3HFH7 SER5504N
FANTECH
Energy Recovery Ventilator.120V, 1022 CFM
Energy Recovery Ventilator, Fixed Plate Enthalpy Core, Latent and Sensible Transfer, Number of Speeds 3, CFM @ 0.100-In SP 1022, @ 0.200-In. SP 982, 69% Efficiency, Voltage 120, 60 Hz, 1 Phase, 11 Max Amps, Max Inlet Temp 140 Deg F, Control Method Low, Med Standby Toggle Switch, External Low Voltage Dry Contacts for Remote Controls, Height 24 In, Width 51 7/16 In, Length 36 5/16 In, Number of Inlets 2, Number of Outlets 2
Артикул:
3HFH8
Каталог:
Grainger
Производитель:
FANTECH
Номер модели:
SER8504N
Страна производства:
Canada
Вес (кг):
132.73
Спецификация:
Item: Energy Recovery Ventilator |
Type: Fixed Plate Enthalpy Core, Latent and Sensible Transfer |
Number of Speeds: 3 |
CFM @ 0.100-In. SP: 1022 |
CFM @ 0.200-In. SP: 982 |
CFM @ 0.300-In. SP: 942 |
CFM @ 0.400-In. SP: 902 |
CFM @ 0.500-In. SP: 862 |
CFM @ 0.600-In. SP: 822 |
CFM @ 0.700-In. SP: 783 |
CFM @ 0.800-In. SP: 743 |
CFM @ 0.900-In. SP: 703 |
CFM @ 1.000-In. SP: 663 |
Efficiency: 69% |
Voltage: 120 |
Hz: 60 |
Phase: 1 |
Max. Amps: 11 |
Sensible Effectiveness (@ 32 F): 69% |
Total Recovery Efficiency (@ 95 F): 42% |
Latent Effectiveness (@ 95 F): 34% |
Wiring Method: Hard Wired |
Motor Type: Totally Enclosed Motorized Impellers |
Max. Inlet Temp. (Deg. F): 140 |
Control Method: Low, Med Standby Toggle Switch, External Low Voltage Dry Contacts for Remote Controls |
Remote Control: 3HFJ2 or 3HFJ3 |
Height (In.): 24 |
Width (In.): 51-7/16 |
Length (In.): 36-5/16 |
Number of Inlets: 2 |
Number of Outlets: 2 |
Remarks: All Duct Connections are 8 X 20" |
Mounting Location: Indoor |
Housing Material: 20 Gauge G90 Galvanized Steel with Antique White Baked Powder Coat |
Manufacturers Warranty Length: 3 Years Parts Including Motors and 5 Years on Energy Recovery Core |
Agency Compliance: cCSAus Listed, AHRI Certified |
Альтернативная продукция:
Energy Recovery Ventilator, Fixed Plate Enthalpy Core, Latent and Sensible Transfer, Number of Speeds 3, CFM @ 0.100-In SP 612, @ 0.200-In. SP 585, 71% Efficiency, Voltage 120, 60 Hz, 1 Phase, 5.5 Max Amps, Max Inlet Temp 140 Deg F, Control Method Low, Med Standby Toggle Switch, External Low Voltage Dry Contacts for Remote Controls, Height 24 In, Width 36 5/16 In, Length 36 5/16 In, Number of Inlets 2, Number of Outlets 2
Energy Recovery Ventilator, Fixed Plate Enthalpy Core, Latent and Sensible Transfer, Number of Speeds 3, CFM @ 0.100-In SP 1250, @ 0.200-In. SP 1210, 62% Efficiency, Voltage 120, 60 Hz, 1 Phase, 10.8 Max Amps, Max Inlet Temp 140 Deg F, Control Method Low, Med Standby Toggle Switch, External Low Voltage Dry Contacts for Remote Controls, Height 35 In, Width 51 7/16 In, Length 25 3/4 In, Number of Inlets 2, Number of Outlets 2