3MPU9 PLA15XS2P
PLASTEC
Blower, D/D, Haz Loc, 115/230 V, HP 1/3
Blower, Hazardous Location, Direct Drive Forward Curve, Wheel Dia 5.9 In, CFM @ 0.250-In SP 250, CFM @ 0.500-In SP 150, 54 dBA @ 5 Feet, Max Inlet Temp 140 Deg F, Voltage 115/230, 50/60 Hz, 1 Phase, Full Load Amps 6.6/3.3, Motor HP 1/3, Height 16.13 In, Width 14.16 In, Depth 18.82 In, Inlet Dia 4.92 In, Outlet Dia 4.92 In, Housing Material Polypropylene, Includes Hazardous Location Motor for Class I Group D, Class II Groups F and G, Division 1 and Division 2
Артикул:
3MPV4
Каталог:
Grainger
Производитель:
PLASTEC
Номер модели:
PLA15XS4P
Страна производства:
USA
Вес (кг):
24.55

Спецификация:
Item: Blower |
Type: Hazardous Location, Direct Drive Forward Curve |
Wheel Dia. (In.): 5.90 |
Wheel Width (In.): 5.92 |
CFM @ 0.200-In. SP: # |
CFM @ 0.250-In. SP: 250 |
CFM @ 0.500-In. SP: 150 |
dBA @ 5 Feet: 54 |
Max. Inlet Temp. (Deg. F): 140 |
Max. Ambient Temp. (F): 102 |
Voltage: 115/230 |
Hz: 50/60 |
Phase: 1 |
Full Load Amps: 6.6/3.3 |
Motor HP: 1/3 |
Motor RPM: 1725 |
Motor Type: Hazardous Location, Capacitor Run |
Motor Enclosure: Totally Enclosed Fan Cooled |
Motor Frame: 71 |
Bearing Type: Ball |
Shaft Dia. (In.): 14 mm |
Height (In.): 16.13 |
Width (In.): 14.16 |
Depth (In.): 18.82 |
Inlet Dia. (In.): 4.92 |
Outlet Dia. (In.): 4.92 |
Wheel Type: Forward Curve |
Wheel Material: Polypropylene |
Blower RPM: 1725 |
Rotation: CCW |
Housing Material: Gray and Green Polypropylene |
Agency Compliance: Motors are UL Listed and CSA Certified |
Applications, Comments: Designed to Exhaust Fumes from Highly Corrosive Environments Such as Laboratories, Chemical Plants and Hospitals |
Includes: Hazardous Location Motor for Class I Group D, Class II Groups F and G, Division 1 and Division 2 and Motor Mounting Base |
Дополнительные аксессуары: | ||||
Артикул Каталог |
Наименование |
Описание | Производитель № модели |
|
---|---|---|---|---|
3MRC1 Grainger |
Weather Hood, Height 21.65 In, Width 15.74 In, Depth 14.87 In, Purple Polypropylene Construction Material, Includes Mounting Hardware, Protects Motor Against Weather, For Use With 3MPU7 to 3MPU9, 3MPV1 to 3MPV9, 3MPW1 to 3MPW9, 3MPX1 | PLASTEC WH3 |
Альтернативная продукция:
Blower, Hazardous Location, Direct Drive Forward Curve, Wheel Dia 5.9 In, CFM @ 0.500-In SP 550, CFM @ 0.750-In SP 540, 72 dBA @ 5 Feet, Max Inlet Temp 140 Deg F, Voltage 115/230, 50/60 Hz, 1 Phase, Full Load Amps 6.6/3.3, Motor HP 1/2, Height 16.13 In, Width 14.16 In, Depth 18.82 In, Inlet Dia 4.92 In, Outlet Dia 4.92 In, Housing Material Polypropylene, Includes Hazardous Location Motor for Class I Group D, Class II Groups F and G, Division 1 and Division 2