ТЕЛ:+7 (985) 487-07-35
WhatsApp / Telegram: +7 (916) 211-71-00
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

AC Adj Frequency Drive, 3 HP, 3 Ph, 230V

AC Drive, Adjustable Frequency, Max HP 3, Max Output Amps 11.0, 200-230 Voltage Input, 200-230 Voltage Output, Input Phase AC 3, Output Phase AC 3, Starting Torque 200 %, Torque @ 1 Hz 200 %, Frequency Setting 50/60 Hertz, Output Frequency 0-400 Hertz, Acceleration Adjust 0.1-3000 Sec, Deceleration Adjust 0.1-3000 Sec, Dynamic Braking, Open Enclosure, Height 4 1/2 In, Width 5 1/8 In, Depth 6 1/8 In, Agency Compliance cULus, CE
Артикул:
1KBR4
Каталог:
Grainger
Производитель:
DAYTON
Номер модели:
1KBR4
Страна производства:
South Korea
Вес (кг):
2.09
1KBR4 AC Adj Frequency Drive, 3 HP, 3 Ph, 230V
Спецификация:
Item: AC Drive
Drive Type: Adjustable Frequency
Max. HP: 3
Max. Output Amps: 11.0
Voltage: 200-230
Voltage Output: 200-230
Input Phase AC: 3
Output Phase AC: 3
Starting Torque (%): 200
Torque @ 1 Hz (%): 200
Frequency Setting (Hertz): 50/60
Output Frequency (Hertz): 0 to 400
Acceleration Adjust (Sec.): 0.1 - 3000
Deceleration Adjust (Sec.): 0.1 - 3000
Dynamic Braking: Yes
Enclosure: Open
Height (In.): 4.5
Width (In.): 5.13
Depth (In.): 6.13
Functions: Multispeed Operation, Operation Mode Selection (V/F Control or Sensorless Vector Control Method Selection Programmable), DC Braking, Dynamic Braking, Upper/Lower Frequency Setting, Frequency Jump Operation, PID Control, Automatic Voltage Regulation, Forward/Reverse/Run, Acceleration/Deceleration (Linear, S-Curve or U-Curve Pattern Selectable), Instantaneous Power Failure Restart Operation, Electronic Thermal Level Adjustment, Retry Function, Trip History Monitor, Auto Tuning, Torque Boost, Overload Advance Notice Signal, Software Lock, Carrier Frequency Adjustment, RS485 Link Operation, Starting Frequency Adjustment, Jogging Operation
Control Type: Keypad/Potentiometer
Key Pad Lockout: Yes
Start/Stop Control: Programmable
Protection: Overcurrent, Overvoltage, Undervoltage, Output Short Circuit, Temperature Abnormality, Overload Shut-Off (Electronic Thermal), Ground Fault Protection, External Trip, Communication Error, Unattended Start Prevention Error, EEPROM Error
Control Method: Space Vector PWM Control
Displays: LED
Digital Readout: RPM, Output Frequency, Output Current, Output Voltage, Operation Direction, PID Feedback, Terminal Input, Terminal Output, Transition Frequency Monitor, Power Consumption and Operating Time Accumulation
For Use With: 3-Phase Inverter Duty Motors
Agency Compliance: cULus, CE
Green Environmental Attribute: Product Contributes To Reducing Energy Consumption

Дополнительные аксессуары:
Артикул
Каталог
Наименование
Описание Производитель
№ модели
4XJL5
Grainger
Подробнее... Output Filter, dV/dT, Voltage 600V & Below, Amps 12, HP 7.5, Phase Three, Enclosure Type UL Type 1, Watts Loss 95, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is 100 Ft. to 1000 Ft., Height 9 In., Width 5.5 In., Depth 10 In., Standards UL Listed, CE certified V1K FILTERS
V1K12A01
4XJR4
Grainger
Подробнее... Input Line Reactor, Low Z, Voltage 208/240, Amps 10.6, 3 HP, Three Phase, Enclosure Type UL Type 1, Watts Loss 29, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuissance Tripping and Reduce Harmonics, Input to VFD, Height 12.25 In., Width 12.5 In., Depth 6.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA28LE01
4XRL3
Grainger
Подробнее... Input Line Reactor, Low Z, Voltage 208/240, Amps 10.6, HP 3, Phase Three, Enclosure Type Open, Watts Loss 29, Impedance 3%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 4 In., Width 4.18 In., Depth 3.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA28L
4XRP6
Grainger
Подробнее... Input Line Reactor, High Z, Voltage 208/240, Amps 10.6, HP 3, Phase Three, Enclosure Type Open, Watts Loss 43.1, Impedance 5%, Features Optimized VFD Protection, Function Eliminate AC Drive Nuisance Tripping and Reduce Harmonics, Application Input to VFD, Height 4 In., Width 4.18 In., Depth 3.75 In., Standards UL Listed, CE certified KDR-LINE REACTORS
KDRULA28H
4XTV4
Grainger
Подробнее... Output Filter, dV/dT, Voltage 600V & Below, Amps 12, HP 7.5, Phase Three, Enclosure Type Open, Watts Loss 95, Features Increase Motor Life and Performance, Function Reduce Voltage Overshoots and Reflective Wave Due to dV/dT, Application Output of VFD, When Motor Lead Length is 100 Ft. to 1000 Ft., Height 9 In., Width 5.5 In., Depth 7.25 In., Standards UL Listed, CE certified V1K FILTERS
V1K12A00
Обратите внимание:
14H065
Enclosed Drive, Amps 2.1
4UAN4
ACDrive, Var.Freq, 25HP, 34A, 460V, 3PH
4UAP3
ACDrive, Var.Freq, 30HP, 87A, 200-240V, 3PH
5HV49
AC Drive, 10 HP