Automtc Standby Generator, Liq, NG/Propane

Automatic Standby Generator, 25 LP/25 NG kW, 31.25 kVA Rating, Voltage 120/208, Height 33-1/2 In.Length 62-3/16 In., Enclosure Material Steel, Fuel Type Natural Gas/Propane, Generac Engine Brand, Engine Size 1.5L, Engine RPM 3600, Amps 87, NG Consumption @ Half Load 430 cu. ft./hr., LP Consumption @ Half Load 4.7 gph, 60 Hz, Sound Level dBA 59 Exercising At 7m or 72 Normal Operation At 7m, Automatic Volts Regulation Yes, Battery Included No, 12VDC Battery Charger Yes, Battery Requirements 26
Артикул:
2ZNF6
Каталог:
Grainger
Производитель:
GENERAC
Номер модели:
QT02515GNSX
Страна производства:
USA
Вес (кг):
454.55
2ZNF6 Automtc Standby Generator, Liq, NG/Propane
Спецификация:
Item: Automatic Standby Generator
Engine Cooling Method: Liquid
kW: 25 LP/25 NG
kVA Rating: 31.25
Voltage: 120/208
Height: 33-1/2"
Length: 62-3/16"
Enclosure Material: Steel
Fuel Type: Natural Gas/Propane
Engine Brand: Generac
Engine Size: 1.5L
Engine RPM: 3600
Amps: 87
NG Consumption @ Half Load: 430 cu. ft./hr.
LP Consumption @ Half Load: 4.7 gph
Hz: 60
Sound Level dBA: 59 Exercising At 7m or 72 Normal Operation At 7m
Automatic Volts Regulation: Yes
Battery Included: No
12VDC Battery Charger: Yes
Battery Requirements: 26
Engine (Block Heater): Optional
Fault Indicator Lights: Yes
Fuel NPT Pipe Connection Sz.: 3/4"
High Temp. Alarm: Yes
Low Coolant Level Alarm: Yes
Low Oil Pressure Alarm: Yes
Main Circuit Breaker: Yes
Min. Gas Pressure @ Generator (In WC): 5 to 14
Over Crank Protection: Yes
Phase: 3
Power Factor: 0.8
Repeat of Exercise Cycle: 7
Run Time Hour Meter: Yes
Over Speed: Yes
Standards: UL cUL, CSA, NEMA, EGSA

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
2ZNW4
Grainger
Подробнее... Generator Engine Block Heater, For Use With Generac Guardian Series, Includes Block Heater and Associated Mounting Hardware GENERAC
5615
2ZNX2
Grainger
Подробнее... Generator Battery Warmer, For Use With Generac Liquid-Cooled Series, Includes 28 In. Battery Warmer GENERAC
5629
2ZNX9
Grainger
Подробнее... Base Plug KitBlack, Includes 4 Base Plugs, Instructions, For Use With Mfg. Model 5518, 5883, 5884, 5885, 5886, 5887 GENERAC
5651
3HFD2
Grainger
Подробнее... Automatic Transfer Switch, Voltage 208, Phase 3, NEMA Enclosure Type 3R, Max. Wattage 20000, Load Transition Type Open, Standard Installation, Max. Amps 100, Height 24-1/8 In., Width 20-1/8 In., Depth 7 In., Enclosure Material Aluminum, 2-Wire Start No, Warranty 2 yr., Automatic Exerciser No, Gray, For Use With 22 to 27kWLockable No, Manual Override YesMax. Wire Size 2/0-14 AWG, Repeat of Exercise Cycle 7, Sensing Generator Hz No, Sensing Line Failure 0.9, Sensing Under Volts 0.6 GENERAC
RTSN100G3
3HFD3
Grainger
Подробнее... Automatic Transfer Switch, Voltage 208, Phase 3, NEMA Enclosure Type 3R, Max. Wattage 45000, Load Transition Type Open, Standard Installation, Max. Amps 200, Height 24 In., Width 20-1/8 In., Depth 7 In., Enclosure Material Aluminum, 2-Wire Start No, Warranty 2 yr., Automatic Exerciser No, Gray, For Use With 20 to 48kWLockable No, Manual Override YesMax. Wire Size 400 MCMSensing Generator Hz No, Sensing Line Failure 0.9, Sensing Under Volts 0.6, Time Delay Neutral No, Time Delay Retransfer Yes GENERAC
RTSN200G3
Обратите внимание:
21AC75
Generator, 1 Phase, 120/240V
6EZX3
Auto Standby Generator, Liquid, 120/240V
6EZY4
Auto Standby Generator, Liq, 277/480V
6FRZ3
Auto Standby Generator, Liq, 120/240V