Energy Recovery Vent, CFM 693/865, 115 V

Energy Recovery Ventilator, 2 Speed, Direct Drive, Enthalpy Wheel Dia 25 In, CFM @ 0.125-In SP 693/865, Total Effectiveness 73.9/70.5 %) @ 0.125-In S, Cooling Reduction 2.5/3.0 Tons) @ 0.125-In S, Heating Reduction 40, 000/47, 000 BtuH) @ 0.125-In S, Sones @ 0.250-In SP @ 5 Ft 5.9/6.5, Max Inlet Temp 105 Deg F, 115 Voltage, 60 Hz, 1 Phase, Min Circuit Amps 18.3, Motor HP 1/3, Housing Height 22 In, Housing Width 36 In, Housing Length 46 In, Indoor Mounting Location
Артикул:
2RB85
Каталог:
Grainger
Производитель:
DAYTON
Номер модели:
2RB85
Страна производства:
USA
Вес (кг):
150.45
2RB85 Energy Recovery Vent, CFM 693/865, 115 V
Спецификация:
Item: Energy Recovery Ventilator
Type: 2 Speed, Direct Drive
Blower Wheel Dia. (In.): 10
Enthalpy Wheel Dia. (In.): 25
CFM @ 0.125-In. SP: 693/865
CFM @ 0.250-In. SP: 678/854
CFM @ 0.375-In. SP: 657/842
CFM @ 0.500-In. SP: 631/825
CFM @ 0.625-In. SP: 598/807
CFM @ 0.750-In. SP: 561/786
CFM @ 0.875-In. SP: 527/763
CFM @ 1.000-In. SP: 497/733
Total Effectiveness (%) @ 0.125-In. SP: 73.9/70.5
Total Effectiveness (%) @ 0.250-In. SP: 74.2/70.7
Total Effectiveness (%) @ 0.375-In. SP: 74.7/70.9
Total Effectiveness (%) @ 0.500-In. SP: 75.3/71.1
Total Effectiveness (%) @ 0.625-In. SP: 76.0/71.3
Total Effectiveness (%) @ 0.750-In. SP: 76.9/71.7
Total Effectiveness (%) @ 0.875-In. SP: 77.6/72.3
Total Effectiveness (%) @ 1.00-In. SP: 78.3/72.9
Cooling Reduction (Tons) @ 0.125-In. SP: 2.5/3.0
Cooling Reduction (Tons) @ 0.250-In. SP: 2.5/3.0
Cooling Reduction (Tons) @ 0.375-In. SP: 2.4/3.0
Cooling Reduction (Tons) @ 0.500-In. SP: 2.4/2.9
Cooling Reduction (Tons) @ 0.625-In. SP: 2.2/2.8
Cooling Reduction (Tons) @ 0.750-In. SP: 2.1/2.8
Cooling Reduction (Tons) @ 0.875-In. SP: 2.0/2.7
Cooling Reduction (Tons) @ 1.00-In. SP: 1.9/2.6
Heating Reduction (BtuH) @ 0.125-In. SP: 40,000/47,000
Heating Reduction (BtuH) @ 0.250-In. SP: 39,000/47,000
Heating Reduction (BtuH) @ 0.375-In. SP: 38,000/46,000
Heating Reduction (BtuH) @ 0.500-In. SP: 37,000/46,000
Heating Reduction (BtuH) @ 0.625-In. SP: 35,000/45,000
Heating Reduction (BtuH) @ 0.750-In. SP: 34,000/44,000
Heating Reduction (BtuH) @ 0.875-In. SP: 32,000/43,000
Heating Reduction (BtuH) @ 1.00-In. SP: 30,000/42,000
Sones @ 0.250-In. SP @ 5 Ft.: 5.96.5
Max. Inlet Temp. (Deg. F): 105
Voltage: 115
Hz: 60
Phase: 1
Min. Circuit Amps: 18.3
Motor HP: 1/3
Motor RPM: 1250/1550
Motor Type: Permanent Split Capacitor
Speed Controllable: Yes
Speed Controller: 1DGV3 ( 2 Required )
Housing Height (In.): 22
Housing Width (In.): 36
Housing Length (In.): 46
Indoor Air Intake Height (In.): 7
Indoor Air Intake Width (In.): 18
Indoor Air Discharge Height (In.): 10
Indoor Air Discharge Width (In.): 9
Outdoor Air Intake Height (In.): 7
Outdoor Air Intake Width (In.): 18
Outdoor Air Discharge Height (In.): 10
Outdoor Air Discharge Width (In.): 9
Mounting Location: Indoor
Housing Material: Galvanized Steel
Energy Recovery Wheel: Polymer Wheel With Silica Gel Desiccant
Agency Compliance: ETL US/Canada
Green Environmental Attribute: Product Contributes To Reducing Energy Consumption
Альтернативная продукция:
2RB84  2RB84
DAYTON
Energy Recovery Ventilator, 2 Speed, Direct Drive, Enthalpy Wheel Dia 19 In, CFM @ 0.125-In SP 395/542, Total Effectiveness 61.9/52.0 %) @ 0.125-In S, Cooling Reduction 1.2/1.4 Tons) @ 0.125-In S, Heating Reduction 19, 000/22, 000 BtuH) @ 0.125-In S, Sones @ 0.250-In SP @ 5 Ft 2.6/3.6, Max Inlet Temp 105 Deg F, 115 Voltage, 60 Hz, 1 Phase, Min Circuit Amps 13.8, Motor HP 1/4, Housing Height 18 In, Housing Width 29 In, Housing Length 40 In, Indoor Mounting Location