7
Motor Voltage: 115
Phase: 1
Hz: 60
Max. Operating Amps: 0.68/0.77/1
Motor HP: 1/30
Max. BHP: 0.03
RPM: 1050/1300/1550
Base Width (In.): 19
Base Length (In.): 19
Base Height (In.): 1-3/4
Overall Dia. (In.): 19-3/8
Overall Height (In.): 13-7/8
Shaft Dia. Wheel End (In.): 5/16
Mounting Location: Roof
Max. Inlet Temp. (Deg. F): 130
Housing Material: Spun Aluminum
Wheel Material: Aluminum
Wheel Type: Backward Incline
Speed Control: 1DGV1
Speed Controllable: Yes
Agency Compliance: UL/cUL 705
Requires: Roof Curb For New Installations
Includes: NEMA 1 Junction Box
Adj. 12 3/8"H Roof Curb Stock No.: 2ZV82
Adj. 6 3/8"H Roof Curb Stock No.: 4C453
Recommended 12 In. Fixed Curb Item No.: 2RB75
Recommended 8 In. Fixed Curb Item No.: 4HX38

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
1H400
Grainger
Подробнее... Manual Switch, Number of Poles 2, Amps 30, Resistive Amps 30, Enclosure Size Standard, Enclosure Type NEMA 1, HP @1 Phase 115V 2, @1 Phase 230V 2, @Max HP at 90VDC 1, @115VDC 2, @230VDC 1.5, Sheet Metal Surface Mounting Enclosure, Thermoplastic Wrap Around Cover, Small Machine Tools, Pumps, Fans, Conveyors, Resistance Heaters, Height 4 1/4 In, Width 2 7/16 In, Depth 2 3/4 In SQUARE D
2510KG1
1H408
Grainger
Подробнее... Non Reversing Manual Switch, Number of Poles 2, Maximum Current Rating 30 Amps, NEMA Class 4, Enclosure Size Standard, Enclosure NEMA 4, Resisitve Current 30 Amps, Maximum Power 2 HP, Power Rating @ 115 VAC Single Phase 2 HP, Maximum Power @ 90 VDC 1 HP, Power Rating @ 115 VDC 2 HP, Power Rating @ 230 VDC 1.5 HP, Power Rating @ 230 VAC Three Phase 2 HP, Power Rating @ 460-575 VAC Three Phase 3 HP, AC Voltage 115/230 Volts, Phase Single, Length 4 1/4 Inches, Height 4 1/4 Inches, Toggle SQUARE D
2510KW1
4PU53
Grainger
Подробнее... Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 125/52 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU53
4PU54
Grainger
Подробнее... Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 165/74 F/C, Temp Differential 25 F, Full Load Amps @120V 9.8, @240V 4.9, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU54
4PU55
Grainger
Подробнее... Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 200/93 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire DAYTON
4PU55
Альтернативная продукция:
4YC65  4YC65
DAYTON
Exhaust Ventilator, Centrifugal, Direct Drive Downblast, 3 Speed, Wheel Dia 8 1/4 In, CFM @ 0.000-In SP 297/367/438, @ 0.250-In SP /195/309, /3.5/4.9 Sones @ 0.250-In SP, Motor Voltage 115, 1 Phase, Motor 1/25 HP, Base Width 19 In, Base Length 19 In, Roof Mounting Location, Max Inlet Temp 130 Deg F, Housing Material Spun Aluminum, Speed Controllable, Includes NEMA 1 Junction Box

4YC86  4YC86
DAYTON
Exhaust Ventilator, Axial Direct Drive Downblast, CFM @ 0.000-In SP 550, @ 0.125-In SP 465, @ 0.250-In SP 347, 13.2 Sones @ 0.250-In SP, Roof Or Wall Mounting Location, Base Width 19 In, Base Length 19 In, Overall Height 17 In, Max Inlet Temp 120 F, Motor Voltage 115, 1 Phase, Max Operating Amps 0.9, Motor HP 1/8, 1750 RPM, Propeller Dia 10 In, Propeller Material Aluminum, Speed Controllable, Application General Purpose, Includes NEMA 1 Junction Box