1W499 80I-110S
FLUKE
AC/DC Clamp On Current Probe, 30mA to 20A
AC/DC Clamp On Current Probe, Amps AC 30mA to 20A, AC Frequency Response 100 kHz, Amps DC 30mA to 30A, Jaw Capacity 3/4 In. (19mm), Max. Conductor Size 3/4 In., Connector Type BNC, For Use With Oscilloscopes, DMMs, Output 100mV/A, Accuracy +/-1 Percent of Reading, Safety Rating CAT III 300 V, Includes Instructions, Manufacturers Warranty Length 1 yr.
Артикул:
2ATY3
Каталог:
Grainger
Производитель:
FLUKE
Номер модели:
I30S
Страна производства:
China
Вес (кг):
0.34
Спецификация:
Item: AC/DC Clamp On Current Probe |
Amps AC: 30mA to 20A |
AC Frequency Response: 100 kHz |
Amps DC: 30mA to 30A |
Jaw Capacity: 3/4" (19mm) |
Max. Conductor Size: 3/4" |
Connector Type: BNC |
For Use With: Oscilloscopes, DMMs |
Output: 100mV/A |
Accuracy: +/-1% of Reading |
Safety Rating: CAT III 300 V |
Includes: Instructions |
Manufacturers Warranty Length: 1 yr. |
Дополнительные аксессуары: | ||||
Артикул Каталог |
Наименование |
Описание | Производитель № модели |
|
---|---|---|---|---|
2HYJ7 Grainger |
Battery, Battery Size 9V, Battery Type Alkaline, Voltage 9, Package Quantity 4 | DURACELL MN16RT4Z |
||
3VY99 Grainger |
Battery, Battery Size 9V, Battery Type Alkaline, Voltage 9, Package Quantity 2 | DURACELL MN1604B2Z |
||
4TAE6 Grainger |
Battery, Battery Size 9V, Battery Type Alkaline, Voltage 9V, Standards IEC60086/ANSI, Package Quantity 4 | GRAINGER APPROVED VENDOR 4TAE6 |
||
5LE24 Grainger |
Battery, Battery Size 9V, Battery Type Alkaline, Voltage 9, Standards Mercury Free, Package Quantity 12 | DURACELL PC1604BKD |
Альтернативная продукция:
AC/DC Clamp On Current Probe, Amps AC 0.1 to 100A, AC Frequency Response 100 kHz, Amps DC 0.1 to 100A, Jaw Capacity 1/2 In. (11.8mm)Connector Type BNC, For Use With Oscilloscope, Output 10, 100mV/A, Accuracy 3 Percent of Reading, DC to 1 KHz, Safety Rating CAT II 600 V, CAT III 300 VManufacturers Warranty Length 1 yr.
AC/DC Clamp On Current Probe, Amps AC 300A, AC Frequency Response 20 kHz, Amps DC 450A, Jaw Capacity 3/4 In. (19mm), Max. Conductor Size 3/4 In., Connector Type BNC, For Use With Oscilloscopes, Power Quality Analyzers, DMMs, Output 10, 1mV/A, Accuracy +/-1 Percent of Reading, Safety Rating CAT III 300 V, Includes Instructions, Manufacturers Warranty Length 1 yr.
AC/DC Clamp On Current Probe, Amps AC 30mA to 20A, AC Frequency Response 20 kHz, Amps DC 30mA to 30A, Jaw Capacity 3/4 In. (19mm), Max. Conductor Size 3/4 In., Connector Type Banana Plugs, For Use With DMMs, Output 100mV/A, Accuracy +/-1 Percent of Reading +/-2 mA, Safety Rating CAT III 300 V, Includes Instructions, Manufacturers Warranty Length 1 yr.