3HFH6
Grainger
Подробнее... Energy Recovery Ventilator, Fixed Plate Enthalpy Core, Latent and Sensible Transfer, Number of Speeds 3, CFM @ 0.100-In SP 285, @ 0.200-In. SP 262, 76% Efficiency, Voltage 120, 60 Hz, 1 Phase, 2.5 Max Amps, Max Inlet Temp 140 Deg F, Control Method Low, Med Standby Toggle Switch, External Low Voltage Dry Contacts for Remote Controls, Height 20 1/2 In, Width 25 3/8 In, Length 27 7/8 In, Number of Inlets 2, Number of Outlets 2 FANTECH
SER3204N
3HFH7
Grainger
Подробнее... Energy Recovery Ventilator, Fixed Plate Enthalpy Core, Latent and Sensible Transfer, Number of Speeds 3, CFM @ 0.100-In SP 612, @ 0.200-In. SP 585, 71% Efficiency, Voltage 120, 60 Hz, 1 Phase, 5.5 Max Amps, Max Inlet Temp 140 Deg F, Control Method Low, Med Standby Toggle Switch, External Low Voltage Dry Contacts for Remote Controls, Height 24 In, Width 36 5/16 In, Length 36 5/16 In, Number of Inlets 2, Number of Outlets 2 FANTECH
SER5504N
3HFH8
Grainger
Подробнее... Energy Recovery Ventilator, Fixed Plate Enthalpy Core, Latent and Sensible Transfer, Number of Speeds 3, CFM @ 0.100-In SP 1022, @ 0.200-In. SP 982, 69% Efficiency, Voltage 120, 60 Hz, 1 Phase, 11 Max Amps, Max Inlet Temp 140 Deg F, Control Method Low, Med Standby Toggle Switch, External Low Voltage Dry Contacts for Remote Controls, Height 24 In, Width 51 7/16 In, Length 36 5/16 In, Number of Inlets 2, Number of Outlets 2 FANTECH
SER8504N
3HFH9
Grainger
Подробнее... Energy Recovery Ventilator, Fixed Plate Enthalpy Core, Latent and Sensible Transfer, Number of Speeds 3, CFM @ 0.100-In SP 1250, @ 0.200-In. SP 1210, 62% Efficiency, Voltage 120, 60 Hz, 1 Phase, 10.8 Max Amps, Max Inlet Temp 140 Deg F, Control Method Low, Med Standby Toggle Switch, External Low Voltage Dry Contacts for Remote Controls, Height 35 In, Width 51 7/16 In, Length 25 3/4 In, Number of Inlets 2, Number of Outlets 2 FANTECH
SER11504N
6XAT8
Grainger
Подробнее... Energy Recovery Ventilator, Static Plate, Number of Speeds 1, CFM @ 0.100-In. SP 86, CFM @ 0.300-In. SP 59, CFM @ 0.400-In. SP 46, Voltage 120, 60 Hz, 1 Phase, 1 Max. Amps, Sensible Effectiveness (@ 32 F) 66 @ 69 CFM, Total Recovery Efficiency (@ 95 F) 42 @ 64 CFM, Wiring Method Power Cord, Motor Type PSC, Max. Inlet Temp. (Deg. F) 122, Control Method Built In Transformer Relay Package, Height (In.) 20-1/8, Width (In.) 25-1/8 SOLER & PALAU
TR70
6XAT9
Grainger
Подробнее... Energy Recovery Ventilator, Static Plate, Number of Speeds 1, CFM @ 0.100-In. SP 148, CFM @ 0.300-In. SP 132, CFM @ 0.400-In. SP 113, 94 CFM @ 0.500-In. SP, 69 CFM @ 0.600-In. SP, 52 CFM @ 0.700-In. SP, Voltage 120, 60 Hz, 1 Phase, 1.3 Max. Amps, Sensible Effectiveness (@ 32 F) 72 @ 124 CFM, Total Recovery Efficiency (@ 95 F) 46 @ 126 CFM, Wiring Method Power Cord, Motor Type PSC, Max. Inlet Temp. (Deg. F) 122, Control Method Built In Transformer Relay Package SOLER & PALAU
TR130
6XAU0
Grainger
Подробнее... Energy Recovery Ventilator, Static Plate, Number of Speeds 1, CFM @ 0.100-In. SP 207, CFM @ 0.300-In. SP 186, CFM @ 0.400-In. SP 176, 168 CFM @ 0.500-In. SP, 149 CFM @ 0.600-In. SP, 122 CFM @ 0.700-In. SP, Voltage 120, 60 Hz, 1 Phase, 1.5 Max. Amps, Sensible Effectiveness (@ 32 F) 78 @ 181 CFM, Total Recovery Efficiency (@ 95 F) 52 @ 180 CFM, Wiring Method Power Cord, Motor Type PSC, Max. Inlet Temp. (Deg. F) 122, Control Method Built In Transformer Relay Package SOLER & PALAU
TR200
6XAU1
Grainger
Подробнее... Energy Recovery Ventilator, Static Plate, Number of Speeds 1, CFM @ 0.400-In. SP 315, 295 CFM @ 0.500-In. SP, 279 CFM @ 0.600-In. SP, 253 CFM @ 0.700-In. SP, CFM @ 0.800-In. SP 202, CFM @ 0.900-In. SP 163, Voltage 120, 60 Hz, 1 Phase, 3.3 Max. Amps, Sensible Effectiveness (@ 32 F) 70 @ 295 CFM, Total Recovery Efficiency (@ 95 F) 43 @ 285 CFM, Wiring Method Power Cord, Motor Type PSC, Max. Inlet Temp. (Deg. F) 122 SOLER & PALAU
TR300