ТЕЛ:+7 (985) 487-07-35
INFO@ROS-MASTER.RU
ИНДУСТРИАЛЬНЫЙ КАТАЛОГ

Артикул
Каталог
Наименование
Описание Производитель
№ модели
6XJU3
Grainger
Подробнее... Pressure Sensing Switch, HVAC/General Purpose, Differential (In. WC) 0.02 to 0.8, Switch Type SPDT, Pressure Setting Range (In. WC) 0.05 to 12.0, Electrical Rating 300 VA Pilot Duty at 115 to 277 VAC, 15 amps Noninductive to 277 VAC, Sample Line Connector Integral Compression, Height (In.) 6-1/8, Width (In.) 3-11/32, Depth (In.) 3-1/4, Mounting Holes O.C. (In.) 3-7/8, Mounting Location Vertical, Includes 2 Slip-On Tubing Adapters and Mounting Screws ROBERTSHAW
2374-500
6XJU4
Grainger
Подробнее... Pressure Sensing Switch, HVAC/General Purpose, Differential (In. WC) 0.02 to 0.8, Switch Type SPDT, Pressure Setting Range (In. WC) 0.05 to 2.0, Electrical Rating 300 VA Pilot Duty at 115 to 277 VAC, 15 amps Noninductive to 277 VAC, Sample Line Connector Integral Compression, Height (In.) 6-1/8, Width (In.) 3-11/32, Depth (In.) 3-1/4, Mounting Holes O.C. (In.) 3-7/8, Mounting Location Vertical, Includes Slip-On 1/4 In OD Tubing Adapter, Sample Line Probes, Orifice Plugs ROBERTSHAW
2374-501
6XJU5
Grainger
Подробнее... Pressure Sensing Switch, HVAC/General Purpose, Differential (In. WC) 0.02 to 0.8, Switch Type SPDT, Pressure Setting Range (In. WC) 0.05 to 12.0, Electrical Rating 300 VA Pilot Duty at 115 to 277 VAC, 15 amps Noninductive to 277 VAC, Sample Line Connector 1/4 In Slip-On, Height (In.) 5-13/16, Width (In.) 3-1/4, Depth (In.) 2-7/8, Mounting Holes O.C. (In.) 3-7/8, Mounting Location Vertical, Includes Slip-On 1/4 In OD Tubing Adapter, Sample Line Probes, Orifice Plugs ROBERTSHAW
2374-502
6XJU6
Grainger
Подробнее... Pressure Sensing Switch, Gold Contacts, Differential (In. WC) 0.02 to 0.8, Switch Type SPDT, Pressure Setting Range (In. WC) 0.05 to 12.0, Electrical Rating 300 VA Pilot Duty at 115 to 277 VAC, 15 amps Noninductive to 277 VAC, Sample Line Connector Integral Compression, Height (In.) 6-1/8, Width (In.) 3-1/4, Depth (In.) 3-1/4, Mounting Holes O.C. (In.) 3-7/8, Mounting Location Vertical, Includes Slip-On 1/4 In OD Tubing Adapter, Sample Line Probes, Orifice Plugs ROBERTSHAW
2374-503
6XJU7
Grainger
Подробнее... Pressure Sensing Switch, Manual Reset, Differential (In. WC) 0.06 to 0.8, Switch Type SPST NC, Pressure Setting Range (In. WC) 0.4 to 12.0, Electrical Rating 15A at 125, 250, or 277 VAC, .5A at 125 VDC, .25A at 250 VDC, Sample Line Connector Integral Compression, Height (In.) 6-1/8, Width (In.) 3-1/4, Depth (In.) 3-1/4, Mounting Holes O.C. (In.) 3-9/16, Mounting Location Vertical, Includes Slip-On 1/4 In OD Tubing Adapter, Sample Line Probes, Orifice Plugs ROBERTSHAW
2374-504
6XJU8
Grainger
Подробнее... Pressure Sensing Switch, Pneumatic Signal Output, Differential (In. WC) 0.15 to 2.0, Pressure Setting Range (In. WC) 0.15 to 2.0, Sample Line Connector Integral Compression, Height (In.) 6-1/8, Width (In.) 3-1/4, Depth (In.) 3-1/4, Mounting Holes O.C. (In.) 2-13/16, Mounting Location Vertical, Includes Slip-On 1/4 In OD Tubing Adapter, Sample Line Probes, Orifice Plugs ROBERTSHAW
2374-505
6XJU9
Grainger
Подробнее... Pressure Sensing Switch, HVAC/General Purpose, Switch Type SPDT, Pressure Setting Range (In. WC) 0.02, Electrical Rating 300 VA Pilot Duty at 115 to 277 VAC, Sample Line Connector 1/4 In Slip-On, Height (In.) 6-1/8, Width (In.) 3-1/4, Depth (In.) 3-1/4, Mounting Holes O.C. (In.) 2-15/16, Mounting Location Vertical, Includes Sample Line Probes, Orifice Plugs ROBERTSHAW
2374-506
6XJV0
Grainger
Подробнее... Pressure Sensing Switch, HVAC/General Purpose, Differential (In. WC) +/- 0.06, Switch Type (2) SPST NC, Pressure Setting Range (In. WC) 0.06 to 0.8, Electrical Rating 15A at 125, 250, or 277 VAC, .5A at 125 V DC, .25A at 250 VDC, 0.5 VA at 24VAC, Sample Line Connector Integral Compression, Height (In.) 6-1/8, Width (In.) 3-1/4, Depth (In.) 3-1/4, Mounting Holes O.C. (In.) 3-9/16, Mounting Location Vertical, Includes Slip-On 1/4 In OD Tubing Adapter, Sample Line Probes, Orifice Plugs ROBERTSHAW
2374-507
6XJV1
Grainger
Подробнее... Pressure Sensing Switch, HVAC/General Purpose, Differential (In. WC) +/- 0.02, Switch Type SPDT, Pressure Setting Range (In. WC) 0.05 to 0.3, Electrical Rating 300 VA Pilot Duty at 115 to 277 VAC, 15 amps Noninductive to 277 VAC, Sample Line Connector Integral Compression, Height (In.) 4-3/32, Width (In.) 4-5/8, Depth (In.) 3, Mounting Holes O.C. (In.) 3-3/4, Mounting Location Vertical, Includes Slip-On 1/4 In OD Tubing Adapter, Sample Line Probes, Orifice Plugs ROBERTSHAW
2374-508
6XJV2
Grainger
Подробнее... Pressure Sensing Switch, HVAC/General Purpose, Differential (In. WC) +/-0.02, Switch Type SPDT, Pressure Setting Range (In. WC) 0.05 to 0.3, Electrical Rating 300 VA Pilot Duty at 115 to 277 VAC, 15 amps Noninductive to 277 VAC, Sample Line Connector Integral Compression, Height (In.) 4-3/32, Width (In.) 4-5/8, Depth (In.) 2-3/4, Mounting Holes O.C. (In.) 3-3/4, Mounting Location Vertical, Includes Slip-On 1/4 In OD Tubing Adapter, Sample Line Probes, Orifice Plugs ROBERTSHAW
2374-509