Blower, Inline Duct
Inline Belt Drive Duct Blower, Wheel Diameter 10-1/4 Inches, Height 18 Inches, Width 21 Inches, Depth 23 Inches, Without Motor And Drives, Recommended Motor Power Range 1/4 Thru 3/4 HP, Maximum Ambient Temperature 40 Degrees C, Uses Optional 3F538 Filter Rack
Артикул:
3F532
Каталог:
Grainger
Производитель:
DELHI
Номер модели:
209 INSL
Страна производства:
Canada
Вес (кг):
27.32
Спецификация:
Item: Blower |
Type: Less Drive Package |
Wheel Dia. (In.): 10-1/4 |
CFM Range: 1385 to 2115 @ 0.0" SP |
Max. Ambient Temp. (F): 140 |
Max. Inlet Temp. (Deg. F): 140 |
Motor HP Range: 1/4 to 3/4 |
RPM Range: 690 to 1008 |
Bearing Type: Ball |
Height (In.): 18 |
Width (In.): 21 |
Max. Depth (In.): 23 |
Discharge Height (In.): 10-1/4 |
Discharge Width (In.): 11-3/16 |
Number of Mounting Points: 4 |
Bolt Hole Dia. (In.): 7/8 |
Mounting Position: All With Shaft Horizontal |
Wheel Type: Forward Curve |
Wheel Material: Steel |
Shaft Dia. (In.): 3/4 |
Housing Material: Steel |
Housing Finish: Green Baked Enamel |
Filter Height (In.): 16 3/4 |
Filter Width (In.): 1 7/8 |
Filter Factor: 0.055 |
Filter Rack Stock No.: 3F538 |
Дополнительные аксессуары: |
Артикул Каталог |
Наименование |
Описание |
Производитель № модели |
3F538 Grainger |
 |
Filter Rack, Overall Height 18 Inches, Overall Width 21 Inches, Overall Depth Including Flanges 4 Inches, Filter Factor 0.055, Filter Height 16 3/4 Inches, Filter Width 19 7/8 Inches, Drawer Type, For Use With 3F532 Inline Duct Blower |
DELHI F209A |
4PU53 Grainger |
 |
Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 125/52 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire |
DAYTON 4PU53 |
4PU54 Grainger |
 |
Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 165/74 F/C, Temp Differential 25 F, Full Load Amps @120V 9.8, @240V 4.9, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire |
DAYTON 4PU54 |
4PU55 Grainger |
 |
Noncycling Firestat/Limit Control, Switch Action Manual Reset, Open On Rise, Element Insertion Length 5 In, Fixed Cut Out Temp 200/93 F/C, Temp Differential 25 F, Full Load Amps @120V 4.9, @240V 9.8, Height 4 In, Width 3 1/2 In, Depth 6 3/4 In, Protect Against Air Conditioning and Ventilation System Fire Hazards by Breaking Line Voltage Circuit to Blower if Circulated Air Reaches Temperature Indicative of Fire |
DAYTON 4PU55 |