ТЕЛ:+7 (985) 487-07-35
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Артикул
Каталог
Наименование
Описание Производитель
№ модели
2GYN2
Grainger
Подробнее... Zoning System Kit, Three Zone, Voltage 24 AC, Height 10 3/4 In, Width 12 3/4 In, Depth 1 7/8 In, Output Amps 1.5 VA, Connection Screw Type, Terminal Designations One Of L, C, RH, RC, W1/E, W2, W3/AUX, Y1, Y2, G, O, B, R, T1, T2, Two HUM, DEHUM, VENT, Three M6, M4, M1, Ambient Temp Range -40 to 150 F, Ambient Humidity Range (%) 5 to 95, Power Method 11 VA Nominal, Color Taupe Cover, Olive-Gray Base, Application Communicating Zoning System, For Use With 2GYN6, Includes 3 VisionPRO IAQ HONEYWELL
Y8835A1028
2GYN3
Grainger
Подробнее... Zone Damper, Square Damper, Voltage 24 AC, Height 20 In, Width 24 In, Depth 4 In, Output Amps .32A, Connection 2 Wires, Rotation Angle 90 Deg, Timing (Sec) 30, Ambient Temp Range 40F-140F, Power Method 24 Volts, Application Controls Air Flow In Heating And Cooling Systems, For Use With Forced Air Zoning Control Panels HONEYWELL
ZD20X24
2GYN5
Grainger
Подробнее... Zone Damper, Square Damper, Voltage 24 AC, Height 20 In, Width 22 In, Depth 4 In, Output Amps .32A, Connection 2 Wires, Rotation Angle 90 Deg, Timing (Sec) 30, Ambient Temp Range 40F-140F, Power Method 24 Volts, Application Controls Air Flow In Heating And Cooling Systems, For Use With Forced Air Zoning Control Panels HONEYWELL
ZD20X22
2GYN7
Grainger
Подробнее... Zone Damper, Square Damper, Voltage 24 AC, Height 20 In, Width 20 In, Depth 4 In, Output Amps .32A, Connection 2 Wires, Rotation Angle 90 Deg, Timing (Sec) 30, Ambient Temp Range 40F-140F, Power Method 24 Volts, Application Controls Air Flow In Heating And Cooling Systems, For Use With Forced Air Zoning Control Panels HONEYWELL
ZD20X20
2GYN9
Grainger
Подробнее... Zone Damper, Square Damper, Voltage 24 AC, Height 20 In, Width 18 In, Depth 4 In, Output Amps .32A, Connection 2 Wires, Rotation Angle 90 Deg, Timing (Sec) 30, Ambient Temp Range 40F-140F, Power Method 24 Volts, Application Controls Air Flow In Heating And Cooling Systems, For Use With Forced Air Zoning Control Panels HONEYWELL
ZD20X18
2GYP1
Grainger
Подробнее... Zone Damper, Square Damper, Voltage 24 AC, Height 20 In, Width 16 In, Depth 4 In, Output Amps .32A, Connection 2 Wires, Rotation Angle 90 Deg, Timing (Sec) 30, Ambient Temp Range 40F-140F, Power Method 24 Volts, Application Controls Air Flow In Heating And Cooling Systems, For Use With Forced Air Zoning Control Panels HONEYWELL
ZD20X16
2GYP2
Grainger
Подробнее... Zone Damper, Square Damper, Voltage 24 AC, Height 20 In, Width 14 In, Depth 4 In, Output Amps .32A, Connection 2 Wires, Rotation Angle 90 Deg, Timing (Sec) 30, Ambient Temp Range 40F-140F, Power Method 24 Volts, Application Controls Air Flow In Heating And Cooling Systems, For Use With Forced Air Zoning Control Panels HONEYWELL
ZD20X14
2GYP3
Grainger
Подробнее... Zone Damper, Square Damper, Voltage 24 AC, Height 20 In, Width 12 In, Depth 4 In, Output Amps .32A, Connection 2 Wires, Rotation Angle 90 Deg, Timing (Sec) 30, Ambient Temp Range 40F-140F, Power Method 24 Volts, Application Controls Air Flow In Heating And Cooling Systems, For Use With Forced Air Zoning Control Panels HONEYWELL
ZD20X12
2GYP4
Grainger
Подробнее... Zone Damper, Square Damper, Voltage 24 AC, Height 20 In, Width 10 In, Depth 4 In, Output Amps .32A, Connection 2 Wires, Rotation Angle 90 Deg, Timing (Sec) 30, Ambient Temp Range 40F-140F, Power Method 24 Volts, Application Controls Air Flow In Heating And Cooling Systems, For Use With Forced Air Zoning Control Panels HONEYWELL
ZD20X10
2GYP5
Grainger
Подробнее... Zone Damper, Square Damper, Voltage 24 AC, Height 18 In, Width 8 In, Depth 4 In, Output Amps .32A, Connection 2 Wires, Rotation Angle 90 Deg, Timing (Sec) 30, Ambient Temp Range 40F-140F, Power Method 24 Volts, Application Controls Air Flow In Heating And Cooling Systems, For Use With Forced Air Zoning Control Panels HONEYWELL
ZD18X8