ТЕЛ:+7 (985) 487-07-35
WhatsApp / Telegram: +7 (916) 211-71-00
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Motor Starter, NEMA Sz 3, 3P, 120V, 90A

Motor Starter, NEMA, Reversing, NEMA Size 3, Coil Volts 120, 50/60 Hz, Number of Poles 3, 90 Amps AC, Aux Contact Configuration 1 NO, 25 HP @ 3 Phase - 208V, 30 HP @ 3 Phase - 230V, 50 HP @ 3 Phase - 460V, 50 HP @ 3 Phase - 575V, Height 7.97 In, Width 12.72 In, Depth 7.00 In, UL/ CSA, Includes Class 20 Solid State Ambient-Compensated Overload Relay and Instantaneous Magnetic Trip Mechanism
Артикул:
2MMG4
Каталог:
Grainger
Производитель:
SQUARE D
Номер модели:
8736SEO2V02H30S
Страна производства:
Not Available
Вес (кг):
17.70
2MMG4 Motor Starter, NEMA Sz 3, 3P, 120V, 90A
Спецификация:
Item: Motor Starter
Type: NEMA
Starter Type: Reversing
NEMA Size: 3
Coil Volts: 120VAC
Hz: 50/60
Number of Poles: 3
Amps AC: 90
HP @ 3 Phase - 208V: 25
HP @ 3 Phase - 230V: 30
HP @ 3 Phase - 460V: 50
HP @ 3 Phase - 575V: 50
Height (In.): 7.97
Width (In.): 12.72
Depth (In.): 7.00
Aux. Contact Configuration: 1NO
NEMA Enclosure Type: Open
Standards: UL/ CSA
Includes: Class 20 Solid State Ambient-Compensated Overload Relay and Instantaneous Magnetic Trip Mechanism

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
1H572
Grainger
Подробнее... Magnetic Contactor/Starter Contact Kit, Starter Size 3, Three Poles SQUARE D
9998SL7
1H577
Grainger
Подробнее... Circuit Fuse Holder, Starter Size All, For NEMA 00-7 Starter/Contactor, Single Fuse Unit SQUARE D
9999SF3
1H578
Grainger
Подробнее... Circuit Fuse Holder, Starter Size All, For NEMA Starter/Contactor, Two Fuse Unit SQUARE D
9999SF4
1H588
Grainger
Подробнее... Suppression Module, Starter Size 3-5, For Transient Usage Voltages SQUARE D
9999ST2
1H591
Grainger
Подробнее... Auxiliary Contact, Starter Size 00-5, For Use With Starter Type SA and SG, With 1 Normally Open Contact, External Field Convertible SQUARE D
9999SX6
Альтернативная продукция:
2MMG7  8736SFO3V02H30S
SQUARE D
Motor Starter, NEMA, Reversing, NEMA Size 4, Coil Volts 120, 50/60 Hz, Number of Poles 3, 135 Amps AC, Aux Contact Configuration 1 NO, 40 HP @ 3 Phase - 208V, 50 HP @ 3 Phase - 230V, 100 HP @ 3 Phase - 460V, 100 HP @ 3 Phase - 575V, Height 11.69 In, Width 14.25 In, Depth 7.00 In, UL/ CSA, Includes Class 20 Solid State Ambient-Compensated Overload Relay and Instantaneous Magnetic Trip Mechanism

2PXH3  8736SEO2V02S
SQUARE D
Motor Starter, NEMA, Reversing, NEMA Size 3, Coil Volts 120, 50/60 Hz, Number of Poles 3, 90 Amps AC, 25 HP @ 3 Phase - 208V, 30 HP @ 3 Phase - 230V, 50 HP @ 3 Phase - 460V, 50 HP @ 3 Phase - 575V, 18.00 Height (In), Width 13.80 In, Depth 9.80 In, Aux Contact Configuration 1 NO/1 NC, Standards UL/ CSA, Includes Melting Alloy Thermal Overload Relay and Instantaneous Magnetic Trip Mechanism

6HGT2  AN59KN0A5E100
EATON
Motor Starter, NEMA, Reversing, NEMA Size 3, NEMA Enclosure Type Open, Coil Volts 120, 50/60 Hz, Number of Poles 3, 90 Amps AC, Aux. Contact Configuration 1NO, 25 HP @ 3 Phase - 208V, 30 HP @ 3 Phase - 230V, 50 HP @ 3 Phase - 460V, 50 HP @ 3 Phase - 575V, Height (In.) 9.13, Width (In.) 12.13, Depth (In.) 14.50, Standards UL/ CSA, Includes Class 20 Solid State Ambient-Compensated Overload Relay and Instantaneous Magnetic Trip Mechanism